lmpCcUnderlyingIfIndex OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"If lmpCcIsIf is set to true(1), this object carries the
index into the iftable of the entry that represents the
LMP interface over which LMP will transmit its traffic.
If this object is set to zero, but lmpCcIsIf is set to
true(1), the control channel is not currently associated
with any underlying interface and the control channel\s
operational status must not be up(1), nor should the
control channel forward or receive traffic.
If lmpCcIsIf is set to false(2), this object should be set
to zero and should be ignored."
View at oid-info.com
If lmpCcIsIf is set to true(1), this object carries the
index into the ifTable of the entry that represents the
LMP interface over which LMP will transmit its traffic.
If this object is set to zero but lmpCcIsIf is set to
true(1), the control channel is not currently associated
with any underlying interface, and the control channel's
operational status must not be up(1); nor should the
control channel forward or receive traffic.
If lmpCcIsIf is set to false(2), this object should be set
to zero and ignored.
Parsed from file LMP-MIB.mib
Module: LMP-MIB
Automatically extracted from RFC4327
lmpCcUnderlyingIfIndex OBJECT-TYPE SYNTAX InterfaceIndexOrZero MAX-ACCESS read-create STATUS current DESCRIPTION "If lmpCcIsIf is set to true(1), this object carries the index into the ifTable of the entry that represents the LMP interface over which LMP will transmit its traffic. If this object is set to zero but lmpCcIsIf is set to true(1), the control channel is not currently associated with any underlying interface, and the control channel's operational status must not be up(1); nor should the control channel forward or receive traffic. If lmpCcIsIf is set to false(2), this object should be set to zero and ignored." ::= { lmpControlChannelEntry 2 }
Internet Assigned Numbers Authority
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.2.1.10.227.1.10.1.1 | lmpCcId | 0 | 0 | This value represents the local control channel identifier. The control channel identifier is a non-zero 32-bit number. |
1.3.6.1.2.1.10.227.1.10.1.3 | lmpCcIsIf | 0 | 0 | In implementations where the control channels are modeled as interfaces, the value of this object is true(1), and this control ch… |
1.3.6.1.2.1.10.227.1.10.1.4 | lmpCcNbrNodeId | 0 | 0 | This is the Node ID of the control channel remote node. This value either is configured or gets created by the node when a Config… |
1.3.6.1.2.1.10.227.1.10.1.5 | lmpCcRemoteId | 0 | 0 | This value represents the remote control channel identifier (32-bit number). It is determined during the negotiation phase. A v… |
1.3.6.1.2.1.10.227.1.10.1.6 | lmpCcRemoteAddressType | 0 | 0 | This value represents the remote control channel IP address type. In point-to-point configuration, this value can be set to unkn… |
1.3.6.1.2.1.10.227.1.10.1.7 | lmpCcRemoteIpAddr | 0 | 0 | This value represents the remote control channel Internet address for numbered control channel. The type of this address is dete… |
1.3.6.1.2.1.10.227.1.10.1.8 | lmpCcSetupRole | 0 | 0 | The role that this node should take during establishment of this control channel. An active node will initiate establishment. A… |
1.3.6.1.2.1.10.227.1.10.1.9 | lmpCcAuthentication | 0 | 0 | This object indicates whether the control channel must use authentication. |
1.3.6.1.2.1.10.227.1.10.1.10 | lmpCcHelloInterval | 0 | 0 | This object specifies the value of the HelloInterval parameter. The default value for this object should be set to lmpCcHelloInt… |
1.3.6.1.2.1.10.227.1.10.1.11 | lmpCcHelloIntervalMin | 0 | 0 | This object specifies the minimum value for the HelloInterval parameter. The default value for this object should be set to lmpC… |
1.3.6.1.2.1.10.227.1.10.1.12 | lmpCcHelloIntervalMax | 0 | 0 | This object specifies the maximum value for the HelloInterval parameter. The default value for this object should be set to lmpC… |
1.3.6.1.2.1.10.227.1.10.1.13 | lmpCcHelloIntervalNegotiated | 0 | 0 | Once the control channel is active, this object represents the negotiated HelloInterval value. |
1.3.6.1.2.1.10.227.1.10.1.14 | lmpCcHelloDeadInterval | 0 | 0 | This object specifies the value of the HelloDeadInterval parameter. The default value for this object should be set to lmpCcHell… |
1.3.6.1.2.1.10.227.1.10.1.15 | lmpCcHelloDeadIntervalMin | 0 | 0 | This object specifies the minimum value for the HelloDeadInterval parameter. The default value for this object should be set to … |
1.3.6.1.2.1.10.227.1.10.1.16 | lmpCcHelloDeadIntervalMax | 0 | 0 | This object specifies the maximum value for the HelloDeadInterval parameter. The default value for this object should be set to … |
1.3.6.1.2.1.10.227.1.10.1.17 | lmpCcHelloDeadIntervalNegotiated | 0 | 0 | Once the control channel is active, this object represents the negotiated HelloDeadInterval value. |
1.3.6.1.2.1.10.227.1.10.1.18 | lmpCcLastChange | 0 | 0 | The value of sysUpTime at the time the control channel entered its current operational state. If the current state was entered p… |
1.3.6.1.2.1.10.227.1.10.1.19 | lmpCcAdminStatus | 0 | 0 | The desired operational status of this control channel. |
1.3.6.1.2.1.10.227.1.10.1.20 | lmpCcOperStatus | 0 | 0 | The actual operational status of this control channel. |
1.3.6.1.2.1.10.227.1.10.1.21 | lmpCcRowStatus | 0 | 0 | This variable is used to create, modify, and/or delete a row in this table. None of the writable objects in a row can be changed… |
1.3.6.1.2.1.10.227.1.10.1.22 | lmpCcStorageType | 0 | 0 | The storage type for this conceptual row in the lmpControlChannelTable. Conceptual rows having the value 'permanent' need not al… |