The number of errors detected on this device. It
should be noted that as this object has a SYNTAX
of Counter, that it does not have a defined
initial value. However, it is recommended that
this object be initialized to zero.
Refer to RFC 1514, Host Resources MIB, for more details.
Additional information:
This is the number of critical alerts that have
been entered into the alert table since the device was
powered on. The maximum value for this object is 2^32-1. At
power-on, this object will be set to zero.
Parsed from file lj3200_snmp.mib.txt
Company: None
Module: LJ3200-MIB
The number of errors detected on this device. It
should be noted that as this object has a SYNTAX
of Counter, that it does not have a defined
initial value. However, it is recommended that
this object be initialized to zero.
Additional information:
This is the number of critical alerts that have been
entered into the alert table since the device was powered on.
The maximum value for this object is 2^32-1.
Parsed from file LaserJet5Si-MIB.mib
Module: LaserJet5Si-MIB
Vendor: Hewlett-Packard
Module: CLJ8500-MIB
[Automatically extracted from oidview.com]
hrdeviceerrors OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of errors detected on this device. It should be noted that as this object has a SYNTAX of Counter, that it does not have a defined initial value. However, it is recommended that this object be initialized to zero. Refer to RFC 1514, Host Resources MIB, for more details. Additional information: This is the number of critical alerts that have been entered into the alert table since the device was powered on. The maximum value for this object is 2^32-1. At power-on, this object will be set to zero." ::= { hrDeviceEntry 6 }
hrdeviceerrors OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of errors detected on this device. It should be noted that as this object has a SYNTAX of Counter, that it does not have a defined initial value. However, it is recommended that this object be initialized to zero. Additional information: This is the number of critical alerts that have been entered into the alert table since the device was powered on. The maximum value for this object is 2^32-1." ::= { hrDeviceEntry 6 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.11.2.3.9.4.2.3.3.2.1.6.0 | hrdeviceerrors | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.11.2.3.9.4.2.3.3.2.1.1 | hrdeviceindex | 1 | 1 | A unique value for each device contained by the host. The value for each device must remain constant at least from one re-initia… |
1.3.6.1.4.1.11.2.3.9.4.2.3.3.2.1.2 | hrdevicetype | 1 | 1 | An indication of the type of device. If this value is `hrDeviceProcessor { hrDeviceTypes 3 }' then an entry exists in the hrProce… |
1.3.6.1.4.1.11.2.3.9.4.2.3.3.2.1.3 | hrdevicedescr | 1 | 1 | A textual description of this device, including the device's manufacturer and revision, and optionally, its serial number. Additio… |
1.3.6.1.4.1.11.2.3.9.4.2.3.3.2.1.4 | hrdeviceid | 1 | 1 | The product ID for this device. Additional information: The complete OID reported by this object is: .1.3.6.1.4.1.11.2.3.9.1.2.1 |
1.3.6.1.4.1.11.2.3.9.4.2.3.3.2.1.5 | hrdevicestatus | 1 | 1 | The current operational state of the device described by this row of the table. A value unknown(1) indicates that the current st… |