Reference record for OID 1.3.6.1.2.1.10.127.1.1.2.1.16



parent
1.3.6.1.2.1.10.127.1.1.2.1 (docsIfUpstreamChannelEntry)
node code
16
node name
docsIfUpChannelCloneFrom
dot oid
1.3.6.1.2.1.10.127.1.1.2.1.16
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) mgmt(2) mib-2(1) transmission(10) docsIfMib(127) docsIfMibObjects(1) docsIfBaseObjects(1) docsIfUpstreamChannelTable(2) docsIfUpstreamChannelEntry(1) docsIfUpChannelCloneFrom(16)}
  • {iso(1) identified-organization(3) dod(6) internet(1) mgmt(2) mib(1) transmission(10) docsIfMib(127) docsIfMibObjects(1) docsIfBaseObjects(1) docsIfUpstreamChannelTable(2) docsIfUpstreamChannelEntry(1) docsIfUpChannelCloneFrom(16)}
  • {iso(1) org(3) dod(6) internet(1) mgmt(2) mib-2(1) transmission(10) docsIfMib(127) docsIfMibObjects(1) docsIfBaseObjects(1) docsIfUpstreamChannelTable(2) docsIfUpstreamChannelEntry(1) docsIfUpChannelCloneFrom(16)}
  • {iso(1) org(3) dod(6) internet(1) mgmt(2) mib(1) transmission(10) docsIfMib(127) docsIfMibObjects(1) docsIfBaseObjects(1) docsIfUpstreamChannelTable(2) docsIfUpstreamChannelEntry(1) docsIfUpChannelCloneFrom(16)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) mgmt(2) mib-2(1) transmission(10) docsIfMib(127) docsIfMibObjects(1) docsIfBaseObjects(1) docsIfUpstreamChannelTable(2) docsIfUpstreamChannelEntry(1) docsIfUpChannelCloneFrom(16)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) mgmt(2) mib(1) transmission(10) docsIfMib(127) docsIfMibObjects(1) docsIfBaseObjects(1) docsIfUpstreamChannelTable(2) docsIfUpstreamChannelEntry(1) docsIfUpChannelCloneFrom(16)}
  • iri oid
  • /iso/identified-organization/dod/internet/mgmt/mib-2/transmission/docsIfMib/docsIfMibObjects/docsIfBaseObjects/docsIfUpstreamChannelTable/docsIfUpstreamChannelEntry/docsIfUpChannelCloneFrom
  • /iso/identified-organization/dod/internet/mgmt/mib/transmission/docsIfMib/docsIfMibObjects/docsIfBaseObjects/docsIfUpstreamChannelTable/docsIfUpstreamChannelEntry/docsIfUpChannelCloneFrom
  • /iso/org/dod/internet/mgmt/mib-2/transmission/docsIfMib/docsIfMibObjects/docsIfBaseObjects/docsIfUpstreamChannelTable/docsIfUpstreamChannelEntry/docsIfUpChannelCloneFrom
  • /iso/org/dod/internet/mgmt/mib/transmission/docsIfMib/docsIfMibObjects/docsIfBaseObjects/docsIfUpstreamChannelTable/docsIfUpstreamChannelEntry/docsIfUpChannelCloneFrom
  • /iso/iso-identified-organization/dod/internet/mgmt/mib-2/transmission/docsIfMib/docsIfMibObjects/docsIfBaseObjects/docsIfUpstreamChannelTable/docsIfUpstreamChannelEntry/docsIfUpChannelCloneFrom
  • /iso/iso-identified-organization/dod/internet/mgmt/mib/transmission/docsIfMib/docsIfMibObjects/docsIfBaseObjects/docsIfUpstreamChannelTable/docsIfUpstreamChannelEntry/docsIfUpChannelCloneFrom
  • iri by oid_info
    /ISO/Identified-Organization/6/1/2/1/10/127/1/1/2/1/16

    Description by circitor

    This object contains the ifIndex value of the physical
    interface row entry whose parameters are to be adjusted.

