Reference record for OID 1.3.6.1.2.1.10.227.2.1.2


parent
1.3.6.1.2.1.10.227.2.1 (lmpCompliances)
node code
2
node name
lmpModuleReadOnlyCompliance
dot oid
1.3.6.1.2.1.10.227.2.1.2
type
MODULE-COMPLIANCE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) mgmt(2) mib-2(1) transmission(10) lmpMIB(227) lmpConformance(2) lmpCompliances(1) lmpModuleReadOnlyCompliance(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) mgmt(2) mib(1) transmission(10) lmpMIB(227) lmpConformance(2) lmpCompliances(1) lmpModuleReadOnlyCompliance(2)}
  • {iso(1) org(3) dod(6) internet(1) mgmt(2) mib-2(1) transmission(10) lmpMIB(227) lmpConformance(2) lmpCompliances(1) lmpModuleReadOnlyCompliance(2)}
  • {iso(1) org(3) dod(6) internet(1) mgmt(2) mib(1) transmission(10) lmpMIB(227) lmpConformance(2) lmpCompliances(1) lmpModuleReadOnlyCompliance(2)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) mgmt(2) mib-2(1) transmission(10) lmpMIB(227) lmpConformance(2) lmpCompliances(1) lmpModuleReadOnlyCompliance(2)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) mgmt(2) mib(1) transmission(10) lmpMIB(227) lmpConformance(2) lmpCompliances(1) lmpModuleReadOnlyCompliance(2)}
  • iri oid
  • /iso/identified-organization/dod/internet/mgmt/mib-2/transmission/lmpMIB/lmpConformance/lmpCompliances/lmpModuleReadOnlyCompliance
  • /iso/identified-organization/dod/internet/mgmt/mib/transmission/lmpMIB/lmpConformance/lmpCompliances/lmpModuleReadOnlyCompliance
  • /iso/org/dod/internet/mgmt/mib-2/transmission/lmpMIB/lmpConformance/lmpCompliances/lmpModuleReadOnlyCompliance
  • /iso/org/dod/internet/mgmt/mib/transmission/lmpMIB/lmpConformance/lmpCompliances/lmpModuleReadOnlyCompliance
  • /iso/iso-identified-organization/dod/internet/mgmt/mib-2/transmission/lmpMIB/lmpConformance/lmpCompliances/lmpModuleReadOnlyCompliance
  • /iso/iso-identified-organization/dod/internet/mgmt/mib/transmission/lmpMIB/lmpConformance/lmpCompliances/lmpModuleReadOnlyCompliance
  • iri by oid_info
    /ISO/Identified-Organization/6/1/2/1/10/227/2/1/2

