Reference record for OID 1.3.6.1.2.1.10.133.1.9.2.1.2



parent
1.3.6.1.2.1.10.133.1.9.2.1 (optIfODUkTNimConfigEntry)
node code
2
node name
optIfODUkTNimDirectionality
dot oid
1.3.6.1.2.1.10.133.1.9.2.1.2
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) mgmt(2) mib-2(1) transmission(10) optIfMibModule(133) optIfObjects(1) optIfODUkT(9) optIfODUkTNimConfigTable(2) optIfODUkTNimConfigEntry(1) optIfODUkTNimDirectionality(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) mgmt(2) mib(1) transmission(10) optIfMibModule(133) optIfObjects(1) optIfODUkT(9) optIfODUkTNimConfigTable(2) optIfODUkTNimConfigEntry(1) optIfODUkTNimDirectionality(2)}
  • {iso(1) org(3) dod(6) internet(1) mgmt(2) mib-2(1) transmission(10) optIfMibModule(133) optIfObjects(1) optIfODUkT(9) optIfODUkTNimConfigTable(2) optIfODUkTNimConfigEntry(1) optIfODUkTNimDirectionality(2)}
  • {iso(1) org(3) dod(6) internet(1) mgmt(2) mib(1) transmission(10) optIfMibModule(133) optIfObjects(1) optIfODUkT(9) optIfODUkTNimConfigTable(2) optIfODUkTNimConfigEntry(1) optIfODUkTNimDirectionality(2)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) mgmt(2) mib-2(1) transmission(10) optIfMibModule(133) optIfObjects(1) optIfODUkT(9) optIfODUkTNimConfigTable(2) optIfODUkTNimConfigEntry(1) optIfODUkTNimDirectionality(2)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) mgmt(2) mib(1) transmission(10) optIfMibModule(133) optIfObjects(1) optIfODUkT(9) optIfODUkTNimConfigTable(2) optIfODUkTNimConfigEntry(1) optIfODUkTNimDirectionality(2)}
  • iri oid
  • /iso/identified-organization/dod/internet/mgmt/mib-2/transmission/optIfMibModule/optIfObjects/optIfODUkT/optIfODUkTNimConfigTable/optIfODUkTNimConfigEntry/optIfODUkTNimDirectionality
  • /iso/identified-organization/dod/internet/mgmt/mib/transmission/optIfMibModule/optIfObjects/optIfODUkT/optIfODUkTNimConfigTable/optIfODUkTNimConfigEntry/optIfODUkTNimDirectionality
  • /iso/org/dod/internet/mgmt/mib-2/transmission/optIfMibModule/optIfObjects/optIfODUkT/optIfODUkTNimConfigTable/optIfODUkTNimConfigEntry/optIfODUkTNimDirectionality
  • /iso/org/dod/internet/mgmt/mib/transmission/optIfMibModule/optIfObjects/optIfODUkT/optIfODUkTNimConfigTable/optIfODUkTNimConfigEntry/optIfODUkTNimDirectionality
  • /iso/iso-identified-organization/dod/internet/mgmt/mib-2/transmission/optIfMibModule/optIfObjects/optIfODUkT/optIfODUkTNimConfigTable/optIfODUkTNimConfigEntry/optIfODUkTNimDirectionality
  • /iso/iso-identified-organization/dod/internet/mgmt/mib/transmission/optIfMibModule/optIfObjects/optIfODUkT/optIfODUkTNimConfigTable/optIfODUkTNimConfigEntry/optIfODUkTNimDirectionality
  • iri by oid_info
    /ISO/Identified-Organization/6/1/2/1/10/133/1/9/2/1/2

    Description by oid_info

    optIfODUkTNimDirectionality OBJECT-TYPE
    SYNTAX OptIfSinkOrSource
    MAX-ACCESS not-accessible
    STATUS current
    DESCRIPTION
    "Specifies the monitor point for the ODUk TCM non-intrusive
    monitoring function. The value source(2) is not allowed
    if the corresponding instance of optIfODUkDirectionality
    has the value sink(1), and the value sink(1) is not allowed
    if the corresponding instance of optIfODUkDirectionality
    has the value source(2). Either the value sink(1) or
    source(2) is allowed if the corresponding instance of
    optIfODUkDirectionality has the value bidirectional(3).
    The value sink(1) means monitoring at the sink direction
    TCM signal of the ODUk CTP.
    The value source(2) means monitoring at the source direction
    path signal of the ODUk CTP."

    View at oid-info.com

    Description by mibdepot

    Specifies the monitor point for the ODUk TCM non-intrusive
    monitoring function. The value source(2) is not allowed
    if the corresponding instance of optIfODUkDirectionality
    has the value sink(1), and the value sink(1) is not allowed
    if the corresponding instance of optIfODUkDirectionality
    has the value source(2). Either the value sink(1) or
    source(2) is allowed if the corresponding instance of
    optIfODUkDirectionality has the value bidirectional(3).
    The value sink(1) means monitoring at the sink direction
    TCM signal of the ODUk CTP.
    The value source(2) means monitoring at the source direction
    path signal of the ODUk CTP.