    Upon setting this object to the ifIndex value of a
    physical interface, the following interface objects values
    are copied to this entry:
    docsIfUpChannelFrequency,
    docsIfUpChannelWidth,
    docsIfUpChannelModulationProfile,
    docsIfUpChannelSlotSize,
    docsIfUpChannelRangingBackoffStart,
    docsIfUpChannelRangingBackoffEnd,
    docsIfUpChannelTxBackoffStart,
    docsIfUpChannelTxBackoffEnd,
    docsIfUpChannelScdmaActiveCodes,
    docsIfUpChannelScdmaCodesPerSlot,
    docsIfUpChannelScdmaFrameSize,
    docsIfUpChannelScdmaHoppingSeed,
    docsIfUpChannelType, and
    docsIfUpChannelPreEqEnable
    Setting this object to the value of a non-existent or
    a temporary upstream interface returns the error
    'wrongValue'.
    This object MUST contain a value of zero for physical
    interfaces entries.
    Setting this object in row entries that correspond to
    physical interfaces returns the error 'wrongValue'.

    Parsed from file DOCS-IF-MIB.mib
    Module: DOCS-IF-MIB

    Description by cisco_v1

    This object contains the ifIndex value of the physical
    interface row entry whose parameters are to be adjusted.

    Upon setting this object to the ifIndex value of a
    physical interface, the following interface objects values
    are copied to this entry:
    docsIfUpChannelFrequency,
    docsIfUpChannelWidth,
    docsIfUpChannelModulationProfile,
    docsIfUpChannelSlotSize,
    docsIfUpChannelRangingBackoffStart,
    docsIfUpChannelRangingBackoffEnd,
    docsIfUpChannelTxBackoffStart,
    docsIfUpChannelTxBackoffEnd,
    docsIfUpChannelScdmaActiveCodes,
    docsIfUpChannelScdmaCodesPerSlot,
    docsIfUpChannelScdmaFrameSize,
    docsIfUpChannelScdmaHoppingSeed,
    docsIfUpChannelType, and
    docsIfUpChannelPreEqEnable
    Setting this object to the value of a non-existent or
    a temporary upstream interface returns the error
    'wrongValue'.
    This object MUST contain a value of zero for physical
    interfaces entries.
    Setting this object in row entries that correspond to
    physical interfaces returns the error 'wrongValue'.

    Description by oid_info

    docsIfUpChannelCloneFrom OBJECT-TYPE
    SYNTAX InterfaceIndexOrZero
    MAX-ACCESS read-create
    STATUS current
    DESCRIPTION
    "Intended for use when a temporary inactive upstream table row is
    created for the purpose of manipulating SCDMA parameters for an
    active row. Refer to the descriptions of docsIfUpChannelStatus
    and docsIfUpChannelUpdate for details of this procedure.
    This object contains the ifIndex value of the active upstream
    row whose SCDMA parameters are to be adjusted.
    Although this object was created to facilitate SCDMA parameter
    adjustment, it may also be used at the vendors discretion for
    non-SCDMA parameter adjustment.
    This object must contain a value of zero for active upstream rows."

    View at oid-info.com

    Description by mibdepot

    This object contains the ifIndex value of the physical
    interface row entry whose parameters are to be adjusted.

