Objects in TIMETRA-PORT-MIB
OID records
| OID | Name | Description |
|---|---|---|
| 1.3.6.1.4.1.6527.3.1.2.2.4.22.1.10 | tmnxBundleMemberImaNeSevErrSecs | tmnxBundleMemberImaNeSevErrSecs indicates the number of one second intervals in which thirty percent or more of the near-end ICP cells are in violation, or link d… |
| 1.3.6.1.4.1.6527.3.1.1.2.2 | tmnxPortConformance | |
| 1.3.6.1.4.1.6527.3.1.1.2.2.2.36 | tmnxObsoleteGroupV5v0 | The group of objects obsoleted in the 7x50 SR series 5.0 release |
| 1.3.6.1.4.1.6527.3.1.2.2.4.20.1.4 | tmnxCiscoHDLCOperState | The value of tmnxCiscoHDLCOperState indicates the operational status of the Cisco HDLC protocol for this port. |
| 1.3.6.1.4.1.6527.3.1.2.2.4.7.1.4 | tmnxPortTypeStatus | When tmnxPortTypeStatus has a value of 'true' it indicates that this port model is supported in this revision of the management software. When it has a value of… |
| 1.3.6.1.4.1.6527.3.1.2.2.4.22.1.23 | tmnxBundleMemberImaRxIcpCells | tmnxBundleMemberImaRxIcpCells indicates the number of ICP cells that have been received on the IMA link. |
| 1.3.6.1.4.1.6527.3.1.2.2.4.31.1.2 | tmnxDDMTempLowWarning | The value of tmnxDDMTempLowWarning indicates the temperature of the SFP/XFP in degrees Celsius that triggers a low-warning. |
| 1.3.6.1.4.1.6527.3.1.2.2.4.4.1.6 | tmnxPortEtherOperSpeed | The tmnxPortEtherOperSpeed variable indicates the operational speed of the Ethernet interface in mega-bits per second (mbps). If the value of tmnxPortEtherAutoN… |
| 1.3.6.1.4.1.6527.3.1.2.2.4.31.1.40 | tmnxDDMExternallyCalibrated | The value of tmnxDDMExternallyCalibrated indicates whether the SFP was externally calibrated (true) or internally calibrated (false). |
| 1.3.6.1.4.1.6527.3.1.2.2.4.5.1.19 | tmnxSonetJ0String | The tmnxSonetJ0String is used with the tmnxSonetSectionTraceMode variable to determine the contents of the j0 byte in the SONET Section Header. If the tmnxSonetS… |
| 1.3.6.1.4.1.6527.3.1.3.2.2.0.18 | tmnxEqPortDS1AlarmClear | Generated when a DS1 interface alarm condition is cleared. It is generated only when the type of alarm being cleared is enabled in tmnxDS1ReportAlarm. |
| 1.3.6.1.4.1.6527.3.1.2.2.4.17.1.23 | tmnxPortIngrMdaQos11StatDropPkts | tmnxPortIngrMdaQos11StatDropPkts indicates the number of packets dropped on the oversubscribed MDA for given Qos classifier result because of an overload conditi… |
| 1.3.6.1.4.1.6527.3.1.2.2.4.12 | tmnxDS1Table | The tmnxDS1Table has an entry for each DS1 channel. |
| 1.3.6.1.4.1.6527.3.1.2.2.4.19 | tmnxPortScalarObjs | |
| 1.3.6.1.4.1.6527.3.1.1.2.2.1 | tmnxPortCompliances | |
| 1.3.6.1.4.1.6527.3.1.2.2.4.31.1.4 | tmnxDDMTempHiWarning | The value of tmnxDDMTempHiWarning indicates the temperature of the SFP/XFP in degrees Celsius that triggers a hi-warning. |
| 1.3.6.1.4.1.6527.3.1.2.2.4.2.1.63 | tmnxPortEgrPoolPercentRate | The value of tmnxPortEgrPoolPercentRate specifies increment or decrement of the active bandwidth associated with the egress port. This active bandwidth affects t… |
| 1.3.6.1.4.1.6527.3.1.2.2.4.17.1.17 | tmnxPortIngrMdaQos08StatDropPkts | tmnxPortIngrMdaQos08StatDropPkts indicates the number of packets dropped on the oversubscribed MDA for given Qos classifier result because of an overload conditi… |