    Parsed from file rfc3591-Optical-Interface-Type.mib.txt
    Company: None
    Module: OPT-IF-MIB

    Description by circitor

    Specifies the monitor point for the ODUk TCM non-intrusive
    monitoring function. The value source(2) is not allowed
    if the corresponding instance of optIfODUkDirectionality
    has the value sink(1), and the value sink(1) is not allowed
    if the corresponding instance of optIfODUkDirectionality
    has the value source(2). Either the value sink(1) or
    source(2) is allowed if the corresponding instance of
    optIfODUkDirectionality has the value bidirectional(3).
    The value sink(1) means monitoring at the sink direction
    TCM signal of the ODUk CTP.
    The value source(2) means monitoring at the source direction
    path signal of the ODUk CTP.

    Parsed from file OPT-IF-MIB.mib
    Module: OPT-IF-MIB

    Information by oid_info

    Automatically extracted from RFC3591

    Information by mibdepot

    optIfODUkTNimDirectionality OBJECT-TYPE SYNTAX OptIfSinkOrSource MAX-ACCESS not-accessible STATUS current DESCRIPTION "Specifies the monitor point for the ODUk TCM non-intrusive monitoring function. The value source(2) is not allowed if the corresponding instance of optIfODUkDirectionality has the value sink(1), and the value sink(1) is not allowed if the corresponding instance of optIfODUkDirectionality has the value source(2). Either the value sink(1) or source(2) is allowed if the corresponding instance of optIfODUkDirectionality has the value bidirectional(3). The value sink(1) means monitoring at the sink direction TCM signal of the ODUk CTP. The value source(2) means monitoring at the source direction path signal of the ODUk CTP." ::= { optIfODUkTNimConfigEntry 2 }

    Information by circitor

    optIfODUkTNimDirectionality OBJECT-TYPE SYNTAX OptIfSinkOrSource MAX-ACCESS not-accessible STATUS current DESCRIPTION "Specifies the monitor point for the ODUk TCM non-intrusive monitoring function. The value source(2) is not allowed if the corresponding instance of optIfODUkDirectionality has the value sink(1), and the value sink(1) is not allowed if the corresponding instance of optIfODUkDirectionality has the value source(2). Either the value sink(1) or source(2) is allowed if the corresponding instance of optIfODUkDirectionality has the value bidirectional(3). The value sink(1) means monitoring at the sink direction TCM signal of the ODUk CTP. The value source(2) means monitoring at the source direction path signal of the ODUk CTP." ::= { optIfODUkTNimConfigEntry 2 }

    First Registration Authority (recovered by parent 1.3.6)

    Defense Communication Agency

    Current Registration Authority (recovered by parent 1.3.6.1.2)

    Internet Assigned Numbers Authority

    Brothers (10)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.2.1.10.133.1.9.2.1.1 optIfODUkTNimTcmField 0 0 Indicates the tandem connection monitoring
    field of the ODUk OH on which non-intrusive monitoring
    is performed. Valid values are…
    1.3.6.1.2.1.10.133.1.9.2.1.3 optIfODUkTNimDAPIExpected 0 0 The DAPI expected by the receiver.
    This object has no effect if optIfODUkTNimTIMDetMode has
    the value off(1) or sapi(3).
    1.3.6.1.2.1.10.133.1.9.2.1.4 optIfODUkTNimSAPIExpected 0 0 The SAPI expected by the receiver.
    This object has no effect if optIfODUkTNimTIMDetMode has
    the value off(1) or dapi(2).
    1.3.6.1.2.1.10.133.1.9.2.1.5 optIfODUkTNimTraceIdentifierAccepted 0 0 The actual trace identifier accepted. The value of
    this object is unspecified if optIfODUkTNimCurrentStatus
    has any of the bit p…
    1.3.6.1.2.1.10.133.1.9.2.1.6 optIfODUkTNimTIMDetMode 0 0 Indicates the mode of the Trace Identifier Mismatch (TIM)
    Detection function.
    1.3.6.1.2.1.10.133.1.9.2.1.7 optIfODUkTNimTIMActEnabled 0 0 Indicates whether the Trace Identifier Mismatch (TIM)
    Consequent Action function is enabled.
    1.3.6.1.2.1.10.133.1.9.2.1.8 optIfODUkTNimDEGThr 0 0 Indicates the threshold level for declaring a performance
    monitoring (PM) Second to be bad. A PM Second is declared bad if
    the p…
    1.3.6.1.2.1.10.133.1.9.2.1.9 optIfODUkTNimDEGM 0 0 Indicates the threshold level for declaring a Degraded Signal
    defect (dDEG). A dDEG shall be declared if optIfODUkTNimDEGM
    conse…
    1.3.6.1.2.1.10.133.1.9.2.1.10 optIfODUkTNimCurrentStatus 0 0 Indicates the defect condition of the entity, if any.
    The value of this object is unspecified if
    optIfODUkTNimRowStatus has any v…
    1.3.6.1.2.1.10.133.1.9.2.1.11 optIfODUkTNimRowStatus 0 0 This columnar object is used for creating and deleting a
    conceptual row of the optIfODUkTNim config table.
    It is used to model th…