Reference record for OID 1.3.6.1.4.1.164.3.3.3.2.2.1



parent
1.3.6.1.4.1.164.3.3.3.2.2 (prtT1E1CnfgTable)
node code
1
node name
prtT1E1CnfgEntry
dot oid
1.3.6.1.4.1.164.3.3.3.2.2.1
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) rad(164) radWan(3) dacsMux(3) prtDacsMux(3) prtT1E1(2) prtT1E1CnfgTable(2) prtT1E1CnfgEntry(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) rad(164) radWan(3) dacsMux(3) prtDacsMux(3) prtT1E1(2) prtT1E1CnfgTable(2) prtT1E1CnfgEntry(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) rad(164) radWan(3) dacsMux(3) prtDacsMux(3) prtT1E1(2) prtT1E1CnfgTable(2) prtT1E1CnfgEntry(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) rad(164) radWan(3) dacsMux(3) prtDacsMux(3) prtT1E1(2) prtT1E1CnfgTable(2) prtT1E1CnfgEntry(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) rad(164) radWan(3) dacsMux(3) prtDacsMux(3) prtT1E1(2) prtT1E1CnfgTable(2) prtT1E1CnfgEntry(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) rad(164) radWan(3) dacsMux(3) prtDacsMux(3) prtT1E1(2) prtT1E1CnfgTable(2) prtT1E1CnfgEntry(1)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/rad/radWan/dacsMux/prtDacsMux/prtT1E1/prtT1E1CnfgTable/prtT1E1CnfgEntry
  • /iso/identified-organization/dod/internet/private/enterprises/rad/radWan/dacsMux/prtDacsMux/prtT1E1/prtT1E1CnfgTable/prtT1E1CnfgEntry
  • /iso/org/dod/internet/private/enterprise/rad/radWan/dacsMux/prtDacsMux/prtT1E1/prtT1E1CnfgTable/prtT1E1CnfgEntry
  • /iso/org/dod/internet/private/enterprises/rad/radWan/dacsMux/prtDacsMux/prtT1E1/prtT1E1CnfgTable/prtT1E1CnfgEntry
  • /iso/iso-identified-organization/dod/internet/private/enterprise/rad/radWan/dacsMux/prtDacsMux/prtT1E1/prtT1E1CnfgTable/prtT1E1CnfgEntry
  • /iso/iso-identified-organization/dod/internet/private/enterprises/rad/radWan/dacsMux/prtDacsMux/prtT1E1/prtT1E1CnfgTable/prtT1E1CnfgEntry
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/164/3/3/3/2/2/1

    Description by mibdepot

    An entry in the T1/E1 port configuration table.

    Parsed from file Rad0485.MIB.txt
    Company: None
    Module: RAD-MIB

    Description by circitor

    An entry in the T1/E1 port configuration table.

    Parsed from file RAD-MIB.mib
    Module: RAD-MIB

    Information by oid_info

    Vendor: Rad Data Communications Ltd.
    Module: DACS-MIB

    [Automatically extracted from oidview.com]

    Information by mibdepot

    prtT1E1CnfgEntry OBJECT-TYPE SYNTAX PrtT1E1CnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " An entry in the T1/E1 port configuration table." INDEX { prtT1E1CnfgIdx, prtT1E1PrtIdx } ::= { prtT1E1CnfgTable 1}

    Information by circitor

    prtT1E1CnfgEntry OBJECT-TYPE SYNTAX PrtT1E1CnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " An entry in the T1/E1 port configuration table." INDEX { prtT1E1CnfgIdx, prtT1E1PrtIdx } ::= { prtT1E1CnfgTable 1}

    First Registration Authority (recovered by parent 1.3.6.1.4.1.164)

    Brighitte Shalom

    Current Registration Authority (recovered by parent 1.3.6.1.4.1.164)

    Smadar Tauber

    Children (32)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.164.3.3.3.2.2.1.1 prtT1E1CnfgIdx 0 0 This attribute indicates the Idx of the Config being accessed.
    Idx of 255 relates to the Temporary (Scratch) Config.
    1.3.6.1.4.1.164.3.3.3.2.2.1.2 prtT1E1PrtIdx 0 0 This attribute indicates a unique port number.
    The same numbering as for prtGenPrtIdx.
    The valid port number depends on the IO s…
    1.3.6.1.4.1.164.3.3.3.2.2.1.3 prtT1E1Slt 0 0 This attribute indicates a unique number to identify the slot where
    the card is inserted in.
    When the unit is stand-alone, this o…
    1.3.6.1.4.1.164.3.3.3.2.2.1.4 prtT1E1LineType 0 0 This variable indicates the variety of T1/E1
    Line implementing this circuit. The type of
    circuit affects the number of bit…
    1.3.6.1.4.1.164.3.3.3.2.2.1.5 prtT1E1LineCode 0 0 This variable describes the variety of Zero
    Code Suppression used on the link, which in
    turn affects a number of its chara…
    1.3.6.1.4.1.164.3.3.3.2.2.1.6 prtT1E1SignalMode 0 0 'none' indicates that no bits are reserved for
    signaling on this channel.

