This attribute is not used and appears here as a place holder only. If it
was implemented then it would contain the transmission vendor's circuit
identifier, for the purpose of facilitating troubleshooting.
Parsed from file WFMIB.asn.txt
Company: None
Module: Wellfleet-Series7-MIB
This attribute is not used and appears here as a place holder only. If it
was implemented then it would contain the transmission vendor's circuit
identifier, for the purpose of facilitating troubleshooting.
Parsed from file Wellfleet-DS1E1-MIB.mib
Module: Wellfleet-DS1E1-MIB
Vendor: Wellfleet
Module: Wellfleet-DS1E1-MIB
[Automatically extracted from oidview.com]
wfDs1E1ConfigCircuitIdentifier OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION " This attribute is not used and appears here as a place holder only. If it was implemented then it would contain the transmission vendor's circuit identifier, for the purpose of facilitating troubleshooting. " ::= { wfDs1E1ConfigEntry 9 }
wfDs1E1ConfigCircuitIdentifier OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "This attribute is not used and appears here as a place holder only. If it was implemented then it would contain the transmission vendor's circuit identifier, for the purpose of facilitating troubleshooting." ::= { wfDs1E1ConfigEntry 9 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.18.3.4.9.4.1.1 | wfDs1E1ConfigDelete | 0 | 0 | Create/Delete attribute |
1.3.6.1.4.1.18.3.4.9.4.1.2 | wfDs1E1ConfigPortLineNumber | 0 | 0 | The index ID for this record. It is the line number assigned to a port in the wfDs1E1PortMapEntry for a port.connector pair. Its… |
1.3.6.1.4.1.18.3.4.9.4.1.3 | wfDs1E1ConfigIfIndex | 0 | 0 | Currently this is the sames as wfDs1E1LinePortIndex |
1.3.6.1.4.1.18.3.4.9.4.1.4 | wfDs1E1ConfigTimeElapsed | 0 | 0 | The number of seconds that have elapsed since the beginning of the current error-measurement period. Only relevant when the wfDs1… |
1.3.6.1.4.1.18.3.4.9.4.1.5 | wfDs1E1ConfigValidIntervals | 0 | 0 | The number of previous intervals for which valid data was collected. The value will be 96 unless the interface was brought on-li… |
1.3.6.1.4.1.18.3.4.9.4.1.6 | wfDs1E1ConfigLineType | 0 | 0 | This attribute is used to configure the line framing type to match the carrier's framing. SF and ESF are T1 framing types and th… |
1.3.6.1.4.1.18.3.4.9.4.1.7 | wfDs1E1ConfigLineCoding | 0 | 0 | This variable describes the variety of Zero Code Suppression used on the link, which in turn affects a number of its characteris… |
1.3.6.1.4.1.18.3.4.9.4.1.8 | wfDs1E1ConfigSendCode | 0 | 0 | This variable is currently read-only and it indicates what type of code is being sent across the DS1 interface by the device. T… |
1.3.6.1.4.1.18.3.4.9.4.1.10 | wfDs1E1ConfigLoopbackConfig | 0 | 0 | This variable represents the loopback configuration of the DS1 interface. The value NOLOOP indicates the port is not in loopback… |
1.3.6.1.4.1.18.3.4.9.4.1.11 | wfDs1E1ConfigLineStatus | 0 | 0 | This variable is a bit-map which indicates the Line Status of the interface. It contains loopback, failure, received 'alarm' a… |
1.3.6.1.4.1.18.3.4.9.4.1.12 | wfDs1E1ConfigSignalMode | 0 | 0 | This attribute is not implemented and exists here only as a place holder. |
1.3.6.1.4.1.18.3.4.9.4.1.13 | wfDs1E1ConfigTransmitClockSource | 0 | 0 | The source of Tranmit Clock. LOOPTIMING indicates that the recovered receive clock is used as the transmit clock. LOCALTIMING in… |
1.3.6.1.4.1.18.3.4.9.4.1.14 | wfDs1E1ConfigFdl | 0 | 0 | This attribute is used to configure the type facilities data link (FDL). The ANSI403 configures the port to use the FDL exchange… |