hcxDnDiagTestAction OBJECT-TYPE SYNTAX INTEGER { nil(1), execute(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " This attribute is used to invoke the internal TX diagnostic test. In order to activate this test, the card must be placed in the test state." ::= { com21HcxDnstrmUnitGroup 9 }
hcxDnDiagTestAction OBJECT-TYPE SYNTAX INTEGER { nil(1), execute(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " This attribute is used to invoke the internal TX diagnostic test. In order to activate this test, the card must be placed in the test state." ::= { com21HcxDnstrmUnitGroup 9 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.1141.2.23.9.0 | hcxDnDiagTestAction | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.1141.2.23.1 | hcxDownstreamShelfId | 1 | 1 | contains the associated shelf id. |
1.3.6.1.4.1.1141.2.23.2 | hcxDownstreamSlotId | 1 | 1 | contains downstream slot id. |
1.3.6.1.4.1.1141.2.23.3 | hcxDownstreamHardwareVersion | 1 | 1 | contains the hardware version of the TX card. An empty string if card not present. |
1.3.6.1.4.1.1141.2.23.4 | hcxDownstreamBootVersion | 1 | 1 | contains the version of the TX card boot ROM. An empty string if card not present. |
1.3.6.1.4.1.1141.2.23.5 | hcxDnstreamUnitPrimServState | 1 | 1 | contains primary service state of the Downstream Unit. |
1.3.6.1.4.1.1141.2.23.6 | hcxDnstreamUnitSecServState | 1 | 1 | contains a string defining the secondary service states of the Downstream Unit. The substrings supported by the Downstream Unit s… |
1.3.6.1.4.1.1141.2.23.7 | hcxDnUnitConfigState | 1 | 1 | The Downstream Unit State is an active-value. Note that because we have only one port per card then this state change is exactly … |
1.3.6.1.4.1.1141.2.23.8 | hcxDnUnitRestartAction | 1 | 1 | The TX Unit Action is an active-value. The setting of this attibute to restart(2) causes the TX card to reset and download a new … |
1.3.6.1.4.1.1141.2.23.10 | hcxDnDiagTestResult | 1 | 1 | This attribute contains the result of the last TX diagnostic test. Details TBD. |
1.3.6.1.4.1.1141.2.23.11 | hcxDnTestStatusLed | 1 | 1 | The TX Test Status LED is a read-only attribute which describes the condition of the TX Test Status light emitting diode located … |
1.3.6.1.4.1.1141.2.23.12 | hcxDnFaultStatusLed | 1 | 1 | The RX Fault Status LED is a read-only attribute which describes the condition of the TX Fault Status light emitting diode locate… |
1.3.6.1.4.1.1141.2.23.13 | hcxDownstreamSerialNumber | 1 | 1 | contains the serial number of the TX card. An empty string if card not present. |