optIfODUkNimTraceIdentifierAccepted OBJECT-TYPE
SYNTAX OptIfAcTI
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The actual trace identifier accepted. The value of
this object is unspecified if optIfODUkNimCurrentStatus
has any of the bit positions oci(0), lck(1), or ssf(5)
set or if optIfODUkNimRowStatus has any value other
than active(1)."
View at oid-info.com
The actual trace identifier accepted. The value of
this object is unspecified if optIfODUkNimCurrentStatus
has any of the bit positions oci(0), lck(1), or ssf(5)
set or if optIfODUkNimRowStatus has any value other
than active(1).
Parsed from file rfc3591-Optical-Interface-Type.mib.txt
Company: None
Module: OPT-IF-MIB
The actual trace identifier accepted. The value of
this object is unspecified if optIfODUkNimCurrentStatus
has any of the bit positions oci(0), lck(1), or ssf(5)
set or if optIfODUkNimRowStatus has any value other
than active(1).
Parsed from file OPT-IF-MIB.mib
Module: OPT-IF-MIB
Automatically extracted from RFC3591
optIfODUkNimTraceIdentifierAccepted OBJECT-TYPE SYNTAX OptIfAcTI MAX-ACCESS read-only STATUS current DESCRIPTION "The actual trace identifier accepted. The value of this object is unspecified if optIfODUkNimCurrentStatus has any of the bit positions oci(0), lck(1), or ssf(5) set or if optIfODUkNimRowStatus has any value other than active(1)." ::= { optIfODUkNimConfigEntry 4 }
optIfODUkNimTraceIdentifierAccepted OBJECT-TYPE SYNTAX OptIfAcTI MAX-ACCESS read-only STATUS current DESCRIPTION "The actual trace identifier accepted. The value of this object is unspecified if optIfODUkNimCurrentStatus has any of the bit positions oci(0), lck(1), or ssf(5) set or if optIfODUkNimRowStatus has any value other than active(1)." ::= { optIfODUkNimConfigEntry 4 }
Internet Assigned Numbers Authority
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.2.1.10.133.1.8.4.1.1 | optIfODUkNimDirectionality | 0 | 0 | Specifies the monitor point for the ODUk Path non-intrusive monitoring function. The value source(2) is not allowed if the corre… |
1.3.6.1.2.1.10.133.1.8.4.1.2 | optIfODUkNimDAPIExpected | 0 | 0 | The DAPI expected by the receiver. This object has no effect if optIfODUkNimTIMDetMode has the value off(1) or sapi(3). |
1.3.6.1.2.1.10.133.1.8.4.1.3 | optIfODUkNimSAPIExpected | 0 | 0 | The SAPI expected by the receiver. This object has no effect if optIfODUkNimTIMDetMode has the value off(1) or dapi(2). |
1.3.6.1.2.1.10.133.1.8.4.1.5 | optIfODUkNimTIMDetMode | 0 | 0 | Indicates the mode of the Trace Identifier Mismatch (TIM) Detection function. |
1.3.6.1.2.1.10.133.1.8.4.1.6 | optIfODUkNimTIMActEnabled | 0 | 0 | Indicates whether the Trace Identifier Mismatch (TIM) Consequent Action function is enabled. |
1.3.6.1.2.1.10.133.1.8.4.1.7 | optIfODUkNimDEGThr | 0 | 0 | Indicates the threshold level for declaring a performance monitoring (PM) Second to be bad. A PM Second is declared bad if the p… |
1.3.6.1.2.1.10.133.1.8.4.1.8 | optIfODUkNimDEGM | 0 | 0 | Indicates the threshold level for declaring a Degraded Signal defect (dDEG). A dDEG shall be declared if optIfODUkNimDEGM consec… |
1.3.6.1.2.1.10.133.1.8.4.1.9 | optIfODUkNimCurrentStatus | 0 | 0 | Indicates the defect condition of the entity, if any. The value of this object is unspecified if optIfODUkNimRowStatus has any v… |
1.3.6.1.2.1.10.133.1.8.4.1.10 | optIfODUkNimRowStatus | 0 | 0 | This columnar object is used for creating and deleting a conceptual row of the optIfODUkNim config table. It is used to model the… |