It is used to set the timer value of the POLL PDU
sending interval timer, which is used when there is
no SD PDU to be sent, in the data transmission phase
(msec). The timer value must be the same as that of
the equipment connected to itself. It is possible
to set the integer of a multiple of 250.
Parsed from file mmpfPMib.mib.txt
Company: None
Module: MMPF-MIB
It is used to set the timer value of the POLL PDU
sending interval timer, which is used when there is
no SD PDU to be sent, in the data transmission phase
(msec). The timer value must be the same as that of
the equipment connected to itself. It is possible
to set the integer of a multiple of 250.
Parsed from file MMPF-MIB.mib
Module: MMPF-MIB
Vendor: NEC Corporation
Module: MMPF-MIB
[Automatically extracted from oidview.com]
mpAtmSscopTimerIdle OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "It is used to set the timer value of the POLL PDU sending interval timer, which is used when there is no SD PDU to be sent, in the data transmission phase (msec). The timer value must be the same as that of the equipment connected to itself. It is possible to set the integer of a multiple of 250." ::= { mpAtmSscopConfigEntry 6 }
mpAtmSscopTimerIdle OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "It is used to set the timer value of the POLL PDU sending interval timer, which is used when there is no SD PDU to be sent, in the data transmission phase (msec). The timer value must be the same as that of the equipment connected to itself. It is possible to set the integer of a multiple of 250." ::= { mpAtmSscopConfigEntry 6 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.119.2.3.3.13.16.3.1.1 | mpAtmSscopIfIndex | 0 | 0 | Indicates the index value to identify the ATM interface in this equipment. Each ATM interface identified by this object is the sa… |
1.3.6.1.4.1.119.2.3.3.13.16.3.1.2 | mpAtmSscopTimerConnectControl | 0 | 0 | It is used to set the timer value of the SSCOP connection control PDU re-sending interval timer (msec). The timer value must be … |
1.3.6.1.4.1.119.2.3.3.13.16.3.1.3 | mpAtmSscopTimerKeepalive | 0 | 0 | It is used to set the timer value of the POLL PDU re-sending interval timer, which is used when there is no SD PDU to be sent, in… |
1.3.6.1.4.1.119.2.3.3.13.16.3.1.4 | mpAtmSscopTimerNoResponse | 0 | 0 | It is used to set the timer value of the STAT PDU waiting timer (msec). This is the connection observation timer in the data tran… |
1.3.6.1.4.1.119.2.3.3.13.16.3.1.5 | mpAtmSscopTimerPoll | 0 | 0 | It is used to set the timer value of the POLL PDU sending interval timer in the data transmission phase (msec). The timer value m… |
1.3.6.1.4.1.119.2.3.3.13.16.3.1.7 | mpAtmSscopMaxConnectControl | 0 | 0 | Indicates the MAX retry count value of the SSCOP connection control PDU sending. |
1.3.6.1.4.1.119.2.3.3.13.16.3.1.8 | mpAtmSscopMaxPd | 0 | 0 | Indicates the sending timing of the POLL PDU. After the PDUs as many as the number specified by this object are sent, one POLL PD… |