Reference record for OID 1.3.6.1.4.1.164.3.3.3.2.2.1.4



parent
1.3.6.1.4.1.164.3.3.3.2.2.1 (prtT1E1CnfgEntry)
node code
4
node name
prtT1E1LineType
dot oid
1.3.6.1.4.1.164.3.3.3.2.2.1.4
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) rad(164) radWan(3) dacsMux(3) prtDacsMux(3) prtT1E1(2) prtT1E1CnfgTable(2) prtT1E1CnfgEntry(1) prtT1E1LineType(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) rad(164) radWan(3) dacsMux(3) prtDacsMux(3) prtT1E1(2) prtT1E1CnfgTable(2) prtT1E1CnfgEntry(1) prtT1E1LineType(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) rad(164) radWan(3) dacsMux(3) prtDacsMux(3) prtT1E1(2) prtT1E1CnfgTable(2) prtT1E1CnfgEntry(1) prtT1E1LineType(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) rad(164) radWan(3) dacsMux(3) prtDacsMux(3) prtT1E1(2) prtT1E1CnfgTable(2) prtT1E1CnfgEntry(1) prtT1E1LineType(4)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) rad(164) radWan(3) dacsMux(3) prtDacsMux(3) prtT1E1(2) prtT1E1CnfgTable(2) prtT1E1CnfgEntry(1) prtT1E1LineType(4)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) rad(164) radWan(3) dacsMux(3) prtDacsMux(3) prtT1E1(2) prtT1E1CnfgTable(2) prtT1E1CnfgEntry(1) prtT1E1LineType(4)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/rad/radWan/dacsMux/prtDacsMux/prtT1E1/prtT1E1CnfgTable/prtT1E1CnfgEntry/prtT1E1LineType
  • /iso/identified-organization/dod/internet/private/enterprises/rad/radWan/dacsMux/prtDacsMux/prtT1E1/prtT1E1CnfgTable/prtT1E1CnfgEntry/prtT1E1LineType
  • /iso/org/dod/internet/private/enterprise/rad/radWan/dacsMux/prtDacsMux/prtT1E1/prtT1E1CnfgTable/prtT1E1CnfgEntry/prtT1E1LineType
  • /iso/org/dod/internet/private/enterprises/rad/radWan/dacsMux/prtDacsMux/prtT1E1/prtT1E1CnfgTable/prtT1E1CnfgEntry/prtT1E1LineType
  • /iso/iso-identified-organization/dod/internet/private/enterprise/rad/radWan/dacsMux/prtDacsMux/prtT1E1/prtT1E1CnfgTable/prtT1E1CnfgEntry/prtT1E1LineType
  • /iso/iso-identified-organization/dod/internet/private/enterprises/rad/radWan/dacsMux/prtDacsMux/prtT1E1/prtT1E1CnfgTable/prtT1E1CnfgEntry/prtT1E1LineType
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/164/3/3/3/2/2/1/4

    Description by mibdepot

    This variable indicates the variety of T1/E1
    Line implementing this circuit. The type of
    circuit affects the number of bits per second
    that the circuit can reasonably carry, as well
    as the interpretation of the usage and error
    statistics. The values, in sequence, describe:

    TITLE: SPECIFICATION:
    esf Extended SuperFrame DS1
    d4 AT&T D4 format DS1 - SF
    e1 CCITT Recommendation G.704
    (Table 4a) - G732N
    e1Crc CCITT Recommendation G.704
    (Table 4b) - G732N with CRC
    e1MF G.704 (Table 4a) with TS16
    multiframing enabled - G732S
    e1CrcMF G.704 (Table 4b) with TS16
    multiframing enabled - G732S with CRC
    unframed

    T1 - applicable values: (1),(2),(3),(8)
    E1 - applicable values: (1),(4),(5),(6),(7),(8)

    Parsed from file Rad0485.MIB.txt
    Company: None
    Module: RAD-MIB

    Description by circitor

    This variable indicates the variety of T1/E1
    Line implementing this circuit. The type of
    circuit affects the number of bits per second
    that the circuit can reasonably carry, as well
    as the interpretation of the usage and error
    statistics. The values, in sequence, describe:

    TITLE: SPECIFICATION:
    esf Extended SuperFrame DS1
    d4 AT&T D4 format DS1 - SF
    e1 CCITT Recommendation G.704
    (Table 4a) - G732N
    e1Crc CCITT Recommendation G.704
    (Table 4b) - G732N with CRC
    e1MF G.704 (Table 4a) with TS16
    multiframing enabled - G732S
    e1CrcMF G.704 (Table 4b) with TS16
    multiframing enabled - G732S with CRC
    unframed

    T1 - applicable values: (1),(2),(3),(8)
    E1 - applicable values: (1),(4),(5),(6),(7),(8)

