This attribute determines the period of time in seconds that
takes for a message to be transferred over all the network.
After a 'GO' command the MUX issues a delay of
'agnCNetDelay' before activating the appropriate DB.
The delay will be applied only after performing
agnCSaveFlipDbCmd.
Parsed from file Rad0485.MIB.txt
Company: None
Module: RAD-MIB
This attribute determines the period of time in seconds that
takes for a message to be transferred over all the network.
After a 'GO' command the MUX issues a delay of
'agnCNetDelay' before activating the appropriate DB.
The delay will be applied only after performing
agnCSaveFlipDbCmd.
Parsed from file RAD-MIB.mib
Module: RAD-MIB
Vendor: Rad Data Communications Ltd.
Module: DACS-MIB
[Automatically extracted from oidview.com]
agnCNetDelay OBJECT-TYPE SYNTAX Integer32 (1..999) MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute determines the period of time in seconds that takes for a message to be transferred over all the network. After a 'GO' command the MUX issues a delay of 'agnCNetDelay' before activating the appropriate DB. The delay will be applied only after performing agnCSaveFlipDbCmd." ::= { agnFlipDbControls 6 }
agnCNetDelay OBJECT-TYPE SYNTAX Integer32 (1..999) MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute determines the period of time in seconds that takes for a message to be transferred over all the network. After a 'GO' command the MUX issues a delay of 'agnCNetDelay' before activating the appropriate DB. The delay will be applied only after performing agnCSaveFlipDbCmd." ::= { agnFlipDbControls 6 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.164.3.1.2.5.4.6.0 | agnCNetDelay | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.164.3.1.2.5.4.1 | agnCFlipDbSanityCheckCmd | 1 | 1 | Setting this attribute to on(3) will initiate the process of Sanity check on the Temp Flip Db and automatically be changed to off… |
1.3.6.1.4.1.164.3.1.2.5.4.2 | agnCSaveFlipDbCmd | 1 | 1 | Setting this attribute to on(3) will initiate the process of Sanity check on the Temp Flip Db and if it is OK, it will save the F… |
1.3.6.1.4.1.164.3.1.2.5.4.3 | agnCSaveNetCnfgIdxCmd | 1 | 1 | This attribute specifies the Id of the target NVRAM Cnfg to which the TmpCnfg should be transferred. Upon set command the MUX wil… |
1.3.6.1.4.1.164.3.1.2.5.4.4 | agnCSaveNetFlipDbCmd | 1 | 1 | Setting this attribute to on(3) will save the Temp Flip DB Into the NVRAM without actual flip. |
1.3.6.1.4.1.164.3.1.2.5.4.5 | agnCNetGoCmd | 1 | 1 | Setting this attribute to On will broadcast a 'GO' command to the network. When a Mux receives a 'GO' command it issues a delay … |
1.3.6.1.4.1.164.3.1.2.5.4.7 | agnCNetEventsBcast | 1 | 1 | This object determines if the Net Events will be Broadcasted to other Muxes of the Net or not. disabled - Net Events will NOT be … |
1.3.6.1.4.1.164.3.1.2.5.4.8 | agnCNetEventsBcastInterval | 1 | 1 | When agnCNetEventsBcast is enabled, this object determines the interval of time in seconds, between two consecutive Net Events tr… |