Reference record for OID 1.3.6.1.2.1.8888.1.1.3.1.11



parent
1.3.6.1.2.1.8888.1.1.3.1 (fcConnUnitEntry)
node code
11
node name
fcConnUnitDomainId
dot oid
1.3.6.1.2.1.8888.1.1.3.1.11
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) mgmt(2) mib-2(1) fcMgmtMIB(8888) fcMgmtObjects(1) fcMgmtConfig(1) fcConnUnitTable(3) fcConnUnitEntry(1) fcConnUnitDomainId(11)}
  • {iso(1) identified-organization(3) dod(6) internet(1) mgmt(2) mib(1) fcMgmtMIB(8888) fcMgmtObjects(1) fcMgmtConfig(1) fcConnUnitTable(3) fcConnUnitEntry(1) fcConnUnitDomainId(11)}
  • {iso(1) org(3) dod(6) internet(1) mgmt(2) mib-2(1) fcMgmtMIB(8888) fcMgmtObjects(1) fcMgmtConfig(1) fcConnUnitTable(3) fcConnUnitEntry(1) fcConnUnitDomainId(11)}
  • {iso(1) org(3) dod(6) internet(1) mgmt(2) mib(1) fcMgmtMIB(8888) fcMgmtObjects(1) fcMgmtConfig(1) fcConnUnitTable(3) fcConnUnitEntry(1) fcConnUnitDomainId(11)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) mgmt(2) mib-2(1) fcMgmtMIB(8888) fcMgmtObjects(1) fcMgmtConfig(1) fcConnUnitTable(3) fcConnUnitEntry(1) fcConnUnitDomainId(11)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) mgmt(2) mib(1) fcMgmtMIB(8888) fcMgmtObjects(1) fcMgmtConfig(1) fcConnUnitTable(3) fcConnUnitEntry(1) fcConnUnitDomainId(11)}
  • iri oid
  • /iso/identified-organization/dod/internet/mgmt/mib-2/fcMgmtMIB/fcMgmtObjects/fcMgmtConfig/fcConnUnitTable/fcConnUnitEntry/fcConnUnitDomainId
  • /iso/identified-organization/dod/internet/mgmt/mib/fcMgmtMIB/fcMgmtObjects/fcMgmtConfig/fcConnUnitTable/fcConnUnitEntry/fcConnUnitDomainId
  • /iso/org/dod/internet/mgmt/mib-2/fcMgmtMIB/fcMgmtObjects/fcMgmtConfig/fcConnUnitTable/fcConnUnitEntry/fcConnUnitDomainId
  • /iso/org/dod/internet/mgmt/mib/fcMgmtMIB/fcMgmtObjects/fcMgmtConfig/fcConnUnitTable/fcConnUnitEntry/fcConnUnitDomainId
  • /iso/iso-identified-organization/dod/internet/mgmt/mib-2/fcMgmtMIB/fcMgmtObjects/fcMgmtConfig/fcConnUnitTable/fcConnUnitEntry/fcConnUnitDomainId
  • /iso/iso-identified-organization/dod/internet/mgmt/mib/fcMgmtMIB/fcMgmtObjects/fcMgmtConfig/fcConnUnitTable/fcConnUnitEntry/fcConnUnitDomainId
  • Description by mibdepot

    24 bit Fibre Channel address ID of this connectivity unit.
    Following the fibre channel standard, the right-most bit of
    the right-most octet is for the least significant bit of the
    address value; the left-most bit of the left-most octet, if
    needed, is for the most significant bit of the address value.
    If this value is not applicable, all bits set to 1.

    Parsed from file fcmgmt_efcm.mib.txt
    Company: emc
    Module: mcdata_31

    Information by mibdepot

    fcConnUnitDomainId OBJECT-TYPE SYNTAX OCTET STRING (SIZE(3)) MAX-ACCESS read-only STATUS current DESCRIPTION "24 bit Fibre Channel address ID of this connectivity unit. Following the fibre channel standard, the right-most bit of the right-most octet is for the least significant bit of the address value; the left-most bit of the left-most octet, if needed, is for the most significant bit of the address value. If this value is not applicable, all bits set to 1." ::= { fcConnUnitEntry 11 }

    First Registration Authority (recovered by parent 1.3.6)

    Defense Communication Agency

    Current Registration Authority (recovered by parent 1.3.6.1.2)