    Parsed from file RAD-MIB.mib
    Module: RAD-MIB

    Information by oid_info

    Vendor: Rad Data Communications Ltd.
    Module: DACS-MIB

    [Automatically extracted from oidview.com]

    Information by mibdepot

    prtT1E1LineType OBJECT-TYPE SYNTAX INTEGER { other (1), esf (2), d4 (3), e1 (4), e1Crc (5), e1MF (6), e1CrcMF (7), unframed (8) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable indicates the variety of T1/E1 Line implementing this circuit. The type of circuit affects the number of bits per second that the circuit can reasonably carry, as well as the interpretation of the usage and error statistics. The values, in sequence, describe: TITLE: SPECIFICATION: esf Extended SuperFrame DS1 d4 AT&T D4 format DS1 - SF e1 CCITT Recommendation G.704 (Table 4a) - G732N e1Crc CCITT Recommendation G.704 (Table 4b) - G732N with CRC e1MF G.704 (Table 4a) with TS16 multiframing enabled - G732S e1CrcMF G.704 (Table 4b) with TS16 multiframing enabled - G732S with CRC unframed T1 - applicable values: (1),(2),(3),(8) E1 - applicable values: (1),(4),(5),(6),(7),(8) " ::= { prtT1E1CnfgEntry 4 }

    Information by circitor

    prtT1E1LineType OBJECT-TYPE SYNTAX INTEGER { other (1), esf (2), d4 (3), e1 (4), e1Crc (5), e1MF (6), e1CrcMF (7), unframed (8) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable indicates the variety of T1/E1 Line implementing this circuit. The type of circuit affects the number of bits per second that the circuit can reasonably carry, as well as the interpretation of the usage and error statistics. The values, in sequence, describe: TITLE: SPECIFICATION: esf Extended SuperFrame DS1 d4 AT&T D4 format DS1 - SF e1 CCITT Recommendation G.704 (Table 4a) - G732N e1Crc CCITT Recommendation G.704 (Table 4b) - G732N with CRC e1MF G.704 (Table 4a) with TS16 multiframing enabled - G732S e1CrcMF G.704 (Table 4b) with TS16 multiframing enabled - G732S with CRC unframed T1 - applicable values: (1),(2),(3),(8) E1 - applicable values: (1),(4),(5),(6),(7),(8) " ::= { prtT1E1CnfgEntry 4 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.164)

    Brighitte Shalom

    Current Registration Authority (recovered by parent 1.3.6.1.4.1.164)

    Smadar Tauber

    Brothers (31)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.164.3.3.3.2.2.1.1 prtT1E1CnfgIdx 0 0 This attribute indicates the Idx of the Config being accessed.
    Idx of 255 relates to the Temporary (Scratch) Config.
    1.3.6.1.4.1.164.3.3.3.2.2.1.2 prtT1E1PrtIdx 0 0 This attribute indicates a unique port number.
    The same numbering as for prtGenPrtIdx.
    The valid port number depends on the IO s…
    1.3.6.1.4.1.164.3.3.3.2.2.1.3 prtT1E1Slt 0 0 This attribute indicates a unique number to identify the slot where
    the card is inserted in.
    When the unit is stand-alone, this o…
    1.3.6.1.4.1.164.3.3.3.2.2.1.5 prtT1E1LineCode 0 0 This variable describes the variety of Zero
    Code Suppression used on the link, which in
    turn affects a number of its chara…
    1.3.6.1.4.1.164.3.3.3.2.2.1.6 prtT1E1SignalMode 0 0 'none' indicates that no bits are reserved for
    signaling on this channel.

    'robbedBit' indicates that T1 Robbed Bit Signaling is i…
    1.3.6.1.4.1.164.3.3.3.2.2.1.7 prtT1E1Fdl 0 0 This bitmap describes the use of the facili-
    ties data link, and is the sum of the capabili-
    ties:

