This attribute indicates a unique number to identify a port.
The valid port number depends on the IO slot no., the
installed card type and the port type: outside, inside,
SP.
* The inside ports will be the HS cards ports. The
convention used will be (for DXC):
- first two digits will be: (IO slot number+10)
- last one/two digits will be the port number within the
card, in even numbers:
port1 = 2
port2 = 4
port3 = 6
etc...
Example: port2 of IO slot 11 will be: 214 .
Parsed from file Rad0485.MIB.txt
Company: None
Module: RAD-MIB
This attribute indicates a unique number to identify a port.
The valid port number depends on the IO slot no., the
installed card type and the port type: outside, inside,
SP.
* The inside ports will be the HS cards ports. The
convention used will be (for DXC):
- first two digits will be: (IO slot number+10)
- last one/two digits will be the port number within the
card, in even numbers:
port1 = 2
port2 = 4
port3 = 6
etc...
Example: port2 of IO slot 11 will be: 214 .
Parsed from file RAD-MIB.mib
Module: RAD-MIB
Vendor: Rad Data Communications Ltd.
Module: DACS-MIB
[Automatically extracted from oidview.com]
prtHSPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique number to identify a port. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside, SP. * The inside ports will be the HS cards ports. The convention used will be (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 ." ::= { prtHSParamEntry 2}
prtHSPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique number to identify a port. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside, SP. * The inside ports will be the HS cards ports. The convention used will be (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 ." ::= { prtHSParamEntry 2}
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.164.3.3.3.3.1.1.1 | prtHSCnfgIdx | 0 | 0 | This attribute indicates the Idx of the Config being accessed. Idx of 255 relates to the Temporary (Scratch) Config. |
1.3.6.1.4.1.164.3.3.3.3.1.1.3 | prtHSSlt | 0 | 0 | This attribute indicates a unique number to identify the slot where the card is inserted in. When the unit is stand-alone, this o… |
1.3.6.1.4.1.164.3.3.3.3.1.1.4 | prtHSRate | 0 | 0 | This object indicates the port rate (speed). auto - rate is selected automatically by system. |
1.3.6.1.4.1.164.3.3.3.3.1.1.5 | prtHSFifoSize | 0 | 0 | This object selects the size of the user data channel buffer FIFO used in the DTE2 mode. In the other modes, buffer size is autom… |
1.3.6.1.4.1.164.3.3.3.3.1.1.6 | prtHSClkMode | 0 | 0 | Clock Mode of the user data channel. dce - DACS operates as a DCE and provides transmit and receive clocks to the synchronous use… |
1.3.6.1.4.1.164.3.3.3.3.1.1.7 | prtHSCTS | 0 | 0 | Selection of CTS line state in the user data channel. on - CTS continuously ON. rts - CTS line follows the RTS line. |
1.3.6.1.4.1.164.3.3.3.3.1.1.8 | prtHSRtsState | 0 | 0 | RTS state of the port. |
1.3.6.1.4.1.164.3.3.3.3.1.1.9 | prtHSInbandLoopback | 0 | 0 | This object indicates if Inband Loopback from the Network should be enabled or disabled. |
1.3.6.1.4.1.164.3.3.3.3.1.1.10 | prtHSInbandLoopPatternCfg | 0 | 0 | This object indicates if Inband Loop polynomial pattern will be according to RDL Loop (the standard) or User Configurated accordi… |
1.3.6.1.4.1.164.3.3.3.3.1.1.11 | prtHSInbandLoopActPattern | 0 | 0 | This object is a binary string of up to 8 bits. Though the syntax allows for any ASCII characters, for this object only '0' or '1… |
1.3.6.1.4.1.164.3.3.3.3.1.1.12 | prtHSInbandLoopDeactPattern | 0 | 0 | This object is a binary string of up to 8 bits. Though the syntax allows for any ASCII characters, for this object only '0' or '1… |
1.3.6.1.4.1.164.3.3.3.3.1.1.13 | prtHSDCD | 0 | 0 | Selection of DCD line state in the user data channel. linkOK - DCD line is ON only when active link is OK. on - DCD continuously… |