brzaccVLSetDefaults OBJECT-TYPE
SYNTAX INTEGER { noDefaultSettingRequested (0),
completeFactory (1),
partialFactory (2),
completeOperator (3),
partialOperator (4),
cancelCurrentPendingRequest(5) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Applicable to all units.
Sets unit configuration to Defaults values after the
next reset.
noDefaultSettingRequested : Read-Only Option, no Default setting was Issued.
completeFactory : All parameters revert to Factory
Defaults values.
partialFactory : All parameters revert to Factory
Defaults values, except the parameters
required for maintaining wireless
connectivity.
completeOperator: All parameters revert to Operator
Defaults values.
partialOperator : All parameters revert to Operator
Defaults values, except the parameters
required for maintaining wireless
connectivity.
cancelCurrentPendingRequest : Default Setting request is cancelled."
View at oid-info.com
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.12394.1.1.2.1 | brzaccVLResetUnit | 0 | 0 | brzaccVLResetUnit OBJECT-TYPE SYNTAX INTEGER { cancel (1), resetSystemNow (2) } MAX-ACCESS read-write STATUS current DESCRIPTIO… |
1.3.6.1.4.1.12394.1.1.2.3 | brzaccVLUnitName | 0 | 0 | brzaccVLUnitName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to… |
1.3.6.1.4.1.12394.1.1.2.4 | brzaccVLFlashMemoryControl | 0 | 0 | brzaccVLFlashMemoryControl OBJECT-TYPE SYNTAX INTEGER { resetAndBootFromShadowVersion (1), useRunningVersionAfterReset (2),canc… |
1.3.6.1.4.1.12394.1.1.2.5 | brzaccVLTelnetLogoutTimer | 0 | 0 | brzaccVLTelnetLogoutTimer OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units.… |
1.3.6.1.4.1.12394.1.1.2.6 | brzaccVLSaveCurrentConfigurationAsOperatorDefaults | 0 | 0 | brzaccVLSaveCurrentConfigurationAsOperatorDefaults OBJECT-TYPE SYNTAX INTEGER { saveAsDefaults (1),cancel(2) } MAX-ACCESS read-… |
1.3.6.1.4.1.12394.1.1.2.7 | brzaccVLExitTelnet | 0 | 0 | brzaccVLExitTelnet OBJECT-TYPE SYNTAX INTEGER { cancelOperation (1), exit (2)} MAX-ACCESS read-write STATUS current DESCRIPTION… |
1.3.6.1.4.1.12394.1.1.2.8 | brzaccVLUnitPasswords | 3 | 3 | None |
1.3.6.1.4.1.12394.1.1.2.9 | brzaccVLEthernetNegotiationMode | 0 | 0 | brzaccVLEthernetNegotiationMode OBJECT-TYPE SYNTAX INTEGER { force10MbpsAndHalfDuplex (1), force10MbpsAndFullDuplex (2), force1… |
1.3.6.1.4.1.12394.1.1.2.10 | brzaccVLFTPParameters | 4 | 20 | None |
1.3.6.1.4.1.12394.1.1.2.11 | brzaccVLLoadingStatus | 0 | 0 | brzaccVLLoadingStatus OBJECT-TYPE SYNTAX INTEGER {inProcess (1), successful (2), failed (3)} MAX-ACCESS read-only STATUS curren… |
1.3.6.1.4.1.12394.1.1.2.12 | brzaccVLEventLogFileParams | 2 | 2 | None |
1.3.6.1.4.1.12394.1.1.2.13 | brzaccVLSystemLocation | 0 | 0 | brzaccVLSystemLocation OBJECT-TYPE SYNTAX DisplayString (SIZE(0..34)) MAX-ACCESS read-write STATUS current DESCRIPTION "Applica… |
1.3.6.1.4.1.12394.1.1.2.14 | brzaccVLFeatureUpgrade | 1 | 1 | None |
1.3.6.1.4.1.12394.1.1.2.15 | brzaccVLChangeUnitType | 0 | 0 | brzaccVLChangeUnitType OBJECT-TYPE SYNTAX INTEGER { bu(1), rb(2), cancel(3) } MAX-ACCESS read-write STATUS current DESCRIPTION … |
1.3.6.1.4.1.12394.1.1.2.16 | brzaccVLApWorkingMode | 0 | 0 | brzaccVLApWorkingMode OBJECT-TYPE SYNTAX INTEGER { ezMode(1), na(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Applic… |
1.3.6.1.4.1.12394.1.1.2.17 | brzaccVLLEDsettings | 2 | 7 | None |