    'other' indicates that a prot…
    1.3.6.1.4.1.164.3.3.3.2.2.1.8 prtT1E1FdlMode 0 0 Fdl Mode of the T1 selected port.
    notApplicable - will be used for an E1 port.
    1.3.6.1.4.1.164.3.3.3.2.2.1.9 prtT1E1Sync 0 0 This object enables returning to normal operation, after
    the end of a main/sub link red alarm event, in reduced time.
    'tr62411' -…
    1.3.6.1.4.1.164.3.3.3.2.2.1.10 prtT1E1CGA 0 0 This object selects the method used to signal the CGA state
    to the other end, through the main/sub link.
    'none' - non-transparen…
    1.3.6.1.4.1.164.3.3.3.2.2.1.11 prtT1E1IdleCode 0 0 This object selects the code transmitted to fill idle
    (unused) time slots in the main link frame.
    Valid range: (0 - FF HEX) .
    1.3.6.1.4.1.164.3.3.3.2.2.1.12 prtT1E1OosSignal 0 0 'idle' = '0' = on-hook, idle state
    'busy' = '1' = off-hook, busy state
    'forcedIdle' = SP = both A and B signaling bits are forced…
    1.3.6.1.4.1.164.3.3.3.2.2.1.13 prtT1E1VoiceOos 0 0 Voice Out-Of-Service code. Valid range: (0 - FF HEX).
    For agents that do not support this feature, the value will
    always be 0.
    1.3.6.1.4.1.164.3.3.3.2.2.1.14 prtT1E1DataOos 0 0 Data Out-Of-Service code. Valid range: (0 - FF HEX).
    For agents that do not support this feature, the value will
    always be 0.
    1.3.6.1.4.1.164.3.3.3.2.2.1.15 prtT1E1LineLengthMask 0 0 This attribute is the line length mask parameter used only
    for T1/DSU interfaces.
    len400p533ft=length range: 400ft to 533ft
    'fcc68…
    1.3.6.1.4.1.164.3.3.3.2.2.1.16 prtT1E1TxGainMask 0 0 This attribute is the tx gain mask parameter (dB), used
    only for T1/CSU interfaces.
    1.3.6.1.4.1.164.3.3.3.2.2.1.17 prtT1E1InbandMng 0 0 A unique number to identify an Inband management over the
    link.
    internal - supported by KM-2100 only. It means that the managemen…
    1.3.6.1.4.1.164.3.3.3.2.2.1.18 prtT1E1InbandMngRate 0 0 A unique number to identify the rate of the Inband management.
    It is required only for E1 links and is applicable only when
    prtEx…
    1.3.6.1.4.1.164.3.3.3.2.2.1.19 prtT1E1DedicatedTs 0 0 The value is differently determined for different products.
    There are two methods:

    1) A unique number to identify Dedicated TS of…
    1.3.6.1.4.1.164.3.3.3.2.2.1.20 prtT1E1InbandMngRoutProt 0 0 Inband Mng Routing Protocol of the port.
    When prtT1E1InbandMng is 'dedicatedPpp'-'proprietary' and
    'rip2' are applicable.
    For othe…
    1.3.6.1.4.1.164.3.3.3.2.2.1.21 prtT1E1LinkMode 0 0 regular - TSs are connected by user via TS Assignment only
    transparent - when a port with this Link Mode is connected to an
    inter…
    1.3.6.1.4.1.164.3.3.3.2.2.1.22 prtT1E1Multiplier 0 0 The data rate of each TS. The multiplier values
    can be 56 kbps or 64 kbps. For T1 only.
    1.3.6.1.4.1.164.3.3.3.2.2.1.23 prtT1E1RxGain 0 0 This attribute is the rx volume (dB).
    1.3.6.1.4.1.164.3.3.3.2.2.1.24 prtT1E1RAI 0 0 Remote Alarm Signal
    1.3.6.1.4.1.164.3.3.3.2.2.1.25 prtT1E1LineMode 0 0 Interface type of the port.
    For T1 - csu, dsu are the valid values
    For E1 - dsu, ltu are the valid values
    1.3.6.1.4.1.164.3.3.3.2.2.1.26 prtT1E1TS0SaBits 0 0 This object is applicable only for E1 ports. For T1, string size will be 0.
    For E1, it enables user to select the use of TS0 Sa …
    1.3.6.1.4.1.164.3.3.3.2.2.1.27 prtT1E1ConnectedTS 0 0 This parameter indicates if there is any connected TS for this interface.
    1.3.6.1.4.1.164.3.3.3.2.2.1.28 prtT1E1Ts0SaBit 0 0 This parameter indicates whether to send TS 0, or not.
    noMng= TS 0 is looped, therefore not sent.
    mng= TS 0 isn't looped, therefo…
    1.3.6.1.4.1.164.3.3.3.2.2.1.29 prtT1E1SameFeCnfg 0 0 This parameter indicates whether the same E1 configuration
    parameters and TS assignment are set both to the local
    and remote devi…
    1.3.6.1.4.1.164.3.3.3.2.2.1.30 prtT1E1RemCrc4 0 0 This object indicates whether the E1 of the Remote device
    connected to this E1 port, will have CRC-4 or not.
    1.3.6.1.4.1.164.3.3.3.2.2.1.31 prtT1E1MaxTSs 0 0 This object is applicable only for DXC D4T1, D4E1, D8T1, D8E1
    external ports and D8GSL internal E1 ports.
    It is relevant only whe…
    1.3.6.1.4.1.164.3.3.3.2.2.1.32 prtT1E1EocTsConfig 0 0 This object indicates whether the use of EOC for TS Configuration
    is enabled or not.