    'robbedBit' indicates that T1 Robbed Bit Signaling is i…
    1.3.6.1.4.1.164.3.3.3.2.2.1.7 prtT1E1Fdl 0 0 This bitmap describes the use of the facili-
    ties data link, and is the sum of the capabili-
    ties:

    'other' indicates that a prot…
    1.3.6.1.4.1.164.3.3.3.2.2.1.8 prtT1E1FdlMode 0 0 Fdl Mode of the T1 selected port.
    notApplicable - will be used for an E1 port.
    1.3.6.1.4.1.164.3.3.3.2.2.1.9 prtT1E1Sync 0 0 This object enables returning to normal operation, after
    the end of a main/sub link red alarm event, in reduced time.
    'tr62411' -…
    1.3.6.1.4.1.164.3.3.3.2.2.1.10 prtT1E1CGA 0 0 This object selects the method used to signal the CGA state
    to the other end, through the main/sub link.
    'none' - non-transparen…
    1.3.6.1.4.1.164.3.3.3.2.2.1.11 prtT1E1IdleCode 0 0 This object selects the code transmitted to fill idle
    (unused) time slots in the main link frame.
    Valid range: (0 - FF HEX) .
    1.3.6.1.4.1.164.3.3.3.2.2.1.12 prtT1E1OosSignal 0 0 'idle' = '0' = on-hook, idle state
    'busy' = '1' = off-hook, busy state
    'forcedIdle' = SP = both A and B signaling bits are forced…
    1.3.6.1.4.1.164.3.3.3.2.2.1.13 prtT1E1VoiceOos 0 0 Voice Out-Of-Service code. Valid range: (0 - FF HEX).
    For agents that do not support this feature, the value will
    always be 0.
    1.3.6.1.4.1.164.3.3.3.2.2.1.14 prtT1E1DataOos 0 0 Data Out-Of-Service code. Valid range: (0 - FF HEX).
    For agents that do not support this feature, the value will
    always be 0.
    1.3.6.1.4.1.164.3.3.3.2.2.1.15 prtT1E1LineLengthMask 0 0 This attribute is the line length mask parameter used only
    for T1/DSU interfaces.
    len400p533ft=length range: 400ft to 533ft
    'fcc68…
    1.3.6.1.4.1.164.3.3.3.2.2.1.16 prtT1E1TxGainMask 0 0 This attribute is the tx gain mask parameter (dB), used
    only for T1/CSU interfaces.
    1.3.6.1.4.1.164.3.3.3.2.2.1.17 prtT1E1InbandMng 0 0 A unique number to identify an Inband management over the
    link.
    internal - supported by KM-2100 only. It means that the managemen…
    1.3.6.1.4.1.164.3.3.3.2.2.1.18 prtT1E1InbandMngRate 0 0 A unique number to identify the rate of the Inband management.
    It is required only for E1 links and is applicable only when
    prtEx…
    1.3.6.1.4.1.164.3.3.3.2.2.1.19 prtT1E1DedicatedTs 0 0 The value is differently determined for different products.
    There are two methods:

    1) A unique number to identify Dedicated TS of…
    1.3.6.1.4.1.164.3.3.3.2.2.1.20 prtT1E1InbandMngRoutProt 0 0 Inband Mng Routing Protocol of the port.
    When prtT1E1InbandMng is 'dedicatedPpp'-'proprietary' and
    'rip2' are applicable.
    For othe…
    1.3.6.1.4.1.164.3.3.3.2.2.1.21 prtT1E1LinkMode 0 0 regular - TSs are connected by user via TS Assignment only
    transparent - when a port with this Link Mode is connected to an
    inter…
    1.3.6.1.4.1.164.3.3.3.2.2.1.22 prtT1E1Multiplier 0 0 The data rate of each TS. The multiplier values
    can be 56 kbps or 64 kbps. For T1 only.
    1.3.6.1.4.1.164.3.3.3.2.2.1.23 prtT1E1RxGain 0 0 This attribute is the rx volume (dB).
    1.3.6.1.4.1.164.3.3.3.2.2.1.24 prtT1E1RAI 0 0 Remote Alarm Signal
    1.3.6.1.4.1.164.3.3.3.2.2.1.25 prtT1E1LineMode 0 0 Interface type of the port.
    For T1 - csu, dsu are the valid values
    For E1 - dsu, ltu are the valid values
    1.3.6.1.4.1.164.3.3.3.2.2.1.26 prtT1E1TS0SaBits 0 0 This object is applicable only for E1 ports. For T1, string size will be 0.
    For E1, it enables user to select the use of TS0 Sa …
    1.3.6.1.4.1.164.3.3.3.2.2.1.27 prtT1E1ConnectedTS 0 0 This parameter indicates if there is any connected TS for this interface.
    1.3.6.1.4.1.164.3.3.3.2.2.1.28 prtT1E1Ts0SaBit 0 0 This parameter indicates whether to send TS 0, or not.
    noMng= TS 0 is looped, therefore not sent.
    mng= TS 0 isn't looped, therefo…
    1.3.6.1.4.1.164.3.3.3.2.2.1.29 prtT1E1SameFeCnfg 0 0 This parameter indicates whether the same E1 configuration
    parameters and TS assignment are set both to the local
    and remote devi…
    1.3.6.1.4.1.164.3.3.3.2.2.1.30 prtT1E1RemCrc4 0 0 This object indicates whether the E1 of the Remote device
    connected to this E1 port, will have CRC-4 or not.
    1.3.6.1.4.1.164.3.3.3.2.2.1.31 prtT1E1MaxTSs 0 0 This object is applicable only for DXC D4T1, D4E1, D8T1, D8E1
    external ports and D8GSL internal E1 ports.
    It is relevant only whe…
    1.3.6.1.4.1.164.3.3.3.2.2.1.32 prtT1E1EocTsConfig 0 0 This object indicates whether the use of EOC for TS Configuration
    is enabled or not.