    Upon setting this object to the ifIndex value of a
    physical interface, the following interface objects values
    are copied to this entry:
    docsIfUpChannelFrequency,
    docsIfUpChannelWidth,
    docsIfUpChannelModulationProfile,
    docsIfUpChannelSlotSize,
    docsIfUpChannelRangingBackoffStart,
    docsIfUpChannelRangingBackoffEnd,
    docsIfUpChannelTxBackoffStart,
    docsIfUpChannelTxBackoffEnd,
    docsIfUpChannelScdmaActiveCodes,
    docsIfUpChannelScdmaCodesPerSlot,
    docsIfUpChannelScdmaFrameSize,
    docsIfUpChannelScdmaHoppingSeed,
    docsIfUpChannelType, and
    docsIfUpChannelPreEqEnable
    Setting this object to the value of a non-existent or
    a temporary upstream interface returns the error
    'wrongValue'.
    This object MUST contain a value of zero for physical
    interfaces entries.
    Setting this object in row entries that correspond to
    physical interfaces returns the error 'wrongValue'.

    Parsed from file DOCS-IF-MIB.txt
    Company: None
    Module: DOCS-IF-MIB

    Description by cisco

    This object contains the ifIndex value of the physical
    interface row entry whose parameters are to be adjusted.

    Upon setting this object to the ifIndex value of a
    physical interface, the following interface objects values
    are copied to this entry:
    docsIfUpChannelFrequency,
    docsIfUpChannelWidth,
    docsIfUpChannelModulationProfile,
    docsIfUpChannelSlotSize,
    docsIfUpChannelRangingBackoffStart,
    docsIfUpChannelRangingBackoffEnd,
    docsIfUpChannelTxBackoffStart,
    docsIfUpChannelTxBackoffEnd,
    docsIfUpChannelScdmaActiveCodes,
    docsIfUpChannelScdmaCodesPerSlot,
    docsIfUpChannelScdmaFrameSize,
    docsIfUpChannelScdmaHoppingSeed,
    docsIfUpChannelType, and
    docsIfUpChannelPreEqEnable
    Setting this object to the value of a non-existent or
    a temporary upstream interface returns the error
    'wrongValue'.
    This object MUST contain a value of zero for physical
    interfaces entries.
    Setting this object in row entries that correspond to
    physical interfaces returns the error 'wrongValue'.

    Information by circitor

    docsIfUpChannelCloneFrom OBJECT-TYPE SYNTAX InterfaceIndexOrZero ACCESS read-write STATUS mandatory DESCRIPTION "This object contains the ifIndex value of the physical interface row entry whose parameters are to be adjusted. Upon setting this object to the ifIndex value of a physical interface, the following interface objects values are copied to this entry: docsIfUpChannelFrequency, docsIfUpChannelWidth, docsIfUpChannelModulationProfile, docsIfUpChannelSlotSize, docsIfUpChannelRangingBackoffStart, docsIfUpChannelRangingBackoffEnd, docsIfUpChannelTxBackoffStart, docsIfUpChannelTxBackoffEnd, docsIfUpChannelScdmaActiveCodes, docsIfUpChannelScdmaCodesPerSlot, docsIfUpChannelScdmaFrameSize, docsIfUpChannelScdmaHoppingSeed, docsIfUpChannelType, and docsIfUpChannelPreEqEnable Setting this object to the value of a non-existent or a temporary upstream interface returns the error 'wrongValue'. This object MUST contain a value of zero for physical interfaces entries. Setting this object in row entries that correspond to physical interfaces returns the error 'wrongValue'." ::= { docsIfUpstreamChannelEntry 16 }

    Information by cisco_v1

    docsIfUpChannelCloneFrom OBJECT-TYPE SYNTAX InterfaceIndexOrZero ACCESS read-write STATUS mandatory DESCRIPTION "This object contains the ifIndex value of the physical interface row entry whose parameters are to be adjusted. Upon setting this object to the ifIndex value of a physical interface, the following interface objects values are copied to this entry: docsIfUpChannelFrequency, docsIfUpChannelWidth, docsIfUpChannelModulationProfile, docsIfUpChannelSlotSize, docsIfUpChannelRangingBackoffStart, docsIfUpChannelRangingBackoffEnd, docsIfUpChannelTxBackoffStart, docsIfUpChannelTxBackoffEnd, docsIfUpChannelScdmaActiveCodes, docsIfUpChannelScdmaCodesPerSlot, docsIfUpChannelScdmaFrameSize, docsIfUpChannelScdmaHoppingSeed, docsIfUpChannelType, and docsIfUpChannelPreEqEnable Setting this object to the value of a non-existent or a temporary upstream interface returns the error 'wrongValue'. This object MUST contain a value of zero for physical interfaces entries. Setting this object in row entries that correspond to physical interfaces returns the error 'wrongValue'." ::= { docsIfUpstreamChannelEntry 16 }