| 1.3.6.1.4.1.6527.3.1.2.2.4.5.1.15 | tmnxSonetApsHoldTimeLeft | Automatic Protection Switching (APS) is supported on 7x50 systems by the APS-MIB and TIMETRA-APS-MIB. |
| 1.3.6.1.4.1.6527.3.1.2.2.12.2.1.9 | tmnxPortNetEgressDroOutProfOcts | tmnxPortNetEgressDroOutProfOcts indicates the number of exceeding network egress octets dropped on this port using this queue. |
| 1.3.6.1.4.1.6527.3.1.2.2.4.4.1.11 | tmnxPortEtherEgressRate | The tmnxPortEtherEgressRate variable specifies the maximum egress bandwidth (in kilobits per second) that the Ethernet interface can generate. A value of -1 mean… |
| 1.3.6.1.4.1.6527.3.1.2.2.4.22 | tmnxBundleMemberImaTable | The tmnxBundleMemberImaTable has an entry for an IMA link associated with an IMA Group. |
| 1.3.6.1.4.1.6527.3.1.2.2.7 | tmnxPortNotificationObjects | |
| 1.3.6.1.4.1.6527.3.1.2.2.4.26.1.4 | tmnxBundleMlpppIngQoSProfId | tmnxBundleMlpppIngQoSProfId specifies ingress QoS profile to be used for the incoming traffic over this MLPPP bundle. The value of tmnxBundleMlpppIngQoSProfId ma… |
| 1.3.6.1.4.1.6527.3.1.2.2.4.22.1.1 | tmnxBundleMemberImaNeTxState | tmnxBundleMemberImaNeTxState indicates the state of near-end transmit IMA link. |
| 1.3.6.1.4.1.6527.3.1.2.2.7.1 | tmnxPortNotifyPortId | Used by tmnx port Notifications, the OID indicates the port or sonet path associated with the alarm. |
| 1.3.6.1.4.1.6527.3.1.2.2.4.2.1.44 | tmnxPortClearAlarms | Setting this action variable causes all the alarms associated with this port to be moved from the current alarm log to the history alarm log. Primarily meant for … |
| 1.3.6.1.4.1.6527.3.1.1.2.2.1.3.4 | tmnxPortComp7750V6v0 | The compliance statement for revision 6.0 of TIMETRA-PORT-MIB on the Alcatel 7750 SR series systems. |
| 1.3.6.1.4.1.6527.3.1.3.2.2.0.1 | tmnxEqOobPortFailure | Generated when the out-of-band Ethernet port has failed. On the Alcatel 7x50 SR system, the out-of-band port is the CPM management interface. This notification … |
| 1.3.6.1.4.1.6527.3.1.3.2.2.0.4 | tmnxEqPortSonetAlarm | Generated when a SONET/SDH port alarm condition is detected. It is generated only when the type of alarm being raised is enabled in tmnxSonetReportAlarm. |
| 1.3.6.1.4.1.6527.3.1.2.2.4.5.1.5 | tmnxSonetBerSdThreshold | The value of tmnxSonetBerSdThreshold specifies a bit error rate (BER) threshold used to determine when to send a tmnxEqPortSonetAlarm notification for a BER SD f… |
| 1.3.6.1.4.1.6527.3.1.2.2.4.13.1.7 | tmnxDS0ChanGroupLastChangeTime | The tmnxDS0ChanGroupLastChangeTime variable contains the sysUpTime value of the most recently modified writable variable in the tmnxDS0ChanGroupEntry row for thi… |
| 1.3.6.1.4.1.6527.3.1.2.2.4.17.1.9 | tmnxPortIngrMdaQos04StatDropPkts | tmnxPortIngrMdaQos04StatDropPkts indicates the number of packets dropped on the oversubscribed MDA for given Qos classifier result because of an overload conditi… |
| 1.3.6.1.4.1.6527.3.1.2.2.4.13.1.9 | tmnxDS0ChanGroupScramble | tmnxDS0ChanGroupScramble indicates whether payload scrambling is enabled on this ATM channel. Both ends of the connection must use the same scrambling algorithm… |
