optIfOTUkDAPIExpected OBJECT-TYPE
SYNTAX OptIfExDAPI
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The DAPI expected by the receiver.
This object is only applicable to the sink function, i.e.,
only when optIfOTUkDirectionality has the value sink(1)
or bidirectional(3). It must not be instantiated in rows
where optIfOTUkDirectionality has the value source(2).
This object has no effect when optIfOTUkTIMDetMode has
the value off(1)."
View at oid-info.com
The DAPI expected by the receiver.
This object is only applicable to the sink function, i.e.,
only when optIfOTUkDirectionality has the value sink(1)
or bidirectional(3). It must not be instantiated in rows
where optIfOTUkDirectionality has the value source(2).
This object has no effect when optIfOTUkTIMDetMode has
the value off(1).
Parsed from file rfc3591-Optical-Interface-Type.mib.txt
Company: None
Module: OPT-IF-MIB
The DAPI expected by the receiver.
This object is only applicable to the sink function, i.e.,
only when optIfOTUkDirectionality has the value sink(1)
or bidirectional(3). It must not be instantiated in rows
where optIfOTUkDirectionality has the value source(2).
This object has no effect when optIfOTUkTIMDetMode has
the value off(1).
Parsed from file OPT-IF-MIB.mib
Module: OPT-IF-MIB
Automatically extracted from RFC3591
optIfOTUkDAPIExpected OBJECT-TYPE SYNTAX OptIfExDAPI MAX-ACCESS read-write STATUS current DESCRIPTION "The DAPI expected by the receiver. This object is only applicable to the sink function, i.e., only when optIfOTUkDirectionality has the value sink(1) or bidirectional(3). It must not be instantiated in rows where optIfOTUkDirectionality has the value source(2). This object has no effect when optIfOTUkTIMDetMode has the value off(1)." ::= { optIfOTUkConfigEntry 4 }
optIfOTUkDAPIExpected OBJECT-TYPE SYNTAX OptIfExDAPI MAX-ACCESS read-write STATUS current DESCRIPTION "The DAPI expected by the receiver. This object is only applicable to the sink function, i.e., only when optIfOTUkDirectionality has the value sink(1) or bidirectional(3). It must not be instantiated in rows where optIfOTUkDirectionality has the value source(2). This object has no effect when optIfOTUkTIMDetMode has the value off(1)." ::= { optIfOTUkConfigEntry 4 }
Internet Assigned Numbers Authority
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.2.1.10.133.1.7.1.1.1 | optIfOTUkDirectionality | 0 | 0 | Indicates the directionality of the entity. |
1.3.6.1.2.1.10.133.1.7.1.1.2 | optIfOTUkBitRateK | 0 | 0 | Indicates the bit rate of the entity. |
1.3.6.1.2.1.10.133.1.7.1.1.3 | optIfOTUkTraceIdentifierTransmitted | 0 | 0 | The trace identifier transmitted. This object is applicable when optIfOTUkDirectionality has the value source(2) or bidirectional… |
1.3.6.1.2.1.10.133.1.7.1.1.5 | optIfOTUkSAPIExpected | 0 | 0 | The SAPI expected by the receiver. This object is only applicable to the sink function, i.e., only when optIfOTUkDirectionality h… |
1.3.6.1.2.1.10.133.1.7.1.1.6 | optIfOTUkTraceIdentifierAccepted | 0 | 0 | The actual trace identifier accepted. This object is only applicable to the sink function, i.e., only when optIfOTUkDirectionalit… |
1.3.6.1.2.1.10.133.1.7.1.1.7 | optIfOTUkTIMDetMode | 0 | 0 | Indicates the mode of the Trace Identifier Mismatch (TIM) Detection function. This object is only applicable to the sink function… |
1.3.6.1.2.1.10.133.1.7.1.1.8 | optIfOTUkTIMActEnabled | 0 | 0 | Indicates whether the Trace Identifier Mismatch (TIM) Consequent Action function is enabled. This object is only applicable to th… |
1.3.6.1.2.1.10.133.1.7.1.1.9 | optIfOTUkDEGThr | 0 | 0 | Indicates the threshold level for declaring a performance monitoring (PM) Second to be bad. A PM Second is declared bad if the p… |
1.3.6.1.2.1.10.133.1.7.1.1.10 | optIfOTUkDEGM | 0 | 0 | Indicates the threshold level for declaring a Degraded Signal defect (dDEG). A dDEG shall be declared if optIfOTUkDEGM consecuti… |
1.3.6.1.2.1.10.133.1.7.1.1.11 | optIfOTUkSinkAdaptActive | 0 | 0 | Indicates whether the sink adaptation function is activated or not. This object is only applicable to the sink function, i.e., onl… |
1.3.6.1.2.1.10.133.1.7.1.1.12 | optIfOTUkSourceAdaptActive | 0 | 0 | Indicates whether the source adaptation function is activated or not. This object is only applicable to the source function, i.e.… |
1.3.6.1.2.1.10.133.1.7.1.1.13 | optIfOTUkSinkFECEnabled | 0 | 0 | If Forward Error Correction (FEC) is supported, this object indicates whether FEC at the OTUk sink adaptation function is enabled… |
1.3.6.1.2.1.10.133.1.7.1.1.14 | optIfOTUkCurrentStatus | 0 | 0 | Indicates the defect condition of the entity, if any. This object is only applicable to the sink function, i.e., only when optIfO… |