    Information by oid_info

    Automatically extracted from Cisco "SNMP v2 MIBs".

    Information by mibdepot

    docsIfUpChannelCloneFrom OBJECT-TYPE SYNTAX InterfaceIndexOrZero MAX-ACCESS read-create STATUS current DESCRIPTION "This object contains the ifIndex value of the physical interface row entry whose parameters are to be adjusted. Upon setting this object to the ifIndex value of a physical interface, the following interface objects values are copied to this entry: docsIfUpChannelFrequency, docsIfUpChannelWidth, docsIfUpChannelModulationProfile, docsIfUpChannelSlotSize, docsIfUpChannelRangingBackoffStart, docsIfUpChannelRangingBackoffEnd, docsIfUpChannelTxBackoffStart, docsIfUpChannelTxBackoffEnd, docsIfUpChannelScdmaActiveCodes, docsIfUpChannelScdmaCodesPerSlot, docsIfUpChannelScdmaFrameSize, docsIfUpChannelScdmaHoppingSeed, docsIfUpChannelType, and docsIfUpChannelPreEqEnable Setting this object to the value of a non-existent or a temporary upstream interface returns the error 'wrongValue'. This object MUST contain a value of zero for physical interfaces entries. Setting this object in row entries that correspond to physical interfaces returns the error 'wrongValue'." ::= { docsIfUpstreamChannelEntry 16 }

    Information by cisco

    docsIfUpChannelCloneFrom OBJECT-TYPE SYNTAX InterfaceIndexOrZero MAX-ACCESS read-create STATUS current DESCRIPTION "This object contains the ifIndex value of the physical interface row entry whose parameters are to be adjusted. Upon setting this object to the ifIndex value of a physical interface, the following interface objects values are copied to this entry: docsIfUpChannelFrequency, docsIfUpChannelWidth, docsIfUpChannelModulationProfile, docsIfUpChannelSlotSize, docsIfUpChannelRangingBackoffStart, docsIfUpChannelRangingBackoffEnd, docsIfUpChannelTxBackoffStart, docsIfUpChannelTxBackoffEnd, docsIfUpChannelScdmaActiveCodes, docsIfUpChannelScdmaCodesPerSlot, docsIfUpChannelScdmaFrameSize, docsIfUpChannelScdmaHoppingSeed, docsIfUpChannelType, and docsIfUpChannelPreEqEnable Setting this object to the value of a non-existent or a temporary upstream interface returns the error 'wrongValue'. This object MUST contain a value of zero for physical interfaces entries. Setting this object in row entries that correspond to physical interfaces returns the error 'wrongValue'." ::= { docsIfUpstreamChannelEntry 16 }

    First Registration Authority (recovered by parent 1.3.6)

    Defense Communication Agency

    Current Registration Authority (recovered by parent 1.3.6.1.2)