| 1.3.6.1.4.1.6527.3.1.2.2.4.6.1.17 | tmnxSonetPathChildType | tmnxSonetPathChildType is used to configure the type of this path. Some typical default values are: pdhDs3 for STS-1 paths pdhE3 for TU3 paths pdhE1 for VT2 paths p… |
| 1.3.6.1.4.1.6527.3.1.2.2.4.17.1.28 | tmnxPortIngrMdaQos13StatDropOcts | tmnxPortIngrMdaQos13StatDropOcts indicates the number of octets dropped on the oversubscribed MDA for given Qos classifier result because of an overload conditio… |
| 1.3.6.1.4.1.6527.3.1.2.2.9.1.1.2 | tmnxFRDlcmiN392Dce | tmnxFRDlcmiN392Dce is used to configure the LMI error threshold for DCE interface. |
| 1.3.6.1.4.1.6527.3.1.2.2.4.2.1.40 | tmnxPortPrevState | The tmnxPortPrevState indicates the state level that the port transitioned from into the current tmnxPortState level. |
| 1.3.6.1.4.1.6527.3.1.2.2.4.31.1.44 | tmnxDDMExtCalRxPower1 | The value of tmnxDDMExtCalRxPower1 indicates the Rx_PWR(1) value as specified in Table 3.16 in the SFF Committee Standard's document SFF-8472 Rev 10.2. |
| 1.3.6.1.4.1.6527.3.1.2.2.12.2.1.7 | tmnxPortNetEgressDroOutProfPkts | tmnxPortNetEgressDroOutProfPkts indicates the number of exceeding network egress packets dropped on this port using this queue. |
| 1.3.6.1.4.1.6527.3.1.3.2.2.0.16 | tmnxEqPortDS3AlarmClear | Generated when a DS3 interface alarm condition is cleared. It is generated only when the type of alarm being cleared is enabled in tmnxDS3ChannelReportAlarm. |
| 1.3.6.1.4.1.6527.3.1.2.2.12.2.1.2 | tmnxPortNetEgressFwdInProfPkts | tmnxPortNetEgressFwdInProfPkts indicates the number of conforming network egress packets forwarded on this port using this queue. |
| 1.3.6.1.4.1.6527.3.1.2.2.4.22.1.9 | tmnxBundleMemberImaViolations | tmnxBundleMemberImaViolations indicates the number of ICP violations including errored, invalid or missing ICP cells. |
| 1.3.6.1.4.1.6527.3.1.1.2.2.2.34 | tmnx7710PortTDMGroupV3v0 | The group of objects supporting management of TDM type ports specific to the Alcatel 7710 SR series systems for revision 3.0. |
| 1.3.6.1.4.1.6527.3.1.1.2.2.1.4.4 | tmnxPortComp7450V6v0 | The compliance statement for revision 5.0 of TIMETRA-PORT-MIB on the Alcatel 7450 SR series systems. |
| 1.3.6.1.4.1.6527.3.1.2.2.4.18.1.1 | tmnxSonetGroupType | tmnxSonetGroupType indicates the sonet group type of this entry. For STS-3/STM-1 channelization, the value of this object will be 'sdhTug3'. |
| 1.3.6.1.4.1.6527.3.1.2.2.4.31.1.11 | tmnxDDMTxBiasCurrent | The value of tmnxDDMTxBiasCurrent indicates the current Transmit Bias Current of the SFP/XFP in micro-Amperes (uA). |
| 1.3.6.1.4.1.6527.3.1.2.2.4.12.1.12 | tmnxDS1LastChangeTime | The tmnxDS1LastChangeTime variable contains the sysUpTime value of the most recently modified writable variable in the tmnxDS1Entry row for this channel. |
| 1.3.6.1.4.1.6527.3.1.2.2.4.22.1.15 | tmnxBundleMemberImaNeRxUnuseSecs | tmnxBundleMemberImaNeRxUnuseSecs indicates the number of unavailable seconds at the near-end receive link state machine. |
| 1.3.6.1.4.1.6527.3.1.2.2.4.31.1.22 | tmnxDDMRxOpticalPowerLowWarning | The value of tmnxDDMRxOpticalPowerLowWarning indicates the Received Optical Power of the SFP/XFP in micro-Watts (uW) that triggers a low-warning. |