Reference record for OID 1.3.111.2.802.1.1.18.1.3


parent
1.3.111.2.802.1.1.18.1 (ieee8021CnMIBObjects)
node code
3
node name
ieee8021CnCompntPriTable
dot oid
1.3.111.2.802.1.1.18.1.3
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) ieee(111) standards-association-numbered-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021CnMib(18) ieee8021CnMIBObjects(1) ieee8021CnCompntPriTable(3)}
  • {iso(1) identified-organization(3) ieee(111) standards-association-numbers-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021CnMib(18) ieee8021CnMIBObjects(1) ieee8021CnCompntPriTable(3)}
  • {iso(1) org(3) ieee(111) standards-association-numbered-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021CnMib(18) ieee8021CnMIBObjects(1) ieee8021CnCompntPriTable(3)}
  • {iso(1) org(3) ieee(111) standards-association-numbers-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021CnMib(18) ieee8021CnMIBObjects(1) ieee8021CnCompntPriTable(3)}
  • {iso(1) iso-identified-organization(3) ieee(111) standards-association-numbered-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021CnMib(18) ieee8021CnMIBObjects(1) ieee8021CnCompntPriTable(3)}
  • {iso(1) iso-identified-organization(3) ieee(111) standards-association-numbers-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021CnMib(18) ieee8021CnMIBObjects(1) ieee8021CnCompntPriTable(3)}
  • iri oid
  • /iso/identified-organization/ieee/standards-association-numbered-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021CnMib/ieee8021CnMIBObjects/ieee8021CnCompntPriTable
  • /iso/identified-organization/ieee/standards-association-numbers-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021CnMib/ieee8021CnMIBObjects/ieee8021CnCompntPriTable
  • /iso/org/ieee/standards-association-numbered-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021CnMib/ieee8021CnMIBObjects/ieee8021CnCompntPriTable
  • /iso/org/ieee/standards-association-numbers-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021CnMib/ieee8021CnMIBObjects/ieee8021CnCompntPriTable
  • /iso/iso-identified-organization/ieee/standards-association-numbered-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021CnMib/ieee8021CnMIBObjects/ieee8021CnCompntPriTable
  • /iso/iso-identified-organization/ieee/standards-association-numbers-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021CnMib/ieee8021CnMIBObjects/ieee8021CnCompntPriTable
  • iri by oid_info
    /ISO/Identified-Organization/111/2/802/1/1/18/1/3

    Description by oid_info

    ieee8021CnCompntPriTable OBJECT-TYPE
    SYNTAX SEQUENCE OF Ieee8021CnCompntPriEntry
    MAX-ACCESS not-accessible
    STATUS current
    DESCRIPTION
    "Each row in this table supplies default values for one
    Congestion Notification Priority Value for a whole bridge
    component or end station.
    Creating a row in this table makes the priority value of
    ieee8021CnComPriPriority a
    Congestion Notification Priority Value.
    Deleting a row in this table makes the value in the deleted
    ieee8021CnComPriPriority no longer a
    Congestion Notification Priority Value.
    A system SHALL NOT allow eight rows in this table
    to be created with the same value of
    ieee8021CnComPriComponentId; see the description of
    ieee8021CnComPriRowStatus.
    The contents of this table SHALL be maintained across a restart
    of the system.
    "
    REFERENCE
    "802.1Qau clause 12.21.2, 12.21.2.1, 12.21.2.2"

    View at oid-info.com

    Description by ieee802

    Each row in this table supplies default values for one
    Congestion Notification Priority Value for a whole bridge
    component or end station.

    Creating a row in this table makes the priority value of
    ieee8021CnComPriPriority a
    Congestion Notification Priority Value.
    Deleting a row in this table makes the value in the deleted
    ieee8021CnComPriPriority no longer a
    Congestion Notification Priority Value.

    A system SHALL NOT allow eight rows in this table
    to be created with the same value of
    ieee8021CnComPriComponentId; see the description of
    ieee8021CnComPriRowStatus.

    The contents of this table SHALL be maintained across a restart
    of the system.

    Information by oid_info

    Automatically extracted from IEEE Management Information Bases (MIBs)

    Information by ieee802

    ieee8021CnCompntPriTable OBJECT-TYPE SYNTAX SEQUENCE OF Ieee8021CnCompntPriEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each row in this table supplies default values for one Congestion Notification Priority Value for a whole bridge component or end station. Creating a row in this table makes the priority value of ieee8021CnComPriPriority a Congestion Notification Priority Value. Deleting a row in this table makes the value in the deleted ieee8021CnComPriPriority no longer a Congestion Notification Priority Value. A system SHALL NOT allow eight rows in this table to be created with the same value of ieee8021CnComPriComponentId; see the description of ieee8021CnComPriRowStatus. The contents of this table SHALL be maintained across a restart of the system. " REFERENCE "802.1Qau clause 12.17.2, 12.17.2.1, 12.17.2.2" ::= { ieee8021CnMIBObjects 3 }

    Current Registration Authority (recovered by parent 1.3)

    Frank Farance

    Children (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.111.2.802.1.1.18.1.3.1 ieee8021CnCompntPriEntry 10 10 One entry per Congestion Notification Priority Value per
    bridge component or end station.

    Brothers (7)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.111.2.802.1.1.18.1.1 ieee8021CnGlobalTable 1 5 A table containing the global variables for each component of
    a bridge or for an end station. A value of 1 is used in a
    bridge o…
    1.3.111.2.802.1.1.18.1.2 ieee8021CnErroredPortTable 1 4 There is one Errored Port Table per bridge component or end
    station. It permits the retrieval of information about which
    interfac…
    1.3.111.2.802.1.1.18.1.4 ieee8021CnPortPriTable 1 10 Each row in this table supplies values for one port's
    Congestion Notification Priority Value (CNPV).

    Creating an entry in ieee802…
    1.3.111.2.802.1.1.18.1.5 ieee8021CnCpTable 1 14 Each row in this table supplies values for one
    Congestion Point (CP).

    This table is indexed by component, port (interface), and
    an…
    1.3.111.2.802.1.1.18.1.6 ieee8021CnCpidToInterfaceTable 1 5 This table allows the network manager to obtain the
    interface index and CP index needed to access an entry in
    the ieee8021CnCpTab…
    1.3.111.2.802.1.1.18.1.7 ieee8021CnRpPortPriTable 1 7 Each row in this table supplies values for all of the
    Reaction Points (RPs) on one Port and one priority of an end
    station or bri…
    1.3.111.2.802.1.1.18.1.8 ieee8021CnRpGroupTable 1 15 Each row in this table supplies values for one or more
    Reaction Points (RPs). This table is indexed by component,
    port (interfac…