optIfODUkTDAPIExpected OBJECT-TYPE
SYNTAX OptIfExDAPI
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The DAPI expected by the receiver.
This object is applicable only to the following three cases.
(i) optIfODUkDirectionality has the value bidirectional(3), or
(ii) optIfODUkDirectionality has the value sink(1) and
optIfODUkTCodirectional has the value true(1), or
(iii) optIfODUkDirectionality has the value source(3) and
optIfODUkTCodirectional has the value false(2).
It must not be instantiated in rows for all other cases.
This object has no effect when optIfODUkTTIMDetMode has
the value off(1)."
View at oid-info.com
The DAPI expected by the receiver.
This object is applicable only to the following three cases.
(i) optIfODUkDirectionality has the value bidirectional(3), or
(ii) optIfODUkDirectionality has the value sink(1) and
optIfODUkTCodirectional has the value true(1), or
(iii) optIfODUkDirectionality has the value source(3) and
optIfODUkTCodirectional has the value false(2).
It must not be instantiated in rows for all other cases.
This object has no effect when optIfODUkTTIMDetMode has
the value off(1).
Parsed from file rfc3591-Optical-Interface-Type.mib.txt
Company: None
Module: OPT-IF-MIB
The DAPI expected by the receiver.
This object is applicable only to the following three cases.
(i) optIfODUkDirectionality has the value bidirectional(3), or
(ii) optIfODUkDirectionality has the value sink(1) and
optIfODUkTCodirectional has the value true(1), or
(iii) optIfODUkDirectionality has the value source(3) and
optIfODUkTCodirectional has the value false(2).
It must not be instantiated in rows for all other cases.
This object has no effect when optIfODUkTTIMDetMode has
the value off(1).
Parsed from file OPT-IF-MIB.mib
Module: OPT-IF-MIB
Automatically extracted from RFC3591
optIfODUkTDAPIExpected OBJECT-TYPE SYNTAX OptIfExDAPI MAX-ACCESS read-create STATUS current DESCRIPTION "The DAPI expected by the receiver. This object is applicable only to the following three cases. (i) optIfODUkDirectionality has the value bidirectional(3), or (ii) optIfODUkDirectionality has the value sink(1) and optIfODUkTCodirectional has the value true(1), or (iii) optIfODUkDirectionality has the value source(3) and optIfODUkTCodirectional has the value false(2). It must not be instantiated in rows for all other cases. This object has no effect when optIfODUkTTIMDetMode has the value off(1)." ::= { optIfODUkTConfigEntry 4 }
optIfODUkTDAPIExpected OBJECT-TYPE SYNTAX OptIfExDAPI MAX-ACCESS read-create STATUS current DESCRIPTION "The DAPI expected by the receiver. This object is applicable only to the following three cases. (i) optIfODUkDirectionality has the value bidirectional(3), or (ii) optIfODUkDirectionality has the value sink(1) and optIfODUkTCodirectional has the value true(1), or (iii) optIfODUkDirectionality has the value source(3) and optIfODUkTCodirectional has the value false(2). It must not be instantiated in rows for all other cases. This object has no effect when optIfODUkTTIMDetMode has the value off(1)." ::= { optIfODUkTConfigEntry 4 }
Internet Assigned Numbers Authority
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.2.1.10.133.1.9.1.1.1 | optIfODUkTTcmField | 0 | 0 | Indicates the tandem connection monitoring field of the ODUk OH. Valid values are integers from 1 to 6. |
1.3.6.1.2.1.10.133.1.9.1.1.2 | optIfODUkTCodirectional | 0 | 0 | Indicates the directionality of the ODUkT termination point with respect to the associated ODUk CTP. The value true(1) means tha… |
1.3.6.1.2.1.10.133.1.9.1.1.3 | optIfODUkTTraceIdentifierTransmitted | 0 | 0 | The trace identifier transmitted. This object is applicable only to the following three cases. (i) optIfODUkDirectionality has th… |
1.3.6.1.2.1.10.133.1.9.1.1.5 | optIfODUkTSAPIExpected | 0 | 0 | The SAPI expected by the receiver. This object is applicable only to the following three cases. (i) optIfODUkDirectionality has t… |
1.3.6.1.2.1.10.133.1.9.1.1.6 | optIfODUkTTraceIdentifierAccepted | 0 | 0 | The actual trace identifier accepted. This object is applicable only to the following three cases. (i) optIfODUkDirectionality ha… |
1.3.6.1.2.1.10.133.1.9.1.1.7 | optIfODUkTTIMDetMode | 0 | 0 | Indicates the mode of the Trace Identifier Mismatch (TIM) Detection function. This object is applicable only to the following thr… |
1.3.6.1.2.1.10.133.1.9.1.1.8 | optIfODUkTTIMActEnabled | 0 | 0 | Indicates whether the Trace Identifier Mismatch (TIM) Consequent Action function is enabled. This object is applicable only to th… |
1.3.6.1.2.1.10.133.1.9.1.1.9 | optIfODUkTDEGThr | 0 | 0 | Indicates the threshold level for declaring a performance monitoring (PM) Second to be bad. A PM Second is declared bad if the p… |
1.3.6.1.2.1.10.133.1.9.1.1.10 | optIfODUkTDEGM | 0 | 0 | Indicates the threshold level for declaring a Degraded Signal defect (dDEG). A dDEG shall be declared if optIfODUkTDEGM consecut… |
1.3.6.1.2.1.10.133.1.9.1.1.11 | optIfODUkTSinkMode | 0 | 0 | This variable specifies the TCM mode at the entity. The value operational(1) means that TCM Overhead (TCMOH) processes (see ITU-T… |
1.3.6.1.2.1.10.133.1.9.1.1.12 | optIfODUkTSinkLockSignalAdminState | 0 | 0 | Provides the capability to provision the LOCK signal, which is one of the ODUk maintenance signals, at the ODUKT sink. When a Ta… |
1.3.6.1.2.1.10.133.1.9.1.1.13 | optIfODUkTSourceLockSignalAdminState | 0 | 0 | Provides the capability to provision the LOCK signal, which is one of the ODUk maintenance signals, at the source. When a Tandem … |
1.3.6.1.2.1.10.133.1.9.1.1.14 | optIfODUkTCurrentStatus | 0 | 0 | Indicates the defect condition of the entity, if any. This object is applicable only when either one of the following three cases… |
1.3.6.1.2.1.10.133.1.9.1.1.15 | optIfODUkTRowStatus | 0 | 0 | This columnar object is used for creating and deleting a conceptual row of the optIfODUkT config table. It is used to model the a… |