The unique identification for this connectivity
unit among those within this proxy domain.
The value MUST be unique within the proxy domain
because it is the index variable for fcConnUnitTable.
The value assigned to a given conectivity unit
SHOULD be persistent across agent and unit resets.
It SHOULD be the same as fcConnUnitGlobalId
if fcConnUnitGlobalId is known and stable.
Parsed from file fcmgmt_efcm.mib.txt
Company: emc
Module: mcdata_31
fcConnUnitId OBJECT-TYPE SYNTAX OCTET STRING (SIZE (16)) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The unique identification for this connectivity unit among those within this proxy domain. The value MUST be unique within the proxy domain because it is the index variable for fcConnUnitTable. The value assigned to a given conectivity unit SHOULD be persistent across agent and unit resets. It SHOULD be the same as fcConnUnitGlobalId if fcConnUnitGlobalId is known and stable." ::= { fcConnUnitEntry 1 }
Internet Assigned Numbers Authority
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.2.1.8888.1.1.3.1.2 | fcConnUnitGlobalId | 0 | 0 | An optional global-scope identifier for this connectivity unit. It MUST be a WWN for this connectivity unit or 16 octets of value… |
1.3.6.1.2.1.8888.1.1.3.1.3 | fcConnUnitType | 0 | 0 | The type of this connectivity unit. |
1.3.6.1.2.1.8888.1.1.3.1.4 | fcConnUnitNumPorts | 0 | 0 | The number of physical ports in the connectivity unit (internal/embedded, external). |
1.3.6.1.2.1.8888.1.1.3.1.5 | fcConnUnitNumLinks, fcConnUnitState | 0 | 0 | This object reports the overall state of the connectivity unit. The meaning of all values is essentially self-explanatory. Any … |
1.3.6.1.2.1.8888.1.1.3.1.6 | fcConnUnitStatus | 0 | 0 | This object reports the overall status of the connectivity unit. The warning (4) value means that the connectivity unit needs at… |
1.3.6.1.2.1.8888.1.1.3.1.7 | fcConnUnitProduct | 0 | 0 | The connectivity unit vendor's product model name. |
1.3.6.1.2.1.8888.1.1.3.1.8 | fcConnUnitSerialNo | 0 | 0 | The serial number identification for this connectivity unit. |
1.3.6.1.2.1.8888.1.1.3.1.9 | fcConnUnitUpTime | 0 | 0 | The number of centiseconds since the last unit initialization. |
1.3.6.1.2.1.8888.1.1.3.1.10 | fcConnUnitUrl | 0 | 0 | URL to launch a management application, if applicable. Otherwise empty string. In a standalone unit, this would be the same as th… |
1.3.6.1.2.1.8888.1.1.3.1.11 | fcConnUnitDomainId | 0 | 0 | 24 bit Fibre Channel address ID of this connectivity unit. Following the fibre channel standard, the right-most bit of the right-… |
1.3.6.1.2.1.8888.1.1.3.1.12 | fcConnUnitProxyMaster | 0 | 0 | A value of 'yes' means this is the proxy master unit for a set of managed units. For example, this could be the only unit with a … |
1.3.6.1.2.1.8888.1.1.3.1.13 | fcConnUnitPrincipal | 0 | 0 | Whether this connectivity unit is the principal unit within the group of fabric elements. If this value is not applicable, return… |
1.3.6.1.2.1.8888.1.1.3.1.14 | fcConnUnitNumSensors | 0 | 0 | Number of sensors in the fcConnUnitSensorTable. |
1.3.6.1.2.1.8888.1.1.3.1.15 | fcConnUnitNumRevs | 0 | 0 | The number of revisions in the fcConnUnitRevsTable. |
1.3.6.1.2.1.8888.1.1.3.1.16 | fcConnUnitModuleId | 0 | 0 | This is a unique id, persistent between boots, that can be used to group a set of connectivity units together into a module. The … |
1.3.6.1.2.1.8888.1.1.3.1.17 | fcConnUnitName | 0 | 0 | A name for this connectivity unit. This object value should be persistent between boots. |
1.3.6.1.2.1.8888.1.1.3.1.18 | fcConnUnitInfo | 0 | 0 | Information about this connectivity unit. This object value should be persistent between boots. |
1.3.6.1.2.1.8888.1.1.3.1.19 | fcConnUnitControl | 0 | 0 | This object is used to control the addressed connectivity unit. NOTE: 'ColdStart' and 'WarmStart' are as defined in mib-2 and are … |
1.3.6.1.2.1.8888.1.1.3.1.20 | fcConnUnitContact | 0 | 0 | Contact information for this connectivity unit. The contact information is intended to facilitate contacting someone in case of p… |
1.3.6.1.2.1.8888.1.1.3.1.21 | fcConnUnitLocation | 0 | 0 | Location information for this connectivity unit. |
1.3.6.1.2.1.8888.1.1.3.1.22 | fcConnUnitEventFilter | 0 | 0 | This value defines the event severity that will be logged by this connectivity unit. All events of severity less than or equal to… |
1.3.6.1.2.1.8888.1.1.3.1.23 | fcConnUnitNumEvents | 0 | 0 | Number of events currently in the fcConnUnitEventTable. |
1.3.6.1.2.1.8888.1.1.3.1.24 | fcConnUnitMaxEvents | 0 | 0 | Max number of events that can be recorded at any one time in the fcConnUnitEventTable. |
1.3.6.1.2.1.8888.1.1.3.1.25 | fcConnUnitEventCurrID | 0 | 0 | The last used event ID (fcConnUnitEventId) recorded in the fcConnUnitEventTable. When no events are presently recorded in the fc… |
1.3.6.1.2.1.8888.1.1.3.1.27 | fcConnUnitFabricID | 0 | 0 | A globally unique value to identify the fabric that this ConnUnit belongs to, otherwise empty string. This would typically be equ… |