tmnxBundleMemberImaViolations indicates the number of
ICP violations including errored, invalid or missing ICP
cells.
Parsed from file TIMETRA-PORT-MIB.mib
Module: TIMETRA-PORT-MIB
tmnxBundleMemberImaViolations OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "tmnxBundleMemberImaViolations indicates the number of ICP violations including errored, invalid or missing ICP cells." ::= { tmnxBundleMemberImaEntry 9 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.6527.3.1.2.2.4.22.1.1 | tmnxBundleMemberImaNeTxState | 0 | 0 | tmnxBundleMemberImaNeTxState indicates the state of near-end transmit IMA link. |
1.3.6.1.4.1.6527.3.1.2.2.4.22.1.2 | tmnxBundleMemberImaNeRxState | 0 | 0 | tmnxBundleMemberImaNeRxState indicates the state of near-end receive IMA link. |
1.3.6.1.4.1.6527.3.1.2.2.4.22.1.3 | tmnxBundleMemberImaFeTxState | 0 | 0 | tmnxBundleMemberImaFeTxState indicates the state of far-end transmit IMA link. |
1.3.6.1.4.1.6527.3.1.2.2.4.22.1.4 | tmnxBundleMemberImaFeRxState | 0 | 0 | tmnxBundleMemberImaFeRxState indicates the state of far-end receive IMA link. |
1.3.6.1.4.1.6527.3.1.2.2.4.22.1.5 | tmnxBundleMemberImaNeRxFailState | 0 | 0 | tmnxBundleMemberImaNeRxFailState indicates the IMA link failure reason for the near-end. |
1.3.6.1.4.1.6527.3.1.2.2.4.22.1.6 | tmnxBundleMemberImaFeRxFailState | 0 | 0 | tmnxBundleMemberImaFeRxFailState indicates the IMA link failure reason for the far-end. |
1.3.6.1.4.1.6527.3.1.2.2.4.22.1.7 | tmnxBundleMemberImaTxLid | 0 | 0 | tmnxBundleMemberImaTxLid indicates the Link Identifier assigned to the transmit IMA link. |
1.3.6.1.4.1.6527.3.1.2.2.4.22.1.8 | tmnxBundleMemberImaRxLid | 0 | 0 | tmnxBundleMemberImaRxLid indicates the Link Identifier used on the receive IMA link. |
1.3.6.1.4.1.6527.3.1.2.2.4.22.1.10 | tmnxBundleMemberImaNeSevErrSecs | 0 | 0 | tmnxBundleMemberImaNeSevErrSecs indicates the number of one second intervals in which thirty percent or more of the near-end ICP … |
1.3.6.1.4.1.6527.3.1.2.2.4.22.1.11 | tmnxBundleMemberImaFeSevErrSecs | 0 | 0 | tmnxBundleMemberImaFeSevErrSecs indicates the number of one second intervals in which the far-end contains IMA-RDI defects. |
1.3.6.1.4.1.6527.3.1.2.2.4.22.1.12 | tmnxBundleMemberImaNeUnavailSecs | 0 | 0 | tmnxBundleMemberImaNeUnavailSecs indicates the number of unavailable seconds at the near-end. |
1.3.6.1.4.1.6527.3.1.2.2.4.22.1.13 | tmnxBundleMemberImaFeUnavailSecs | 0 | 0 | tmnxBundleMemberImaFeUnavailSecs indicates the number of unavailable seconds at the near-end. |
1.3.6.1.4.1.6527.3.1.2.2.4.22.1.14 | tmnxBundleMemberImaNeTxUnuseSecs | 0 | 0 | tmnxBundleMemberImaNeTxUnuseSecs indicates the number of unavailable seconds at the near-end transmit link state machine. |
1.3.6.1.4.1.6527.3.1.2.2.4.22.1.15 | tmnxBundleMemberImaNeRxUnuseSecs | 0 | 0 | tmnxBundleMemberImaNeRxUnuseSecs indicates the number of unavailable seconds at the near-end receive link state machine. |
1.3.6.1.4.1.6527.3.1.2.2.4.22.1.16 | tmnxBundleMemberImaFeTxUnuseSecs | 0 | 0 | tmnxBundleMemberImaFeTxUnuseSecs indicates the number of unavailable seconds at the far-end transmit link state machine. |
1.3.6.1.4.1.6527.3.1.2.2.4.22.1.17 | tmnxBundleMemberImaFeRxUnuseSecs | 0 | 0 | tmnxBundleMemberImaFeRxUnuseSecs indicates the number of unavailable seconds at the far-end receive link state machine. |
1.3.6.1.4.1.6527.3.1.2.2.4.22.1.18 | tmnxBundleMemberImaNeTxNumFails | 0 | 0 | tmnxBundleMemberImaNeTxNumFails indicates the number of times that a near-end transmit alarm is set on the IMA link. |
1.3.6.1.4.1.6527.3.1.2.2.4.22.1.19 | tmnxBundleMemberImaNeRxNumFails | 0 | 0 | tmnxBundleMemberImaNeRxNumFails indicates the number of times that a near-end receive alarm is set on the IMA link. |
1.3.6.1.4.1.6527.3.1.2.2.4.22.1.20 | tmnxBundleMemberImaFeTxNumFails | 0 | 0 | tmnxBundleMemberImaFeTxNumFails indicates the number of times that a far-end transmit alarm is set on the IMA link. |
1.3.6.1.4.1.6527.3.1.2.2.4.22.1.21 | tmnxBundleMemberImaFeRxNumFails | 0 | 0 | tmnxBundleMemberImaFeRxNumFails indicates the number of times that a far-end receive alarm is set on the IMA link. |
1.3.6.1.4.1.6527.3.1.2.2.4.22.1.22 | tmnxBundleMemberImaTxIcpCells | 0 | 0 | tmnxBundleMemberImaTxIcpCells indicates the number of ICP cells that have been transmitted on the IMA link. |
1.3.6.1.4.1.6527.3.1.2.2.4.22.1.23 | tmnxBundleMemberImaRxIcpCells | 0 | 0 | tmnxBundleMemberImaRxIcpCells indicates the number of ICP cells that have been received on the IMA link. |
1.3.6.1.4.1.6527.3.1.2.2.4.22.1.24 | tmnxBundleMemberImaErrorIcpCells | 0 | 0 | tmnxBundleMemberImaErrorIcpCells indicates the number of ICP cells with HEC or CRC-10 errors. |
1.3.6.1.4.1.6527.3.1.2.2.4.22.1.25 | tmnxBundleMemberImaLstRxIcpCells | 0 | 0 | tmnxBundleMemberImaLstRxIcpCells indicates the number of lost ICP cells at the expected offset. |
1.3.6.1.4.1.6527.3.1.2.2.4.22.1.26 | tmnxBundleMemberImaOifAnomalies | 0 | 0 | tmnxBundleMemberImaOifAnomalies indicates the number of OIF anomalies at the near-end. |
1.3.6.1.4.1.6527.3.1.2.2.4.22.1.27 | tmnxBundleMemberImaRxTestState | 0 | 0 | tmnxBundleMemberImaRxTestState indicates the current state of the test pattern on this link. |
1.3.6.1.4.1.6527.3.1.2.2.4.22.1.28 | tmnxBundleMemberImaRxTestPattern | 0 | 0 | tmnxBundleMemberImaRxTestPattern indicates the received test pattern value on this link. |
1.3.6.1.4.1.6527.3.1.2.2.4.22.1.29 | tmnxBundleMemberImaRelDelay | 0 | 0 | tmnxBundleMemberImaRelDelay indicates the latest measured delay on this member link relative to the member link with the least de… |