ieee8021CnCpTable OBJECT-TYPE
SYNTAX SEQUENCE OF Ieee8021CnCpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each row in this table supplies values for one
Congestion Point (CP).
This table is indexed by component, port (interface), and
an arbitrary CP index. This arbitrary CP index is not
necessarily the Congestion Point Identifier (CPID) carried in
Congestion Notification Messages (CNMs).
Creating an entry in ieee8021CnCompntPriTable can create an
entry in this table, with the default values, on all ports in
the bridge component or end station. Because more than one
Congestion Notification Priority Value (CNPV) can flow
through a single CP, the creation of an entry in
ieee8021CnCompntPriTable does not necessarily create a new
entry in this table. An end station can have more than one
CP for the same CNPV, so creating an entry in
ieee8021CnCompntPriTable can create multiple entries in this
table.
Because each port in a bridge component or end station can have
a different relationship between CNPVs and CPs, the entries
created or deleted on each port can be different.
Deleting the last entry in ieee8021CnCompntPriTable for a
CNPV passing through the CP controlled by this entry deletes
the entry on some or all of the ports in the bridge component
or end station.
Because each port in a bridge component or end station can have
a different relationship between CNPVs and CPs, the entries
created or deleted on each port can be different.
The relationship between ieee8021CnCpIndex
values and CPs is an implementation dependent matter.
The contents of this table SHALL be maintained across a restart
of the system, except as noted in the description of
ieee8021CnCpIfIndex.
"
REFERENCE
"802.1Qau clause 12.21.4"
View at oid-info.com
Each row in this table supplies values for one
Congestion Point (CP).
This table is indexed by component, port (interface), and
an arbitrary CP index. This arbitrary CP index is not
necessarily the Congestion Point Identifier (CPID) carried in
Congestion Notification Messages (CNMs).
Creating an entry in ieee8021CnCompntPriTable can create an
entry in this table, with the default values, on all ports in
the bridge component or end station. Because more than one
Congestion Notification Priority Value (CNPV) can flow
through a single CP, the creation of an entry in
ieee8021CnCompntPriTable does not necessarily create a new
entry in this table. An end station can have more than one
CP for the same CNPV, so creating an entry in
ieee8021CnCompntPriTable can create multiple entries in this
table.
Because each port in a bridge component or end station can have
a different relationship between CNPVs and CPs, the entries
created or deleted on each port can be different.
Deleting the last entry in ieee8021CnCompntPriTable for a
CNPV passing through the CP controlled by this entry deletes
the entry on some or all of the ports in the bridge component
or end station.
Because each port in a bridge component or end station can have
a different relationship between CNPVs and CPs, the entries
created or deleted on each port can be different.
The relationship between ieee8021CnCpIndex
values and CPs is an implementation dependent matter.
The contents of this table SHALL be maintained across a restart
of the system, except as noted in the description of
ieee8021CnCpIfIndex.
Automatically extracted from IEEE Management Information Bases (MIBs)
ieee8021CnCpTable OBJECT-TYPE SYNTAX SEQUENCE OF Ieee8021CnCpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each row in this table supplies values for one Congestion Point (CP). This table is indexed by component, port (interface), and an arbitrary CP index. This arbitrary CP index is not necessarily the Congestion Point Identifier (CPID) carried in Congestion Notification Messages (CNMs). Creating an entry in ieee8021CnCompntPriTable can create an entry in this table, with the default values, on all ports in the bridge component or end station. Because more than one Congestion Notification Priority Value (CNPV) can flow through a single CP, the creation of an entry in ieee8021CnCompntPriTable does not necessarily create a new entry in this table. An end station can have more than one CP for the same CNPV, so creating an entry in ieee8021CnCompntPriTable can create multiple entries in this table. Because each port in a bridge component or end station can have a different relationship between CNPVs and CPs, the entries created or deleted on each port can be different. Deleting the last entry in ieee8021CnCompntPriTable for a CNPV passing through the CP controlled by this entry deletes the entry on some or all of the ports in the bridge component or end station. Because each port in a bridge component or end station can have a different relationship between CNPVs and CPs, the entries created or deleted on each port can be different. The relationship between ieee8021CnCpIndex values and CPs is an implementation dependent matter. The contents of this table SHALL be maintained across a restart of the system, except as noted in the description of ieee8021CnCpIfIndex. " REFERENCE "802.1Qau clause 12.17.4" ::= { ieee8021CnMIBObjects 5 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.111.2.802.1.1.18.1.5.1 | ieee8021CnCpEntry | 13 | 13 | An entry in the Congestion Point table controls a single Congestion Point on a port in a bridge component or end station. |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.111.2.802.1.1.18.1.1 | ieee8021CnGlobalTable | 1 | 5 | A table containing the global variables for each component of a bridge or for an end station. A value of 1 is used in a bridge o… |
1.3.111.2.802.1.1.18.1.2 | ieee8021CnErroredPortTable | 1 | 4 | There is one Errored Port Table per bridge component or end station. It permits the retrieval of information about which interfac… |
1.3.111.2.802.1.1.18.1.3 | ieee8021CnCompntPriTable | 1 | 11 | Each row in this table supplies default values for one Congestion Notification Priority Value for a whole bridge component or end… |
1.3.111.2.802.1.1.18.1.4 | ieee8021CnPortPriTable | 1 | 10 | Each row in this table supplies values for one port's Congestion Notification Priority Value (CNPV). Creating an entry in ieee802… |
1.3.111.2.802.1.1.18.1.6 | ieee8021CnCpidToInterfaceTable | 1 | 5 | This table allows the network manager to obtain the interface index and CP index needed to access an entry in the ieee8021CnCpTab… |
1.3.111.2.802.1.1.18.1.7 | ieee8021CnRpPortPriTable | 1 | 7 | Each row in this table supplies values for all of the Reaction Points (RPs) on one Port and one priority of an end station or bri… |
1.3.111.2.802.1.1.18.1.8 | ieee8021CnRpGroupTable | 1 | 15 | Each row in this table supplies values for one or more Reaction Points (RPs). This table is indexed by component, port (interfac… |