    Description by oid_info

    lmpModuleReadOnlyCompliance MODULE-COMPLIANCE
    STATUS current
    DESCRIPTION
    "Compliance statement for agents that support the
    monitoring of the LMP MIB."
    MODULE -- this module
    -- The mandatory groups have to be implemented
    -- by all LMP-enabled devices. However, they may all be supported
    -- as read-only objects in the case where manual
    -- configuration is not supported.
    MANDATORY-GROUPS { lmpNodeGroup,
    lmpControlChannelGroup,
    lmpLinkPropertyCorrelationGroup,
    lmpPerfGroup,
    lmpTeLinkGroup,
    lmpDataLinkGroup }
    GROUP lmpCcIsNotInterfaceGroup
    DESCRIPTION
    "This group is mandatory for devices that support
    control channels that are not interfaces, in addition to
    lmpControlChannelGroup. The following constraints apply:
    lmpCcIsIf must at least be read-only returning false(1)."
    GROUP lmpCcIsInterfaceGroup
    DESCRIPTION
    "This group is mandatory for devices that support
    control channels that are interfaces, in addition to
    lmpControlChannelGroup. The following constraints apply:
    lmpCcIsIf must at least be read-only returning true(2)."
    GROUP lmpLinkVerificationGroup
    DESCRIPTION
    "This group is mandatory for devices that support
    the link verification procedure."
    GROUP lmpNotificationGroup
    DESCRIPTION
    "This group is optional."
    -- Scalars
    OBJECT lmpAdminStatus
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT lmpGlobalLinkVerificationInterval
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT lmpCcHelloIntervalDefault
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT lmpCcHelloIntervalDefaultMin
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT lmpCcHelloIntervalDefaultMax
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT lmpCcHelloDeadIntervalDefault
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT lmpCcHelloDeadIntervalDefaultMin
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT lmpCcHelloDeadIntervalDefaultMax
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT lmpNotificationMaxRate
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    -- lmpNbrTable
    OBJECT lmpNbrRetransmitInterval
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT lmpNbrRetryLimit
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT lmpNbrRetransmitDelta
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT lmpNbrRowStatus
    SYNTAX RowStatus { active(1) }
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required, and active(1) is the
    only status that needs to be supported."
    OBJECT lmpNbrStorageType
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    -- lmpControlChannelTable
    OBJECT lmpCcUnderlyingIfIndex
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT lmpCcIsIf
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT lmpCcNbrNodeId
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT lmpCcRemoteAddressType
    SYNTAX INTEGER { unknown(0), ipv4(1), ipv6(2) }
    MIN-ACCESS read-only
    DESCRIPTION
    "Only ipv4(1) and ipv6(2) address types need to be
    supported for non-point-to-point configurations."
    OBJECT lmpCcRemoteIpAddr
    SYNTAX InetAddress (SIZE(0|4|16))
    MIN-ACCESS read-only
    DESCRIPTION
    "The size of the IP address depends on the address type."
    OBJECT lmpCcSetupRole
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT lmpCcAuthentication
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT lmpCcHelloIntervalMin
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT lmpCcHelloIntervalMax
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT lmpCcHelloDeadIntervalMin
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT lmpCcHelloDeadIntervalMax
