Reference record for OID 1.3.6.1.2.1.10.133.1.9.1.1.13



parent
1.3.6.1.2.1.10.133.1.9.1.1 (optIfODUkTConfigEntry)
node code
13
node name
optIfODUkTSourceLockSignalAdminState
dot oid
1.3.6.1.2.1.10.133.1.9.1.1.13
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) mgmt(2) mib-2(1) transmission(10) optIfMibModule(133) optIfObjects(1) optIfODUkT(9) optIfODUkTConfigTable(1) optIfODUkTConfigEntry(1) optIfODUkTSourceLockSignalAdminState(13)}
  • {iso(1) identified-organization(3) dod(6) internet(1) mgmt(2) mib(1) transmission(10) optIfMibModule(133) optIfObjects(1) optIfODUkT(9) optIfODUkTConfigTable(1) optIfODUkTConfigEntry(1) optIfODUkTSourceLockSignalAdminState(13)}
  • {iso(1) org(3) dod(6) internet(1) mgmt(2) mib-2(1) transmission(10) optIfMibModule(133) optIfObjects(1) optIfODUkT(9) optIfODUkTConfigTable(1) optIfODUkTConfigEntry(1) optIfODUkTSourceLockSignalAdminState(13)}
  • {iso(1) org(3) dod(6) internet(1) mgmt(2) mib(1) transmission(10) optIfMibModule(133) optIfObjects(1) optIfODUkT(9) optIfODUkTConfigTable(1) optIfODUkTConfigEntry(1) optIfODUkTSourceLockSignalAdminState(13)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) mgmt(2) mib-2(1) transmission(10) optIfMibModule(133) optIfObjects(1) optIfODUkT(9) optIfODUkTConfigTable(1) optIfODUkTConfigEntry(1) optIfODUkTSourceLockSignalAdminState(13)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) mgmt(2) mib(1) transmission(10) optIfMibModule(133) optIfObjects(1) optIfODUkT(9) optIfODUkTConfigTable(1) optIfODUkTConfigEntry(1) optIfODUkTSourceLockSignalAdminState(13)}
  • iri oid
  • /iso/identified-organization/dod/internet/mgmt/mib-2/transmission/optIfMibModule/optIfObjects/optIfODUkT/optIfODUkTConfigTable/optIfODUkTConfigEntry/optIfODUkTSourceLockSignalAdminState
  • /iso/identified-organization/dod/internet/mgmt/mib/transmission/optIfMibModule/optIfObjects/optIfODUkT/optIfODUkTConfigTable/optIfODUkTConfigEntry/optIfODUkTSourceLockSignalAdminState
  • /iso/org/dod/internet/mgmt/mib-2/transmission/optIfMibModule/optIfObjects/optIfODUkT/optIfODUkTConfigTable/optIfODUkTConfigEntry/optIfODUkTSourceLockSignalAdminState
  • /iso/org/dod/internet/mgmt/mib/transmission/optIfMibModule/optIfObjects/optIfODUkT/optIfODUkTConfigTable/optIfODUkTConfigEntry/optIfODUkTSourceLockSignalAdminState
  • /iso/iso-identified-organization/dod/internet/mgmt/mib-2/transmission/optIfMibModule/optIfObjects/optIfODUkT/optIfODUkTConfigTable/optIfODUkTConfigEntry/optIfODUkTSourceLockSignalAdminState
  • /iso/iso-identified-organization/dod/internet/mgmt/mib/transmission/optIfMibModule/optIfObjects/optIfODUkT/optIfODUkTConfigTable/optIfODUkTConfigEntry/optIfODUkTSourceLockSignalAdminState
  • iri by oid_info
    /ISO/Identified-Organization/6/1/2/1/10/133/1/9/1/1/13

    Description by oid_info

    optIfODUkTSourceLockSignalAdminState OBJECT-TYPE
    SYNTAX INTEGER {
    locked(1),
    normal(2)
    }
    MAX-ACCESS read-create
    STATUS current
    DESCRIPTION
    "Provides the capability to provision the LOCK signal, which
    is one of the ODUk maintenance signals, at the source.
    When a Tandem Connection endpoint is set to admin state
    locked, it inserts the ODUk-LCK signal in the source
    direction.
    This object is applicable only when either one of the
    following three cases holds:
    (i) optIfODUkDirectionality has the value bidirectional(3), or
    (ii) optIfODUkDirectionality has the value sink(1) and
    optIfODUkTCodirectional has the value false(2), or
    (iii) optIfODUkDirectionality has the value source(3) and
    optIfODUkTCodirectional has the value true(1).
    It must not be instantiated in rows for all other cases."

    View at oid-info.com

    Description by mibdepot

    Provides the capability to provision the LOCK signal, which
    is one of the ODUk maintenance signals, at the source.
    When a Tandem Connection endpoint is set to admin state
    locked, it inserts the ODUk-LCK signal in the source
    direction.

    This object is applicable only when either one of the
    following three cases holds:
    (i) optIfODUkDirectionality has the value bidirectional(3), or
    (ii) optIfODUkDirectionality has the value sink(1) and
    optIfODUkTCodirectional has the value false(2), or
    (iii) optIfODUkDirectionality has the value source(3) and
    optIfODUkTCodirectional has the value true(1).
    It must not be instantiated in rows for all other cases.

    Parsed from file rfc3591-Optical-Interface-Type.mib.txt
    Company: None
    Module: OPT-IF-MIB

    Description by circitor

    Provides the capability to provision the LOCK signal, which
    is one of the ODUk maintenance signals, at the source.
    When a Tandem Connection endpoint is set to admin state
    locked, it inserts the ODUk-LCK signal in the source
    direction.



