optIfODUkTNimTraceIdentifierAccepted OBJECT-TYPE
SYNTAX OptIfAcTI
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The actual trace identifier accepted. The value of
this object is unspecified if optIfODUkTNimCurrentStatus
has any of the bit positions oci(0), lck(1), or ssf(5)
set or if optIfODUkTNimRowStatus has any value other
than active(1)."
View at oid-info.com
The actual trace identifier accepted. The value of
this object is unspecified if optIfODUkTNimCurrentStatus
has any of the bit positions oci(0), lck(1), or ssf(5)
set or if optIfODUkTNimRowStatus has any value other
than active(1).
Parsed from file rfc3591-Optical-Interface-Type.mib.txt
Company: None
Module: OPT-IF-MIB
The actual trace identifier accepted. The value of
this object is unspecified if optIfODUkTNimCurrentStatus
has any of the bit positions oci(0), lck(1), or ssf(5)
set or if optIfODUkTNimRowStatus has any value other
than active(1).
Parsed from file OPT-IF-MIB.mib
Module: OPT-IF-MIB
Automatically extracted from RFC3591
optIfODUkTNimTraceIdentifierAccepted OBJECT-TYPE SYNTAX OptIfAcTI MAX-ACCESS read-only STATUS current DESCRIPTION "The actual trace identifier accepted. The value of this object is unspecified if optIfODUkTNimCurrentStatus has any of the bit positions oci(0), lck(1), or ssf(5) set or if optIfODUkTNimRowStatus has any value other than active(1)." ::= { optIfODUkTNimConfigEntry 5 }
optIfODUkTNimTraceIdentifierAccepted OBJECT-TYPE SYNTAX OptIfAcTI MAX-ACCESS read-only STATUS current DESCRIPTION "The actual trace identifier accepted. The value of this object is unspecified if optIfODUkTNimCurrentStatus has any of the bit positions oci(0), lck(1), or ssf(5) set or if optIfODUkTNimRowStatus has any value other than active(1)." ::= { optIfODUkTNimConfigEntry 5 }
Internet Assigned Numbers Authority
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.2.1.10.133.1.9.2.1.1 | optIfODUkTNimTcmField | 0 | 0 | Indicates the tandem connection monitoring field of the ODUk OH on which non-intrusive monitoring is performed. Valid values are… |
1.3.6.1.2.1.10.133.1.9.2.1.2 | optIfODUkTNimDirectionality | 0 | 0 | Specifies the monitor point for the ODUk TCM non-intrusive monitoring function. The value source(2) is not allowed if the corres… |
1.3.6.1.2.1.10.133.1.9.2.1.3 | optIfODUkTNimDAPIExpected | 0 | 0 | The DAPI expected by the receiver. This object has no effect if optIfODUkTNimTIMDetMode has the value off(1) or sapi(3). |
1.3.6.1.2.1.10.133.1.9.2.1.4 | optIfODUkTNimSAPIExpected | 0 | 0 | The SAPI expected by the receiver. This object has no effect if optIfODUkTNimTIMDetMode has the value off(1) or dapi(2). |
1.3.6.1.2.1.10.133.1.9.2.1.6 | optIfODUkTNimTIMDetMode | 0 | 0 | Indicates the mode of the Trace Identifier Mismatch (TIM) Detection function. |
1.3.6.1.2.1.10.133.1.9.2.1.7 | optIfODUkTNimTIMActEnabled | 0 | 0 | Indicates whether the Trace Identifier Mismatch (TIM) Consequent Action function is enabled. |
1.3.6.1.2.1.10.133.1.9.2.1.8 | optIfODUkTNimDEGThr | 0 | 0 | Indicates the threshold level for declaring a performance monitoring (PM) Second to be bad. A PM Second is declared bad if the p… |
1.3.6.1.2.1.10.133.1.9.2.1.9 | optIfODUkTNimDEGM | 0 | 0 | Indicates the threshold level for declaring a Degraded Signal defect (dDEG). A dDEG shall be declared if optIfODUkTNimDEGM conse… |
1.3.6.1.2.1.10.133.1.9.2.1.10 | optIfODUkTNimCurrentStatus | 0 | 0 | Indicates the defect condition of the entity, if any. The value of this object is unspecified if optIfODUkTNimRowStatus has any v… |
1.3.6.1.2.1.10.133.1.9.2.1.11 | optIfODUkTNimRowStatus | 0 | 0 | This columnar object is used for creating and deleting a conceptual row of the optIfODUkTNim config table. It is used to model th… |