The upstream data rate limit in 64 kbps(bits per sec), the CO modem
shall forward this information to the CPE modem to be
managed there. The limit shall be set by the management
entity, which would be the maximum upstream throughput.
A zero value would disable upstream rate limiting on the port.
Parsed from file PDN-ELOOP-MIB.mib.txt
Company: paradyne
Module: PDN-ELOOP-MIB
Vendor: Paradyne
Module: PDN-ELOOP-MIB (PDN-ELOOP-MIB.mib)
Type: TABULAR
Access: read-write
Syntax: Integer32
(
0..4095 )
Automatically extracted from www.mibdepot.com
eloopCOMdmIfUpRateLimit OBJECT-TYPE SYNTAX Integer32 (0..4095) MAX-ACCESS read-write STATUS current DESCRIPTION "The upstream data rate limit in 64 kbps(bits per sec), the CO modem shall forward this information to the CPE modem to be managed there. The limit shall be set by the management entity, which would be the maximum upstream throughput. A zero value would disable upstream rate limiting on the port." DEFVAL { 0 } ::= { eloopCOMdmIfPortEntry 4 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.1795.2.24.18.4.2.2.2.1.1 | eloopCOMdmIfStackUnit | 0 | 0 | The stack unit number for the CO modem interface, this identifies the physical unit in a stacked BS24e configuration. For non-sta… |
1.3.6.1.4.1.1795.2.24.18.4.2.2.2.1.2 | eloopCOMdmIfSlot | 0 | 0 | The slot number for the CO modem interface, this identifies the switch port on a BS24e unit. |
1.3.6.1.4.1.1795.2.24.18.4.2.2.2.1.3 | eloopCOMdmIfPort | 0 | 0 | The port number on the CO modem device, this identifies the Etherloop port on a CO modem device in a either a STATMUX or a 10306/… |
1.3.6.1.4.1.1795.2.24.18.4.2.2.2.1.5 | eloopCOMdmIfDownRateLimit | 0 | 0 | The downstream data rate limit in 64 kbps (bits per sec). The CO modem manages the downstream rate limit, which is set by the man… |
1.3.6.1.4.1.1795.2.24.18.4.2.2.2.1.6 | eloopCOMdmIfUpRateThreshold | 0 | 0 | The upstream data rate threshold, which is set by the management entity, in units of 64 kbps (bits per sec). A notification is se… |
1.3.6.1.4.1.1795.2.24.18.4.2.2.2.1.7 | eloopCOMdmIfDownRateThreshold | 0 | 0 | The downstream data rat threshold, which is set by the management entity, in units of 64 kbps (bits per sec). A notification is s… |
1.3.6.1.4.1.1795.2.24.18.4.2.2.2.1.8 | eloopCOMdmIfMaxUpBurstSize | 0 | 0 | The maximum upstream burst size in 8Kb, the CO modem forwards this information to the CPE modem to be managed there. A zero value… |
1.3.6.1.4.1.1795.2.24.18.4.2.2.2.1.9 | eloopCOMdmIfMaxDownBurstSize | 0 | 0 | The maximum downstream burst size in 8Kb, the CO modem manages the burst size. A zero value clears the burst size limiting. |
1.3.6.1.4.1.1795.2.24.18.4.2.2.2.1.10 | eloopCOMdmIfRecurTrngDelay | 0 | 0 | The interval, in seconds, between training bursts. The default is 4 for 6224/12:1 and 1 for all other modems. |
1.3.6.1.4.1.1795.2.24.18.4.2.2.2.1.11 | eloopCOMdmIfForceHighSpeed | 0 | 0 | If this object is Forced, then this modem interface will always run at maximum speed. |
1.3.6.1.4.1.1795.2.24.18.4.2.2.2.1.12 | eloopCOMdmIfSecureVlan | 0 | 0 | If set to Uturns(1), . |
1.3.6.1.4.1.1795.2.24.18.4.2.2.2.1.13 | eloopCOMdmIfClearStats | 0 | 0 | If clear(2) is written to this object, the counters on this interface and the associated Ethernet port are set to 0 and a trap is… |
1.3.6.1.4.1.1795.2.24.18.4.2.2.2.1.14 | eloopCOMdmIfTrapStatus | 0 | 0 | eloopCOMdmIftrapStatus |
1.3.6.1.4.1.1795.2.24.18.4.2.2.2.1.15 | eloopCOMdmIfResetTrng | 0 | 0 | If reset(2) is written to the object, forces the port to reset and begin power-on training. |
1.3.6.1.4.1.1795.2.24.18.4.2.2.2.1.16 | eloopCOMdmIfTrngMode | 0 | 0 | eloopCOMdmIftrngMode |
1.3.6.1.4.1.1795.2.24.18.4.2.2.2.1.17 | eloopCOMdmIfStandbyTraining | 0 | 0 | To enable/disable CO Modem Standby Training. By default, the Standby Training is ENABLED, in which the CO modem passively waits f… |