    This object is applicable only when either one of the
    following three cases holds:
    (i) optIfODUkDirectionality has the value bidirectional(3), or
    (ii) optIfODUkDirectionality has the value sink(1) and
    optIfODUkTCodirectional has the value false(2), or
    (iii) optIfODUkDirectionality has the value source(3) and
    optIfODUkTCodirectional has the value true(1).
    It must not be instantiated in rows for all other cases.

    Parsed from file OPT-IF-MIB.mib
    Module: OPT-IF-MIB

    Information by oid_info

    Automatically extracted from RFC3591

    Information by mibdepot

    optIfODUkTSourceLockSignalAdminState OBJECT-TYPE SYNTAX INTEGER { locked(1), normal(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "Provides the capability to provision the LOCK signal, which is one of the ODUk maintenance signals, at the source. When a Tandem Connection endpoint is set to admin state locked, it inserts the ODUk-LCK signal in the source direction. This object is applicable only when either one of the following three cases holds: (i) optIfODUkDirectionality has the value bidirectional(3), or (ii) optIfODUkDirectionality has the value sink(1) and optIfODUkTCodirectional has the value false(2), or (iii) optIfODUkDirectionality has the value source(3) and optIfODUkTCodirectional has the value true(1). It must not be instantiated in rows for all other cases." ::= { optIfODUkTConfigEntry 13 }

    Information by circitor

    optIfODUkTSourceLockSignalAdminState OBJECT-TYPE SYNTAX INTEGER { locked(1), normal(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "Provides the capability to provision the LOCK signal, which is one of the ODUk maintenance signals, at the source. When a Tandem Connection endpoint is set to admin state locked, it inserts the ODUk-LCK signal in the source direction. This object is applicable only when either one of the following three cases holds: (i) optIfODUkDirectionality has the value bidirectional(3), or (ii) optIfODUkDirectionality has the value sink(1) and optIfODUkTCodirectional has the value false(2), or (iii) optIfODUkDirectionality has the value source(3) and optIfODUkTCodirectional has the value true(1). It must not be instantiated in rows for all other cases." ::= { optIfODUkTConfigEntry 13 }

    First Registration Authority (recovered by parent 1.3.6)

    Defense Communication Agency

    Current Registration Authority (recovered by parent 1.3.6.1.2)

    Internet Assigned Numbers Authority

    Brothers (14)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.2.1.10.133.1.9.1.1.1 optIfODUkTTcmField 0 0 Indicates the tandem connection monitoring
    field of the ODUk OH. Valid values are
    integers from 1 to 6.
    1.3.6.1.2.1.10.133.1.9.1.1.2 optIfODUkTCodirectional 0 0 Indicates the directionality of the ODUkT termination point with
    respect to the associated ODUk CTP. The value true(1) means
    tha…
    1.3.6.1.2.1.10.133.1.9.1.1.3 optIfODUkTTraceIdentifierTransmitted 0 0 The trace identifier transmitted.
    This object is applicable only to the following three cases.
    (i) optIfODUkDirectionality has th…
    1.3.6.1.2.1.10.133.1.9.1.1.4 optIfODUkTDAPIExpected 0 0 The DAPI expected by the receiver.
    This object is applicable only to the following three cases.
    (i) optIfODUkDirectionality has t…
    1.3.6.1.2.1.10.133.1.9.1.1.5 optIfODUkTSAPIExpected 0 0 The SAPI expected by the receiver.
    This object is applicable only to the following three cases.
    (i) optIfODUkDirectionality has t…
    1.3.6.1.2.1.10.133.1.9.1.1.6 optIfODUkTTraceIdentifierAccepted 0 0 The actual trace identifier accepted.
    This object is applicable only to the following three cases.
    (i) optIfODUkDirectionality ha…
    1.3.6.1.2.1.10.133.1.9.1.1.7 optIfODUkTTIMDetMode 0 0 Indicates the mode of the Trace Identifier Mismatch (TIM)
    Detection function.
    This object is applicable only to the following thr…
    1.3.6.1.2.1.10.133.1.9.1.1.8 optIfODUkTTIMActEnabled 0 0 Indicates whether the Trace Identifier Mismatch (TIM)
    Consequent Action function is enabled.
    This object is applicable only to th…
    1.3.6.1.2.1.10.133.1.9.1.1.9 optIfODUkTDEGThr 0 0 Indicates the threshold level for declaring a performance
    monitoring (PM) Second to be bad. A PM Second is declared bad if
    the p…
    1.3.6.1.2.1.10.133.1.9.1.1.10 optIfODUkTDEGM 0 0 Indicates the threshold level for declaring a Degraded Signal
    defect (dDEG). A dDEG shall be declared if optIfODUkTDEGM
    consecut…
    1.3.6.1.2.1.10.133.1.9.1.1.11 optIfODUkTSinkMode 0 0 This variable specifies the TCM mode at the entity.
    The value operational(1) means that TCM Overhead (TCMOH)
    processes (see ITU-T…
    1.3.6.1.2.1.10.133.1.9.1.1.12 optIfODUkTSinkLockSignalAdminState 0 0 Provides the capability to provision the LOCK signal, which
    is one of the ODUk maintenance signals, at the ODUKT sink. When
    a Ta…
    1.3.6.1.2.1.10.133.1.9.1.1.14 optIfODUkTCurrentStatus 0 0 Indicates the defect condition of the entity, if any.
    This object is applicable only when either one of the
    following three cases…
    1.3.6.1.2.1.10.133.1.9.1.1.15 optIfODUkTRowStatus 0 0 This columnar object is used for creating and deleting a
    conceptual row of the optIfODUkT config table.
    It is used to model the a…