Reference record for OID 1.3.6.1.4.1.18.3.4.9.4.1



parent
1.3.6.1.4.1.18.3.4.9.4 (wfDs1E1ConfigTable)
node code
1
node name
wfDs1E1ConfigEntry
dot oid
1.3.6.1.4.1.18.3.4.9.4.1
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) wellfleet(18) wfSwSeries7(3) wfLine(4) wfDs1E1Group(9) wfDs1E1ConfigTable(4) wfDs1E1ConfigEntry(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) wellfleet(18) wfSwSeries7(3) wfLine(4) wfDs1E1Group(9) wfDs1E1ConfigTable(4) wfDs1E1ConfigEntry(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) wellfleet(18) wfSwSeries7(3) wfLine(4) wfDs1E1Group(9) wfDs1E1ConfigTable(4) wfDs1E1ConfigEntry(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) wellfleet(18) wfSwSeries7(3) wfLine(4) wfDs1E1Group(9) wfDs1E1ConfigTable(4) wfDs1E1ConfigEntry(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) wellfleet(18) wfSwSeries7(3) wfLine(4) wfDs1E1Group(9) wfDs1E1ConfigTable(4) wfDs1E1ConfigEntry(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) wellfleet(18) wfSwSeries7(3) wfLine(4) wfDs1E1Group(9) wfDs1E1ConfigTable(4) wfDs1E1ConfigEntry(1)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/wellfleet/wfSwSeries7/wfLine/wfDs1E1Group/wfDs1E1ConfigTable/wfDs1E1ConfigEntry
  • /iso/identified-organization/dod/internet/private/enterprises/wellfleet/wfSwSeries7/wfLine/wfDs1E1Group/wfDs1E1ConfigTable/wfDs1E1ConfigEntry
  • /iso/org/dod/internet/private/enterprise/wellfleet/wfSwSeries7/wfLine/wfDs1E1Group/wfDs1E1ConfigTable/wfDs1E1ConfigEntry
  • /iso/org/dod/internet/private/enterprises/wellfleet/wfSwSeries7/wfLine/wfDs1E1Group/wfDs1E1ConfigTable/wfDs1E1ConfigEntry
  • /iso/iso-identified-organization/dod/internet/private/enterprise/wellfleet/wfSwSeries7/wfLine/wfDs1E1Group/wfDs1E1ConfigTable/wfDs1E1ConfigEntry
  • /iso/iso-identified-organization/dod/internet/private/enterprises/wellfleet/wfSwSeries7/wfLine/wfDs1E1Group/wfDs1E1ConfigTable/wfDs1E1ConfigEntry
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/18/3/4/9/4/1

    Description by mibdepot

    An entry in the DS1E1 config table

    Parsed from file WFMIB.asn.txt
    Company: None
    Module: Wellfleet-Series7-MIB

    Description by circitor

    An entry in the DS1E1 config table

    Parsed from file Wellfleet-DS1E1-MIB.mib
    Module: Wellfleet-DS1E1-MIB

    Information by oid_info

    Vendor: Wellfleet
    Module: Wellfleet-DS1E1-MIB

    [Automatically extracted from oidview.com]

    Information by mibdepot

    wfDs1E1ConfigEntry OBJECT-TYPE SYNTAX WfDs1E1ConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " An entry in the DS1E1 config table " INDEX { wfDs1E1ConfigPortLineNumber } ::= { wfDs1E1ConfigTable 1 }

    Information by circitor

    wfDs1E1ConfigEntry OBJECT-TYPE SYNTAX WfDs1E1ConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the DS1E1 config table" INDEX { wfDs1E1ConfigPortLineNumber } ::= { wfDs1E1ConfigTable 1 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.18)

    Caralyn Brown

    Children (14)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.18.3.4.9.4.1.1 wfDs1E1ConfigDelete 0 0 Create/Delete attribute
    1.3.6.1.4.1.18.3.4.9.4.1.2 wfDs1E1ConfigPortLineNumber 0 0 The index ID for this record. It is the line number assigned to a port
    in the wfDs1E1PortMapEntry for a port.connector pair. Its…
    1.3.6.1.4.1.18.3.4.9.4.1.3 wfDs1E1ConfigIfIndex 0 0 Currently this is the sames as wfDs1E1LinePortIndex
    1.3.6.1.4.1.18.3.4.9.4.1.4 wfDs1E1ConfigTimeElapsed 0 0 The number of seconds that have elapsed since the beginning of the
    current error-measurement period. Only relevant when the
    wfDs1…
    1.3.6.1.4.1.18.3.4.9.4.1.5 wfDs1E1ConfigValidIntervals 0 0 The number of previous intervals for which valid data was collected. The
    value will be 96 unless the interface was brought on-li…
    1.3.6.1.4.1.18.3.4.9.4.1.6 wfDs1E1ConfigLineType 0 0 This attribute is used to configure the line framing type to match
    the carrier's framing. SF and ESF are T1 framing types and th…
    1.3.6.1.4.1.18.3.4.9.4.1.7 wfDs1E1ConfigLineCoding 0 0 This variable describes the variety of Zero Code Suppression used on the
    link, which in turn affects a number of its characteris…
    1.3.6.1.4.1.18.3.4.9.4.1.8 wfDs1E1ConfigSendCode 0 0 This variable is currently read-only and it indicates what type of code is
    being sent across the DS1 interface by the device. T…
    1.3.6.1.4.1.18.3.4.9.4.1.9 wfDs1E1ConfigCircuitIdentifier 0 0 This attribute is not used and appears here as a place holder only. If it
    was implemented then it would contain the transmission…
    1.3.6.1.4.1.18.3.4.9.4.1.10 wfDs1E1ConfigLoopbackConfig 0 0 This variable represents the loopback configuration of the DS1 interface.
    The value NOLOOP indicates the port is not in loopback…
    1.3.6.1.4.1.18.3.4.9.4.1.11 wfDs1E1ConfigLineStatus 0 0 This variable is a bit-map which indicates the Line Status of the
    interface. It contains loopback, failure, received 'alarm' a…
    1.3.6.1.4.1.18.3.4.9.4.1.12 wfDs1E1ConfigSignalMode 0 0 This attribute is not implemented and exists here only as a place holder.
    1.3.6.1.4.1.18.3.4.9.4.1.13 wfDs1E1ConfigTransmitClockSource 0 0 The source of Tranmit Clock. LOOPTIMING indicates that the recovered
    receive clock is used as the transmit clock. LOCALTIMING in…
    1.3.6.1.4.1.18.3.4.9.4.1.14 wfDs1E1ConfigFdl 0 0 This attribute is used to configure the type facilities data link (FDL).
    The ANSI403 configures the port to use the FDL exchange…