The Downstream Unit State is an active-value.
Note that because we have only one port per card
then this state change is exactly the same as
hcxDnstrmPortState. Note that initially standby
will be the same state as offline. Later this will
change when TX redundancy is supported. offline
is default.
Parsed from file com21.hcxtx.mib.txt
Company: None
Module: COM21-HCXTX-MIB
The Downstream Unit State is an active-value.
Note that because we have only one port per card
then this state change is exactly the same as
hcxDnstrmPortState. Note that initially standby
will be the same state as offline. Later this will
change when TX redundancy is supported. offline
is default.
Parsed from file COM21-HCXTX-MIB.mib
Module: COM21-HCXTX-MIB
Vendor: Com21
Module: COM21-HCXTX-MIB
[Automatically extracted from oidview.com]
hcxDnUnitConfigState OBJECT-TYPE SYNTAX INTEGER { offline(2000), online(2001), test(2002), standby(2003) } MAX-ACCESS read-write STATUS current DESCRIPTION " The Downstream Unit State is an active-value. Note that because we have only one port per card then this state change is exactly the same as hcxDnstrmPortState. Note that initially standby will be the same state as offline. Later this will change when TX redundancy is supported. offline is default." ::= { com21HcxDnstrmUnitGroup 7 }
hcxDnUnitConfigState OBJECT-TYPE SYNTAX INTEGER { offline(2000), online(2001), test(2002), standby(2003) } MAX-ACCESS read-write STATUS current DESCRIPTION " The Downstream Unit State is an active-value. Note that because we have only one port per card then this state change is exactly the same as hcxDnstrmPortState. Note that initially standby will be the same state as offline. Later this will change when TX redundancy is supported. offline is default." ::= { com21HcxDnstrmUnitGroup 7 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.1141.2.23.7.0 | hcxDnUnitConfigState | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.1141.2.23.1 | hcxDownstreamShelfId | 1 | 1 | contains the associated shelf id. |
1.3.6.1.4.1.1141.2.23.2 | hcxDownstreamSlotId | 1 | 1 | contains downstream slot id. |
1.3.6.1.4.1.1141.2.23.3 | hcxDownstreamHardwareVersion | 1 | 1 | contains the hardware version of the TX card. An empty string if card not present. |
1.3.6.1.4.1.1141.2.23.4 | hcxDownstreamBootVersion | 1 | 1 | contains the version of the TX card boot ROM. An empty string if card not present. |
1.3.6.1.4.1.1141.2.23.5 | hcxDnstreamUnitPrimServState | 1 | 1 | contains primary service state of the Downstream Unit. |
1.3.6.1.4.1.1141.2.23.6 | hcxDnstreamUnitSecServState | 1 | 1 | contains a string defining the secondary service states of the Downstream Unit. The substrings supported by the Downstream Unit s… |
1.3.6.1.4.1.1141.2.23.8 | hcxDnUnitRestartAction | 1 | 1 | The TX Unit Action is an active-value. The setting of this attibute to restart(2) causes the TX card to reset and download a new … |
1.3.6.1.4.1.1141.2.23.9 | hcxDnDiagTestAction | 1 | 1 | This attribute is used to invoke the internal TX diagnostic test. In order to activate this test, the card must be placed in the … |
1.3.6.1.4.1.1141.2.23.10 | hcxDnDiagTestResult | 1 | 1 | This attribute contains the result of the last TX diagnostic test. Details TBD. |
1.3.6.1.4.1.1141.2.23.11 | hcxDnTestStatusLed | 1 | 1 | The TX Test Status LED is a read-only attribute which describes the condition of the TX Test Status light emitting diode located … |
1.3.6.1.4.1.1141.2.23.12 | hcxDnFaultStatusLed | 1 | 1 | The RX Fault Status LED is a read-only attribute which describes the condition of the TX Fault Status light emitting diode locate… |
1.3.6.1.4.1.1141.2.23.13 | hcxDownstreamSerialNumber | 1 | 1 | contains the serial number of the TX card. An empty string if card not present. |