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT lmpCcRowStatus
    SYNTAX RowStatus { active(1) }
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required, and active(1) is the
    only status that needs to be supported."
    OBJECT lmpCcOperStatus
    SYNTAX INTEGER { up(1), down(2) }
    DESCRIPTION
    "A value of configSnd(3), configRcv(4), active(5),
    goingDown(6) need not be supported."
    OBJECT lmpCcStorageType
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    -- lmpLinkVerificationTable
    OBJECT lmpLinkVerifyInterval
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT lmpLinkVerifyDeadInterval
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT lmpLinkVerifyAllLinks
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    -- lmpTeLinkTable
    OBJECT lmpTeLinkNbrRemoteNodeId
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required if the link verification
    procedure is enabled."
    OBJECT lmpTeLinkVerification
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT lmpTeLinkFaultManagement
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT lmpTeLinkDwdm
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT lmpTeLinkOperStatus
    SYNTAX INTEGER { up(1), down(2), degraded(5) }
    DESCRIPTION
    "The testing(3) and init(4) state need not be supported."
    OBJECT lmpTeLinkRowStatus
    SYNTAX RowStatus { active(1) }
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required, and active(1) is the
    only status that needs to be supported."
    OBJECT lmpTeLinkStorageType
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    -- lmpTeLinkVerificationTable
    OBJECT lmpLinkVerifyTransmissionRate
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT lmpLinkVerifyWavelength
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT lmpLinkVerifyRowStatus
    SYNTAX RowStatus { active(1) }
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required, and active(1) is the
    only status that needs to be supported."
    OBJECT lmpLinkVerifyStorageType
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    -- lmpDataLinkTable
    OBJECT lmpDataLinkAddressType
    SYNTAX INTEGER { unknown(0), ipv4(1), ipv6(2) }
    MIN-ACCESS read-only
    DESCRIPTION
    "Only ipv4(1) and ipv6(2) address types need to be
    supported for numbered links. For unnumbered links, the
    unknown(0) address type needs to be supported."
    OBJECT lmpDataLinkIpAddr
    SYNTAX InetAddress (SIZE(0|4|16))
    MIN-ACCESS read-only
    DESCRIPTION
    "Size of data-bearing link IP address depends on type
    of data-bearing link. Data-bearing link IP address size
    is zero if link is unnumbered, four if link IP address is
    IPv4, and sixteen if link IP address is IPv6."
    OBJECT lmpDataLinkRemoteIpAddress
    SYNTAX InetAddress (SIZE(0|4|16))
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required if the link verification
    procedure is enabled."
    OBJECT lmpDataLinkRemoteIfId
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required if the link verification
    procedure is enabled."
    OBJECT lmpDataLinkEncodingType
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT lmpDataLinkActiveOperStatus
    SYNTAX INTEGER { upAlloc(1), upFree(2), down(3) }
    DESCRIPTION
    "A value of testing(4) need not be supported."
    OBJECT lmpDataLinkPassiveOperStatus
    SYNTAX INTEGER { upAlloc(1), upFree(2), down(3) }
    DESCRIPTION
    "A value of psvTst(4) need not be supported."
    OBJECT lmpDataLinkRowStatus
    SYNTAX RowStatus { active(1) }
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required, and active(1) is the
    only status that needs to be supported."
    OBJECT lmpDataLinkStorageType
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."

