Number of times counter T1 expired in the CM.
Discontinuities in the value of this counter can occur
at reinitialization of the managed system, and at other
times as indicated by the value of
ifCounterDiscontinuityTime for the associated ifIndex.
Parsed from file DOCS-IF-MIB.mib
Module: DOCS-IF-MIB
Number of times counter T1 expired in the CM.
Discontinuities in the value of this counter can occur
at reinitialization of the managed system, and at other
times as indicated by the value of
ifCounterDiscontinuityTime for the associated ifIndex.
docsIfCmStatusT1Timeouts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of times counter T1 expired in the CM."
REFERENCE
"DOCSIS Radio Frequency Interface specification,
Figure 7-3."
View at oid-info.com
Number of times counter T1 expired in the CM.
Parsed from file DOCS-IF-MIB.txt
Company: None
Module: DOCS-IF-MIB
Number of times counter T1 expired in the CM.
Discontinuities in the value of this counter can occur
at reinitialization of the managed system, and at other
times as indicated by the value of
ifCounterDiscontinuityTime for the associated ifIndex.
docsIfCmStatusT1Timeouts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of times counter T1 expired in the CM. Discontinuities in the value of this counter can occur at reinitialization of the managed system, and at other times as indicated by the value of ifCounterDiscontinuityTime for the associated ifIndex." REFERENCE "Data-Over-Cable Service Interface Specifications: Radio Frequency Interface Specification SP-RFIv2.0-I10-051209, Figure 9-2." ::= { docsIfCmStatusEntry 10 }
docsIfCmStatusT1Timeouts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of times counter T1 expired in the CM. Discontinuities in the value of this counter can occur at reinitialization of the managed system, and at other times as indicated by the value of ifCounterDiscontinuityTime for the associated ifIndex." REFERENCE "Data-Over-Cable Service Interface Specifications: Radio Frequency Interface Specification SP-RFIv2.0-I10-051209, Figure 9-2." ::= { docsIfCmStatusEntry 10 }
Automatically extracted from RFC2670
docsIfCmStatusT1Timeouts OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of times counter T1 expired in the CM." REFERENCE "DOCSIS Radio Frequency Interface specification, Figure 7-3." ::= { docsIfCmStatusEntry 10 }
docsIfCmStatusT1Timeouts OBJECT-TYPE SYNTAX Counter32 UNITS "timeouts" MAX-ACCESS read-only STATUS current DESCRIPTION "Number of times counter T1 expired in the CM. Discontinuities in the value of this counter can occur at reinitialization of the managed system, and at other times as indicated by the value of ifCounterDiscontinuityTime for the associated ifIndex." REFERENCE "Data-Over-Cable Service Interface Specifications: Radio Frequency Interface Specification SP-RFIv2.0-I10-051209, Figure 9-2." ::= { docsIfCmStatusEntry 10 }
Internet Assigned Numbers Authority
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.2.1.10.127.1.2.2.1.1 | docsIfCmStatusValue | 0 | 0 | Current Cable Modem connectivity state, as specified in the RF Interface Specification. |
1.3.6.1.2.1.10.127.1.2.2.1.2 | docsIfCmStatusCode | 0 | 0 | Status code for this Cable Modem as defined in the RF Interface Specification. The status code consists of a single character ind… |
1.3.6.1.2.1.10.127.1.2.2.1.3 | docsIfCmStatusTxPower | 0 | 0 | The operational transmit power for the attached upstream channel. |
1.3.6.1.2.1.10.127.1.2.2.1.4 | docsIfCmStatusResets | 0 | 0 | Number of times the CM reset or initialized this interface. |
1.3.6.1.2.1.10.127.1.2.2.1.5 | docsIfCmStatusLostSyncs | 0 | 0 | Number of times the CM lost synchronization with the downstream channel. |
1.3.6.1.2.1.10.127.1.2.2.1.6 | docsIfCmStatusInvalidMaps | 0 | 0 | Number of times the CM received invalid MAP messages. |
1.3.6.1.2.1.10.127.1.2.2.1.7 | docsIfCmStatusInvalidUcds | 0 | 0 | Number of times the CM received invalid UCD messages. |
1.3.6.1.2.1.10.127.1.2.2.1.8 | docsIfCmStatusInvalidRangingResponses, docsIfCmStatusInvalidRangingResp | 0 | 0 | Number of times the CM received invalid ranging response messages. |
1.3.6.1.2.1.10.127.1.2.2.1.9 | docsIfCmStatusInvalidRegistrationResponses, docsIfCmStatusInvalidRegistrationResp | 0 | 0 | Number of times the CM received invalid registration response messages. |
1.3.6.1.2.1.10.127.1.2.2.1.11 | docsIfCmStatusT2Timeouts | 0 | 0 | Number of times counter T2 expired in the CM. |
1.3.6.1.2.1.10.127.1.2.2.1.12 | docsIfCmStatusT3Timeouts | 0 | 0 | Number of times counter T3 expired in the CM. |
1.3.6.1.2.1.10.127.1.2.2.1.13 | docsIfCmStatusT4Timeouts | 0 | 0 | Number of times counter T4 expired in the CM. |
1.3.6.1.2.1.10.127.1.2.2.1.14 | docsIfCmStatusRangingAborteds | 0 | 0 | Number of times the ranging process was aborted by the CMTS. |
1.3.6.1.2.1.10.127.1.2.2.1.15 | docsIfCmStatusDocsisOperMode | 0 | 0 | Indication of whether the device has registered using 1.0 Class of Service or 1.1 Quality of Service. An unregistered CM SHOULD i… |
1.3.6.1.2.1.10.127.1.2.2.1.16 | docsIfCmStatusModulationType | 0 | 0 | Indicates modulation type status currently used by the CM. Since this object specifically identifies PHY mode, the shared upstre… |
1.3.6.1.2.1.10.127.1.2.2.1.17 | docsIfCmStatusEqualizationData | 0 | 0 | Pre-equalization data for this CM after convolution with data indicated in the RNG-RSP. This data is valid when docsIfUpChannelP… |
1.3.6.1.2.1.10.127.1.2.2.1.18 | docsIfCmStatusUCCs | 0 | 0 | The number of successful Upstream Channel Change transactions. Discontinuities in the value of this counter can occur at reinitial… |
1.3.6.1.2.1.10.127.1.2.2.1.19 | docsIfCmStatusUCCFails | 0 | 0 | The number of failed Upstream Channel Change transactions. Discontinuities in the value of this counter can occur at reinitializat… |