Indicates the index value to identify the ATM
interface in this equipment. Each ATM interface
identified by this object is the same interface
identified by the same number of ifIndex.
Parsed from file mmpfPMib.mib.txt
Company: None
Module: MMPF-MIB
Indicates the index value to identify the ATM
interface in this equipment. Each ATM interface
identified by this object is the same interface
identified by the same number of ifIndex.
Parsed from file MMPF-MIB.mib
Module: MMPF-MIB
Vendor: NEC Corporation
Module: MMPF-MIB
[Automatically extracted from oidview.com]
mpAtmSscopIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the index value to identify the ATM interface in this equipment. Each ATM interface identified by this object is the same interface identified by the same number of ifIndex." ::= { mpAtmSscopConfigEntry 1 }
mpAtmSscopIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the index value to identify the ATM interface in this equipment. Each ATM interface identified by this object is the same interface identified by the same number of ifIndex." ::= { mpAtmSscopConfigEntry 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.119.2.3.3.13.16.3.1.2 | mpAtmSscopTimerConnectControl | 0 | 0 | It is used to set the timer value of the SSCOP connection control PDU re-sending interval timer (msec). The timer value must be … |
1.3.6.1.4.1.119.2.3.3.13.16.3.1.3 | mpAtmSscopTimerKeepalive | 0 | 0 | It is used to set the timer value of the POLL PDU re-sending interval timer, which is used when there is no SD PDU to be sent, in… |
1.3.6.1.4.1.119.2.3.3.13.16.3.1.4 | mpAtmSscopTimerNoResponse | 0 | 0 | It is used to set the timer value of the STAT PDU waiting timer (msec). This is the connection observation timer in the data tran… |
1.3.6.1.4.1.119.2.3.3.13.16.3.1.5 | mpAtmSscopTimerPoll | 0 | 0 | It is used to set the timer value of the POLL PDU sending interval timer in the data transmission phase (msec). The timer value m… |
1.3.6.1.4.1.119.2.3.3.13.16.3.1.6 | mpAtmSscopTimerIdle | 0 | 0 | It is used to set the timer value of the POLL PDU sending interval timer, which is used when there is no SD PDU to be sent, in th… |
1.3.6.1.4.1.119.2.3.3.13.16.3.1.7 | mpAtmSscopMaxConnectControl | 0 | 0 | Indicates the MAX retry count value of the SSCOP connection control PDU sending. |
1.3.6.1.4.1.119.2.3.3.13.16.3.1.8 | mpAtmSscopMaxPd | 0 | 0 | Indicates the sending timing of the POLL PDU. After the PDUs as many as the number specified by this object are sent, one POLL PD… |