    View at oid-info.com

    Description by mibdepot

    Compliance statement for agents that support the
    monitoring of the LMP MIB.

    Parsed from file rfc4631-Link-Management-Protocol-LMP.mib.txt
    Company: None
    Module: LMP-MIB

    Description by circitor

    Compliance statement for agents that support the
    monitoring of the LMP MIB.

    Parsed from file LMP-MIB.mib
    Module: LMP-MIB

    Information by oid_info

    Automatically extracted from RFC4327

    Information by mibdepot

    lmpModuleReadOnlyCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "Compliance statement for agents that support the monitoring of the LMP MIB." MODULE MANDATORY-GROUPS { lmpNodeGroup, lmpControlChannelGroup, lmpLinkPropertyCorrelationGroup, lmpPerfGroup, lmpTeLinkGroup, lmpDataLinkGroup } GROUP lmpCcIsNotInterfaceGroup DESCRIPTION "This group is mandatory for devices that support control channels that are not interfaces, in addition to lmpControlChannelGroup. The following constraint applies: lmpCcIsIf must at least be read-only, returning false(2)." GROUP lmpCcIsInterfaceGroup DESCRIPTION "This group is mandatory for devices that support control channels that are interfaces, in addition to lmpControlChannelGroup. The following constraint applies: lmpCcIsIf must at least be read-only, returning true(1)." GROUP lmpLinkVerificationGroup DESCRIPTION "This group is mandatory for devices that support the link verification procedure." GROUP lmpNotificationGroup DESCRIPTION "This group is optional." OBJECT lmpAdminStatus MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpGlobalLinkVerificationInterval MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpCcHelloIntervalDefault MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpCcHelloIntervalDefaultMin MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpCcHelloIntervalDefaultMax MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpCcHelloDeadIntervalDefault MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpCcHelloDeadIntervalDefaultMin MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpCcHelloDeadIntervalDefaultMax MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpNotificationMaxRate MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpNbrRetransmitInterval MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpNbrRetryLimit MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpNbrRetransmitDelta MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpNbrRowStatus SYNTAX RowStatus { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required, and active(1) is the only status that needs to be supported." OBJECT lmpNbrStorageType MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpCcUnderlyingIfIndex MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpCcIsIf MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpCcNbrNodeId MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpCcRemoteAddressType SYNTAX INTEGER { unknown(0), ipv4(1), ipv6(2) } MIN-ACCESS read-only DESCRIPTION "Only ipv4(1) and ipv6(2) address types need to be supported for non-point-to-point configurations." OBJECT lmpCcRemoteIpAddr SYNTAX InetAddress (SIZE(0|4|16)) MIN-ACCESS read-only DESCRIPTION "The size of the IP address depends on the address type." OBJECT lmpCcSetupRole MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpCcAuthentication MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpCcHelloIntervalMin MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpCcHelloIntervalMax MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpCcHelloDeadIntervalMin MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpCcHelloDeadIntervalMax MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpCcRowStatus SYNTAX RowStatus { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required, and active(1) is the only status that needs to be supported." OBJECT lmpCcOperStatus SYNTAX INTEGER { up(1), down(2) } DESCRIPTION "A value of configSnd(3), configRcv(4), active(5), or goingDown(6) need not be supported." OBJECT lmpCcStorageType MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpLinkVerifyInterval MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpLinkVerifyDeadInterval MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpLinkVerifyAllLinks MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpTeLinkNbrRemoteNodeId MIN-ACCESS read-only DESCRIPTION "Write access is not required if the link verification procedure is enabled." OBJECT lmpTeLinkVerification MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpTeLinkFaultManagement MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpTeLinkDwdm MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpTeLinkOperStatus SYNTAX INTEGER { up(1), down(2), degraded(5) } DESCRIPTION "The testing(3) and init(4) state need not be supported." OBJECT lmpTeLinkRowStatus SYNTAX RowStatus { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required, and active(1) is the only status that needs to be supported." OBJECT lmpTeLinkStorageType MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpLinkVerifyTransmissionRate MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpLinkVerifyWavelength MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpLinkVerifyRowStatus SYNTAX RowStatus { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required, and active(1) is the only status that needs to be supported." OBJECT lmpLinkVerifyStorageType MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpDataLinkAddressType SYNTAX INTEGER { unknown(0), ipv4(1), ipv6(2) } MIN-ACCESS read-only DESCRIPTION "Only ipv4(1) and ipv6(2) address types need to be supported for numbered links. For unnumbered links, the unknown(0) address type needs to be supported." OBJECT lmpDataLinkIpAddr SYNTAX InetAddress (SIZE(0|4|16)) MIN-ACCESS read-only DESCRIPTION "The size of the data-bearing link IP address depends on the type of data-bearing link. Data-bearing link IP address size is zero if the link is unnumbered, four if the link IP address is IPv4, and sixteen if the link IP address is IPv6." OBJECT lmpDataLinkRemoteIpAddress SYNTAX InetAddress (SIZE(0|4|16)) MIN-ACCESS read-only DESCRIPTION "Write access is not required if the link verification procedure is enabled." OBJECT lmpDataLinkRemoteIfId MIN-ACCESS read-only DESCRIPTION "Write access is not required if the link verification procedure is enabled." OBJECT lmpDataLinkEncodingType MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpDataLinkActiveOperStatus SYNTAX INTEGER { upAlloc(1), upFree(2), down(3) } DESCRIPTION "A value of testing(4) need not be supported." OBJECT lmpDataLinkPassiveOperStatus SYNTAX INTEGER { upAlloc(1), upFree(2), down(3) } DESCRIPTION "A value of psvTst(4) need not be supported." OBJECT lmpDataLinkRowStatus SYNTAX RowStatus { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required, and active(1) is the only status that needs to be supported." OBJECT lmpDataLinkStorageType MIN-ACCESS read-only DESCRIPTION "Write access is not required." ::= { lmpCompliances 2 }

