lmpCcIsIf OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"In implementations where the control channels are modeled
as interfaces, the value of this object is true(1) and
this control channel is represented by an interface in
the interfaces group table as indicated by the value of
lmpCcUnderlyingIfIndex. If control channels are not
modeled as interfaces, the value of this object is
false(2) and there is no corresponding interface for
this control channel in the interfaces group table,
and the value of lmpCcUnderlyingIfIndex should be
ignored."
View at oid-info.com
In implementations where the control channels are modeled
as interfaces, the value of this object is true(1), and
this control channel is represented by an interface in
the interfaces group table as indicated by the value of
lmpCcUnderlyingIfIndex. If control channels are not
modeled as interfaces, the value of this object is
false(2), and there is no corresponding interface for
this control channel in the interfaces group table;
the value of lmpCcUnderlyingIfIndex should be
ignored.
Parsed from file LMP-MIB.mib
Module: LMP-MIB
Automatically extracted from RFC4327
lmpCcIsIf OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "In implementations where the control channels are modeled as interfaces, the value of this object is true(1), and this control channel is represented by an interface in the interfaces group table as indicated by the value of lmpCcUnderlyingIfIndex. If control channels are not modeled as interfaces, the value of this object is false(2), and there is no corresponding interface for this control channel in the interfaces group table; the value of lmpCcUnderlyingIfIndex should be ignored." ::= { lmpControlChannelEntry 3 }
Internet Assigned Numbers Authority
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.2.1.10.227.1.10.1.1 | lmpCcId | 0 | 0 | This value represents the local control channel identifier. The control channel identifier is a non-zero 32-bit number. |
1.3.6.1.2.1.10.227.1.10.1.2 | lmpCcUnderlyingIfIndex | 0 | 0 | If lmpCcIsIf is set to true(1), this object carries the index into the ifTable of the entry that represents the LMP interface ove… |
1.3.6.1.2.1.10.227.1.10.1.4 | lmpCcNbrNodeId | 0 | 0 | This is the Node ID of the control channel remote node. This value either is configured or gets created by the node when a Config… |
1.3.6.1.2.1.10.227.1.10.1.5 | lmpCcRemoteId | 0 | 0 | This value represents the remote control channel identifier (32-bit number). It is determined during the negotiation phase. A v… |
1.3.6.1.2.1.10.227.1.10.1.6 | lmpCcRemoteAddressType | 0 | 0 | This value represents the remote control channel IP address type. In point-to-point configuration, this value can be set to unkn… |
1.3.6.1.2.1.10.227.1.10.1.7 | lmpCcRemoteIpAddr | 0 | 0 | This value represents the remote control channel Internet address for numbered control channel. The type of this address is dete… |
1.3.6.1.2.1.10.227.1.10.1.8 | lmpCcSetupRole | 0 | 0 | The role that this node should take during establishment of this control channel. An active node will initiate establishment. A… |
1.3.6.1.2.1.10.227.1.10.1.9 | lmpCcAuthentication | 0 | 0 | This object indicates whether the control channel must use authentication. |
1.3.6.1.2.1.10.227.1.10.1.10 | lmpCcHelloInterval | 0 | 0 | This object specifies the value of the HelloInterval parameter. The default value for this object should be set to lmpCcHelloInt… |
1.3.6.1.2.1.10.227.1.10.1.11 | lmpCcHelloIntervalMin | 0 | 0 | This object specifies the minimum value for the HelloInterval parameter. The default value for this object should be set to lmpC… |
1.3.6.1.2.1.10.227.1.10.1.12 | lmpCcHelloIntervalMax | 0 | 0 | This object specifies the maximum value for the HelloInterval parameter. The default value for this object should be set to lmpC… |
1.3.6.1.2.1.10.227.1.10.1.13 | lmpCcHelloIntervalNegotiated | 0 | 0 | Once the control channel is active, this object represents the negotiated HelloInterval value. |
1.3.6.1.2.1.10.227.1.10.1.14 | lmpCcHelloDeadInterval | 0 | 0 | This object specifies the value of the HelloDeadInterval parameter. The default value for this object should be set to lmpCcHell… |
1.3.6.1.2.1.10.227.1.10.1.15 | lmpCcHelloDeadIntervalMin | 0 | 0 | This object specifies the minimum value for the HelloDeadInterval parameter. The default value for this object should be set to … |
1.3.6.1.2.1.10.227.1.10.1.16 | lmpCcHelloDeadIntervalMax | 0 | 0 | This object specifies the maximum value for the HelloDeadInterval parameter. The default value for this object should be set to … |
1.3.6.1.2.1.10.227.1.10.1.17 | lmpCcHelloDeadIntervalNegotiated | 0 | 0 | Once the control channel is active, this object represents the negotiated HelloDeadInterval value. |
1.3.6.1.2.1.10.227.1.10.1.18 | lmpCcLastChange | 0 | 0 | The value of sysUpTime at the time the control channel entered its current operational state. If the current state was entered p… |
1.3.6.1.2.1.10.227.1.10.1.19 | lmpCcAdminStatus | 0 | 0 | The desired operational status of this control channel. |
1.3.6.1.2.1.10.227.1.10.1.20 | lmpCcOperStatus | 0 | 0 | The actual operational status of this control channel. |
1.3.6.1.2.1.10.227.1.10.1.21 | lmpCcRowStatus | 0 | 0 | This variable is used to create, modify, and/or delete a row in this table. None of the writable objects in a row can be changed… |
1.3.6.1.2.1.10.227.1.10.1.22 | lmpCcStorageType | 0 | 0 | The storage type for this conceptual row in the lmpControlChannelTable. Conceptual rows having the value 'permanent' need not al… |