The current operational state of the device
described by this row of the table. A value
unknown(1) indicates that the current state of the
device is unknown. running(2) indicates that the
device is up and running and that no unusual error
conditions are known. The warning(3) state
indicates that agent has been informed of an
unusual error condition by the operational software
(e.g., a disk device driver) but that the device is
still 'operational'. An example would be high
number of soft errors on a disk. A value of
testing(4), indicates that the device is not
available for use because it is in the testing
state. The state of down(5) is used only when the
agent has been informed that the device is not
available for any use.
Refer to RFC 1514, Host Resources MIB, for more details.
Additional information:
The printer's condition is mapped as follows:
eHrunning
in power save mode.
eHwarning
is not currently preventing printing. A non-critical alert
is active.
eHdown
critical alert is active. Human interaction is needed to
bring the printer to a ready state.
Parsed from file lj3200_snmp.mib.txt
Company: None
Module: LJ3200-MIB
The current operational state of the device
described by this row of the table. A value
unknown(1) indicates that the current state of the
device is unknown. running(2) indicates that the
device is up and running and that no unusual error
conditions are known. The warning(3) state
indicates that agent has been informed of an
unusual error condition by the operational software
(e.g., a disk device driver) but that the device is
still 'operational'. An example would be high
number of soft errors on a disk. A value of
testing(4), indicates that the device is not
available for use because it is in the testing
state. The state of down(5) is used only when the
agent has been informed that the device is not
available for any use.
Additional information:
The printer's condition is mapped as follows:
eHrunning
May be in power save mode.
eHwarning
not currently preventing printing. A non-critical alert is
active.
eHtesting
eHdown
critical alert is active, human interaction is needed to bring the printer to
a ready state or the printer is offline.
Parsed from file LaserJet5Si-MIB.mib
Module: LaserJet5Si-MIB
Vendor: Hewlett-Packard
Module: CLJ8500-MIB
[Automatically extracted from oidview.com]
hrdevicestatus OBJECT-TYPE SYNTAX INTEGER { eHrunning(2), eHwarning(3), eHdown(5) } ACCESS read-only STATUS mandatory DESCRIPTION "The current operational state of the device described by this row of the table. A value unknown(1) indicates that the current state of the device is unknown. running(2) indicates that the device is up and running and that no unusual error conditions are known. The warning(3) state indicates that agent has been informed of an unusual error condition by the operational software (e.g., a disk device driver) but that the device is still 'operational'. An example would be high number of soft errors on a disk. A value of testing(4), indicates that the device is not available for use because it is in the testing state. The state of down(5) is used only when the agent has been informed that the device is not available for any use. Refer to RFC 1514, Host Resources MIB, for more details. Additional information: The printer's condition is mapped as follows: eHrunning in power save mode. eHwarning is not currently preventing printing. A non-critical alert is active. eHdown critical alert is active. Human interaction is needed to bring the printer to a ready state." ::= { hrDeviceEntry 5 }
hrdevicestatus OBJECT-TYPE SYNTAX INTEGER { eHrunning(2), eHwarning(3), eHdown(5) } ACCESS read-only STATUS mandatory DESCRIPTION "The current operational state of the device described by this row of the table. A value unknown(1) indicates that the current state of the device is unknown. running(2) indicates that the device is up and running and that no unusual error conditions are known. The warning(3) state indicates that agent has been informed of an unusual error condition by the operational software (e.g., a disk device driver) but that the device is still 'operational'. An example would be high number of soft errors on a disk. A value of testing(4), indicates that the device is not available for use because it is in the testing state. The state of down(5) is used only when the agent has been informed that the device is not available for any use. Additional information: The printer's condition is mapped as follows: eHrunning May be in power save mode. eHwarning not currently preventing printing. A non-critical alert is active. eHtesting eHdown critical alert is active, human interaction is needed to bring the printer to a ready state or the printer is offline." ::= { hrDeviceEntry 5 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.11.2.3.9.4.2.3.3.2.1.5.0 | hrdevicestatus | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.11.2.3.9.4.2.3.3.2.1.1 | hrdeviceindex | 1 | 1 | A unique value for each device contained by the host. The value for each device must remain constant at least from one re-initia… |
1.3.6.1.4.1.11.2.3.9.4.2.3.3.2.1.2 | hrdevicetype | 1 | 1 | An indication of the type of device. If this value is `hrDeviceProcessor { hrDeviceTypes 3 }' then an entry exists in the hrProce… |
1.3.6.1.4.1.11.2.3.9.4.2.3.3.2.1.3 | hrdevicedescr | 1 | 1 | A textual description of this device, including the device's manufacturer and revision, and optionally, its serial number. Additio… |
1.3.6.1.4.1.11.2.3.9.4.2.3.3.2.1.4 | hrdeviceid | 1 | 1 | The product ID for this device. Additional information: The complete OID reported by this object is: .1.3.6.1.4.1.11.2.3.9.1.2.1 |
1.3.6.1.4.1.11.2.3.9.4.2.3.3.2.1.6 | hrdeviceerrors | 1 | 1 | The number of errors detected on this device. It should be noted that as this object has a SYNTAX of Counter, that it does not h… |