    Internet Assigned Numbers Authority

    Brothers (18)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.2.1.10.127.1.1.2.1.1 docsIfUpChannelId 0 0 The CMTS identification of the upstream channel.
    1.3.6.1.2.1.10.127.1.1.2.1.2 docsIfUpChannelFrequency 0 0 The center of the frequency band associated with this
    upstream channel. This object returns 0 if the frequency
    is undefined or un…
    1.3.6.1.2.1.10.127.1.1.2.1.3 docsIfUpChannelWidth 0 0 The bandwidth of this upstream channel. This object
    returns 0 if the channel width is undefined or unknown.
    Minimum permitted cha…
    1.3.6.1.2.1.10.127.1.1.2.1.4 docsIfUpChannelModulationProfile 0 0 An entry identical to the docsIfModIndex in the
    docsIfCmtsModulationTable that describes this channel.
    This channel is further in…
    1.3.6.1.2.1.10.127.1.1.2.1.5 docsIfUpChannelSlotSize 0 0 The number of 6.25 microsecond ticks in each upstream mini-
    slot. Returns zero if the value is undefined or unknown.
    See the asso…
    1.3.6.1.2.1.10.127.1.1.2.1.6 docsIfUpChannelTxTimingOffset 0 0 A measure of the current round trip time at the CM, or the
    maximum round trip time seen by the CMTS. Used for timing
    of CM upstr…
    1.3.6.1.2.1.10.127.1.1.2.1.7 docsIfUpChannelRangingBackoffStart 0 0 The initial random backoff window to use when retrying
    Ranging Requests. Expressed as a power of 2. A value of 16
    at the CMTS ind…
    1.3.6.1.2.1.10.127.1.1.2.1.8 docsIfUpChannelRangingBackoffEnd 0 0 The final random backoff window to use when retrying
    Ranging Requests. Expressed as a power of 2. A value of 16
    at the CMTS indic…
    1.3.6.1.2.1.10.127.1.1.2.1.9 docsIfUpChannelTxBackoffStart 0 0 The initial random backoff window to use when retrying
    transmissions. Expressed as a power of 2. A value of 16
    at the CMTS indica…
    1.3.6.1.2.1.10.127.1.1.2.1.10 docsIfUpChannelTxBackoffEnd 0 0 The final random backoff window to use when retrying
    transmissions. Expressed as a power of 2. A value of 16
    at the CMTS indicate…
    1.3.6.1.2.1.10.127.1.1.2.1.11 docsIfUpChannelScdmaActiveCodes 0 0 Applicable for SCDMA channel types only.
    Number of active codes. Returns zero for
    Non-SCDMA channel types. Note that legal
    value…
    1.3.6.1.2.1.10.127.1.1.2.1.12 docsIfUpChannelScdmaCodesPerSlot 0 0 Applicable for SCDMA channel types only.
    The number of SCDMA codes per mini-slot.
    Returns zero if the value is undefined or unkno…
    1.3.6.1.2.1.10.127.1.1.2.1.13 docsIfUpChannelScdmaFrameSize 0 0 Applicable for SCDMA channel types only.
    SCDMA Frame size in units of spreading intervals.
    This value returns zero for non-SCDMA …
    1.3.6.1.2.1.10.127.1.1.2.1.14 docsIfUpChannelScdmaHoppingSeed 0 0 Applicable for SCDMA channel types only.
    15-bit seed used for code hopping sequence initialization.
    Returns zero for non-SCDMA ch…
    1.3.6.1.2.1.10.127.1.1.2.1.15 docsIfUpChannelType 0 0 Reflects the Upstream channel type.
    This object returns the value of docsIfCmtsModChannelType
    for the modulation profile selected…
    1.3.6.1.2.1.10.127.1.1.2.1.17 docsIfUpChannelUpdate 0 0 Used to perform the copy of adjusted parameters from the
    temporary interface entry to the physical interface
    indicated by the doc…
    1.3.6.1.2.1.10.127.1.1.2.1.18 docsIfUpChannelStatus 0 0 docsIfUpChannelStatus OBJECT-TYPE
    SYNTAX RowStatus
    MAX-ACCESS read-create
    STATUS current
    DESCRIPTION
    "This object is generally …
    1.3.6.1.2.1.10.127.1.1.2.1.19 docsIfUpChannelPreEqEnable 0 0 At the CMTS, this object is used to enable or disable
    pre-equalization on the upstream channel represented by