When agnCNetEventsBcast is enabled, this object determines
the interval of time in seconds, between two consecutive
Net Events transferred over the network.
Default=40 sec.
The interval will be applied only after performing
agnCSaveFlipDbCmd.
Parsed from file Rad0485.MIB.txt
Company: None
Module: RAD-MIB
When agnCNetEventsBcast is enabled, this object determines
the interval of time in seconds, between two consecutive
Net Events transferred over the network.
Default=40 sec.
The interval will be applied only after performing
agnCSaveFlipDbCmd.
Parsed from file RAD-MIB.mib
Module: RAD-MIB
Vendor: Rad Data Communications Ltd.
Module: DACS-MIB
[Automatically extracted from oidview.com]
agnCNetEventsBcastInterval OBJECT-TYPE SYNTAX Integer32 (10..60) MAX-ACCESS read-write STATUS current DESCRIPTION "When agnCNetEventsBcast is enabled, this object determines the interval of time in seconds, between two consecutive Net Events transferred over the network. Default=40 sec. The interval will be applied only after performing agnCSaveFlipDbCmd." ::= { agnFlipDbControls 8 }
agnCNetEventsBcastInterval OBJECT-TYPE SYNTAX Integer32 (10..60) MAX-ACCESS read-write STATUS current DESCRIPTION "When agnCNetEventsBcast is enabled, this object determines the interval of time in seconds, between two consecutive Net Events transferred over the network. Default=40 sec. The interval will be applied only after performing agnCSaveFlipDbCmd." ::= { agnFlipDbControls 8 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.164.3.1.2.5.4.8.0 | agnCNetEventsBcastInterval | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.164.3.1.2.5.4.1 | agnCFlipDbSanityCheckCmd | 1 | 1 | Setting this attribute to on(3) will initiate the process of Sanity check on the Temp Flip Db and automatically be changed to off… |
1.3.6.1.4.1.164.3.1.2.5.4.2 | agnCSaveFlipDbCmd | 1 | 1 | Setting this attribute to on(3) will initiate the process of Sanity check on the Temp Flip Db and if it is OK, it will save the F… |
1.3.6.1.4.1.164.3.1.2.5.4.3 | agnCSaveNetCnfgIdxCmd | 1 | 1 | This attribute specifies the Id of the target NVRAM Cnfg to which the TmpCnfg should be transferred. Upon set command the MUX wil… |
1.3.6.1.4.1.164.3.1.2.5.4.4 | agnCSaveNetFlipDbCmd | 1 | 1 | Setting this attribute to on(3) will save the Temp Flip DB Into the NVRAM without actual flip. |
1.3.6.1.4.1.164.3.1.2.5.4.5 | agnCNetGoCmd | 1 | 1 | Setting this attribute to On will broadcast a 'GO' command to the network. When a Mux receives a 'GO' command it issues a delay … |
1.3.6.1.4.1.164.3.1.2.5.4.6 | agnCNetDelay | 1 | 1 | This attribute determines the period of time in seconds that takes for a message to be transferred over all the network. After a … |
1.3.6.1.4.1.164.3.1.2.5.4.7 | agnCNetEventsBcast | 1 | 1 | This object determines if the Net Events will be Broadcasted to other Muxes of the Net or not. disabled - Net Events will NOT be … |