    Internet Assigned Numbers Authority

    Brothers (25)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.2.1.8888.1.1.3.1.1 fcConnUnitId 0 0 The unique identification for this connectivity
    unit among those within this proxy domain.
    The value MUST be unique within the pr…
    1.3.6.1.2.1.8888.1.1.3.1.2 fcConnUnitGlobalId 0 0 An optional global-scope identifier for this connectivity
    unit. It MUST be a WWN for this connectivity unit or 16
    octets of value…
    1.3.6.1.2.1.8888.1.1.3.1.3 fcConnUnitType 0 0 The type of this connectivity unit.
    1.3.6.1.2.1.8888.1.1.3.1.4 fcConnUnitNumPorts 0 0 The number of physical ports in the connectivity
    unit (internal/embedded, external).
    1.3.6.1.2.1.8888.1.1.3.1.5 fcConnUnitNumLinks, fcConnUnitState 0 0 This object reports the overall state of the
    connectivity unit. The meaning of all values
    is essentially self-explanatory. Any …
    1.3.6.1.2.1.8888.1.1.3.1.6 fcConnUnitStatus 0 0 This object reports the overall status of the
    connectivity unit. The warning (4) value means
    that the connectivity unit needs at…
    1.3.6.1.2.1.8888.1.1.3.1.7 fcConnUnitProduct 0 0 The connectivity unit vendor's product model name.
    1.3.6.1.2.1.8888.1.1.3.1.8 fcConnUnitSerialNo 0 0 The serial number identification for this connectivity
    unit.
    1.3.6.1.2.1.8888.1.1.3.1.9 fcConnUnitUpTime 0 0 The number of centiseconds since the last unit
    initialization.
    1.3.6.1.2.1.8888.1.1.3.1.10 fcConnUnitUrl 0 0 URL to launch a management application, if applicable.
    Otherwise empty string. In a standalone unit, this would be
    the same as th…
    1.3.6.1.2.1.8888.1.1.3.1.12 fcConnUnitProxyMaster 0 0 A value of 'yes' means this is the proxy master unit for a
    set of managed units. For example, this could be the only
    unit with a …
    1.3.6.1.2.1.8888.1.1.3.1.13 fcConnUnitPrincipal 0 0 Whether this connectivity unit is the principal unit within
    the group of fabric elements. If this value is not applicable,
    return…
    1.3.6.1.2.1.8888.1.1.3.1.14 fcConnUnitNumSensors 0 0 Number of sensors in the fcConnUnitSensorTable.
    1.3.6.1.2.1.8888.1.1.3.1.15 fcConnUnitNumRevs 0 0 The number of revisions in the fcConnUnitRevsTable.
    1.3.6.1.2.1.8888.1.1.3.1.16 fcConnUnitModuleId 0 0 This is a unique id, persistent between boots, that can be
    used to group a set of connectivity units together into a
    module. The …
    1.3.6.1.2.1.8888.1.1.3.1.17 fcConnUnitName 0 0 A name for this connectivity unit.
    This object value should be persistent between boots.
    1.3.6.1.2.1.8888.1.1.3.1.18 fcConnUnitInfo 0 0 Information about this connectivity unit.
    This object value should be persistent between boots.
    1.3.6.1.2.1.8888.1.1.3.1.19 fcConnUnitControl 0 0 This object is used to control the addressed connectivity
    unit.

    NOTE: 'ColdStart' and 'WarmStart' are as defined in mib-2
    and are …
    1.3.6.1.2.1.8888.1.1.3.1.20 fcConnUnitContact 0 0 Contact information for this connectivity unit.
    The contact information is intended to facilitate contacting
    someone in case of p…
    1.3.6.1.2.1.8888.1.1.3.1.21 fcConnUnitLocation 0 0 Location information for this connectivity unit.
    1.3.6.1.2.1.8888.1.1.3.1.22 fcConnUnitEventFilter 0 0 This value defines the event severity that will be logged
    by this connectivity unit. All events of severity less
    than or equal to…
    1.3.6.1.2.1.8888.1.1.3.1.23 fcConnUnitNumEvents 0 0 Number of events currently in the fcConnUnitEventTable.
    1.3.6.1.2.1.8888.1.1.3.1.24 fcConnUnitMaxEvents 0 0 Max number of events that can be recorded at any one
    time in the fcConnUnitEventTable.
    1.3.6.1.2.1.8888.1.1.3.1.25 fcConnUnitEventCurrID 0 0 The last used event ID (fcConnUnitEventId) recorded in
    the fcConnUnitEventTable. When no events are presently
    recorded in the fc…
    1.3.6.1.2.1.8888.1.1.3.1.27 fcConnUnitFabricID 0 0 A globally unique value to identify the fabric that this
    ConnUnit belongs to, otherwise empty string. This would
    typically be equ…