Whether or not to trunk condition on a distant loss of frame
alarm.
Parsed from file NNCGNI00X5.mib.txt
Company: None
Module: NNCGNI00X5-MIB
Vendor: Newbridge Networks Corporation
Module: NNCGNI00X5-MIB
[Automatically extracted from oidview.com]
nncExtDs1DistantLossOfFrameConditioning OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Whether or not to trunk condition on a distant loss of frame alarm." ::= { nncExtDs1ConfigEntry 6}
nncExtDs1DistantLossOfFrameConditioning OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory ::= { nncExtDs1ConfigEntry 6}
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.123.3.10.1.1.1 | nncExtDs1ConfigIndex | 0 | 0 | The indentifier of a Ds1 line of interest, derived as for dsx1LineIndex. |
1.3.6.1.4.1.123.3.10.1.1.2 | nncExtDs1LineLength | 0 | 0 | The distance between the Ds1 interface and the CSU or repeater to which it is attached. Short is 0-100 feet, medium is 100-350 f… |
1.3.6.1.4.1.123.3.10.1.1.3 | nncExtDs1LineStatus | 0 | 0 | The status of the T1 or E1 line. It is a bit map represented as a sum and thus can indicate multiple failures simultaneously. N… |
1.3.6.1.4.1.123.3.10.1.1.4 | nncExtDs1TrunkCondEnable | 0 | 0 | Which alarm conditions will cause trunk conditioning to be applied to the link. CondNever is set if and only if no other flag is… |
1.3.6.1.4.1.123.3.10.1.1.5 | nncExtDs1LossOfFrameConditioning | 0 | 0 | Whether or not to trunk condition on a loss of frame alarm. |
1.3.6.1.4.1.123.3.10.1.1.7 | nncExtDs1FailedStateConditioning | 0 | 0 | Whether or not to trunk condition on a failed state alarm. |
1.3.6.1.4.1.123.3.10.1.1.8 | nncExtDs1ErrorRateConditioning | 0 | 0 | Whether or not to trunk condition on a failed state alarm. |
1.3.6.1.4.1.123.3.10.1.1.9 | nncExtDs1CSULoopbackConditioning | 0 | 0 | Whether or not to trunk condition on a CSU Loopback alarm. |
1.3.6.1.4.1.123.3.10.1.1.10 | nncExtDs1AlarmDeclareTime | 0 | 0 | The interval (in milliseconds) for which the local loss-of-frame condition is debounced. The debounce algorithm is as described … |
1.3.6.1.4.1.123.3.10.1.1.11 | nncExtDs1AlarmClearTime | 0 | 0 | The interval (in milliseconds) for which the reacquisition of local framing is debounced. The debounce algorithm is as described… |
1.3.6.1.4.1.123.3.10.1.1.12 | nncExtDs1UseCRCOnReframe | 0 | 0 | Whether or not the CRC is used when the specified DS1 link re-frames. This object is not valid for D4-framed T1 links. |
1.3.6.1.4.1.123.3.10.1.1.13 | nncExtDs1WorstInterval | 0 | 0 | The index into the interval table for the interval which has the TBD |
1.3.6.1.4.1.123.3.10.1.1.14 | nncExtDs1ErrorEvents | 0 | 0 | Then number of error events since the error event counter was last reset ?? |
1.3.6.1.4.1.123.3.10.1.1.15 | nncExtDs181XXCompatibility | 0 | 0 | Whether or not bit-level compatibility with an 81XX DS1 is enabled. This object is only meaningful if the DS1 is used for Nx64k … |
1.3.6.1.4.1.123.3.10.1.1.16 | nncExtDs1LoopbackConfig | 0 | 0 | The loopback which the 82X1 should be applying to the line. |
1.3.6.1.4.1.123.3.10.1.1.17 | nncExtDs1E1TrunkCondEnable | 0 | 0 | This object returns the same value as nncExtDs1TrunkCondEnable and is present for internal reasons |