    Information by circitor

    lmpModuleReadOnlyCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "Compliance statement for agents that support the monitoring of the LMP MIB." MODULE MANDATORY-GROUPS { lmpNodeGroup, lmpControlChannelGroup, lmpLinkPropertyCorrelationGroup, lmpPerfGroup, lmpTeLinkGroup, lmpDataLinkGroup } GROUP lmpCcIsNotInterfaceGroup DESCRIPTION "This group is mandatory for devices that support control channels that are not interfaces, in addition to lmpControlChannelGroup. The following constraint applies: lmpCcIsIf must at least be read-only, returning false(2)." GROUP lmpCcIsInterfaceGroup DESCRIPTION "This group is mandatory for devices that support control channels that are interfaces, in addition to lmpControlChannelGroup. The following constraint applies: lmpCcIsIf must at least be read-only, returning true(1)." GROUP lmpLinkVerificationGroup DESCRIPTION "This group is mandatory for devices that support the link verification procedure." GROUP lmpNotificationGroup DESCRIPTION "This group is optional." OBJECT lmpAdminStatus MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpGlobalLinkVerificationInterval MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpCcHelloIntervalDefault MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpCcHelloIntervalDefaultMin MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpCcHelloIntervalDefaultMax MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpCcHelloDeadIntervalDefault MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpCcHelloDeadIntervalDefaultMin MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpCcHelloDeadIntervalDefaultMax MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpNotificationMaxRate MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpNbrRetransmitInterval MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpNbrRetryLimit MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpNbrRetransmitDelta MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpNbrRowStatus SYNTAX RowStatus { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required, and active(1) is the only status that needs to be supported." OBJECT lmpNbrStorageType MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpCcUnderlyingIfIndex MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpCcIsIf MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpCcNbrNodeId MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpCcRemoteAddressType SYNTAX INTEGER { unknown(0), ipv4(1), ipv6(2) } MIN-ACCESS read-only DESCRIPTION "Only ipv4(1) and ipv6(2) address types need to be supported for non-point-to-point configurations." OBJECT lmpCcRemoteIpAddr SYNTAX InetAddress (SIZE(0|4|16)) MIN-ACCESS read-only DESCRIPTION "The size of the IP address depends on the address type." OBJECT lmpCcSetupRole MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpCcAuthentication MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpCcHelloIntervalMin MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpCcHelloIntervalMax MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpCcHelloDeadIntervalMin MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpCcHelloDeadIntervalMax MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpCcRowStatus SYNTAX RowStatus { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required, and active(1) is the only status that needs to be supported." OBJECT lmpCcOperStatus SYNTAX INTEGER { up(1), down(2) } DESCRIPTION "A value of configSnd(3), configRcv(4), active(5), or goingDown(6) need not be supported." OBJECT lmpCcStorageType MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpLinkVerifyInterval MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpLinkVerifyDeadInterval MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpLinkVerifyAllLinks MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpTeLinkNbrRemoteNodeId MIN-ACCESS read-only DESCRIPTION "Write access is not required if the link verification procedure is enabled." OBJECT lmpTeLinkVerification MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpTeLinkFaultManagement MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpTeLinkDwdm MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpTeLinkOperStatus SYNTAX INTEGER { up(1), down(2), degraded(5) } DESCRIPTION "The testing(3) and init(4) state need not be supported." OBJECT lmpTeLinkRowStatus SYNTAX RowStatus { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required, and active(1) is the only status that needs to be supported." OBJECT lmpTeLinkStorageType MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpLinkVerifyTransmissionRate MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpLinkVerifyWavelength MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpLinkVerifyRowStatus SYNTAX RowStatus { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required, and active(1) is the only status that needs to be supported." OBJECT lmpLinkVerifyStorageType MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpDataLinkAddressType SYNTAX INTEGER { unknown(0), ipv4(1), ipv6(2) } MIN-ACCESS read-only DESCRIPTION "Only ipv4(1) and ipv6(2) address types need to be supported for numbered links. For unnumbered links, the unknown(0) address type needs to be supported." OBJECT lmpDataLinkIpAddr SYNTAX InetAddress (SIZE(0|4|16)) MIN-ACCESS read-only DESCRIPTION "The size of the data-bearing link IP address depends on the type of data-bearing link. Data-bearing link IP address size is zero if the link is unnumbered, four if the link IP address is IPv4, and sixteen if the link IP address is IPv6." OBJECT lmpDataLinkRemoteIpAddress SYNTAX InetAddress (SIZE(0|4|16)) MIN-ACCESS read-only DESCRIPTION "Write access is not required if the link verification procedure is enabled." OBJECT lmpDataLinkRemoteIfId MIN-ACCESS read-only DESCRIPTION "Write access is not required if the link verification procedure is enabled." OBJECT lmpDataLinkEncodingType MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT lmpDataLinkActiveOperStatus SYNTAX INTEGER { upAlloc(1), upFree(2), down(3) } DESCRIPTION "A value of testing(4) need not be supported." OBJECT lmpDataLinkPassiveOperStatus SYNTAX INTEGER { upAlloc(1), upFree(2), down(3) } DESCRIPTION "A value of psvTst(4) need not be supported." OBJECT lmpDataLinkRowStatus SYNTAX RowStatus { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required, and active(1) is the only status that needs to be supported." OBJECT lmpDataLinkStorageType MIN-ACCESS read-only DESCRIPTION "Write access is not required." ::= { lmpCompliances 2 }

    First Registration Authority (recovered by parent 1.3.6)

    Defense Communication Agency

    Current Registration Authority (recovered by parent 1.3.6.1.2)

    Internet Assigned Numbers Authority

    Brothers (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.2.1.10.227.2.1.1 lmpModuleFullCompliance, lmpModuleCompliance 0 0 Compliance statement for agents that support the
    LMP MIB.