The value of this variable indicates the PLCP
status as indicated by the three-bit PLCP LSS
code received from the remote end. Connected is
LSS code #0, linkUp is LSS code #6, and linkDown is
code #3. OtherCode means that one of the other five
possible code values is being received. OutOfFrame
means that the PLCP is in the out of frame state,
and therefore there is no code being received.
Parsed from file atm.mib.txt
Company: None
Module: Wellfleet-ATM-MIB
The value of this variable indicates the PLCP
status as indicated by the three-bit PLCP LSS
code received from the remote end. Connected is
LSS code #0, linkUp is LSS code #6, and linkDown is
code #3. OtherCode means that one of the other five
possible code values is being received. OutOfFrame
means that the PLCP is in the out of frame state,
and therefore there is no code being received.
Parsed from file Wellfleet-ATM-MIB.mib
Module: Wellfleet-ATM-MIB
Vendor: Wellfleet
Module: Wellfleet-ATM-MIB
[Automatically extracted from oidview.com]
wfAtmPlcpStatus OBJECT-TYPE SYNTAX INTEGER { connected(1), up(2), down(3), other(4), outofframe(5) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this variable indicates the PLCP status as indicated by the three-bit PLCP LSS code received from the remote end. Connected is LSS code #0, linkUp is LSS code #6, and linkDown is code #3. OtherCode means that one of the other five possible code values is being received. OutOfFrame means that the PLCP is in the out of frame state, and therefore there is no code being received." DEFVAL { down } ::= { wfAtmPlcpEntry 7 }
wfAtmPlcpStatus OBJECT-TYPE SYNTAX INTEGER { connected(1), up(2), down(3), other(4), outofframe(5) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this variable indicates the PLCP status as indicated by the three-bit PLCP LSS code received from the remote end. Connected is LSS code #0, linkUp is LSS code #6, and linkDown is code #3. OtherCode means that one of the other five possible code values is being received. OutOfFrame means that the PLCP is in the out of frame state, and therefore there is no code being received." DEFVAL { down } ::= { wfAtmPlcpEntry 7 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.18.3.5.9.5.4.1.1 | wfAtmPlcpCct | 0 | 0 | Identifies the DS1 or DS3 PLCP port for which this entry contains information. This corresponds to the Wellfleet circuit number |
1.3.6.1.4.1.18.3.5.9.5.4.1.2 | wfAtmPlcpPhysical | 0 | 0 | Identifies the OID of the first object in the standard DS1 or DS3 MIB |
1.3.6.1.4.1.18.3.5.9.5.4.1.3 | wfAtmPlcpLof | 0 | 0 | True if Loss of Frame has been detected |
1.3.6.1.4.1.18.3.5.9.5.4.1.4 | wfAtmPlcpLofCFA | 0 | 0 | True if Loss of Frame has been detected over the CFA time period |
1.3.6.1.4.1.18.3.5.9.5.4.1.5 | wfAtmPlcpYellow | 0 | 0 | True if PLCP Yellow (Remote Alarm Indication) has been detected |
1.3.6.1.4.1.18.3.5.9.5.4.1.6 | wfAtmPlcpYellowCFA | 0 | 0 | True if PLCP Yellow (Remote Alarm Indication) has been detected over the CFA time period |
1.3.6.1.4.1.18.3.5.9.5.4.1.8 | wfAtmPlcpSeconds | 0 | 0 | The count of seconds elapsed since event counting began or since the counters were last cleared. The implementation may optional… |
1.3.6.1.4.1.18.3.5.9.5.4.1.9 | wfAtmPlcpBipErrors | 0 | 0 | The count of PLCP Bit Interleaved Parity (BIP) errors detected. |
1.3.6.1.4.1.18.3.5.9.5.4.1.10 | wfAtmPlcpBipESecs | 0 | 0 | BIP Errored Seconds. The count of seconds during which one or more BIP errors were detected. |
1.3.6.1.4.1.18.3.5.9.5.4.1.11 | wfAtmPlcpBipSESecs | 0 | 0 | BIP Severely Errored Seconds. The count of seconds during which five (5) or more BIP errors were detected. |
1.3.6.1.4.1.18.3.5.9.5.4.1.12 | wfAtmPlcpFebes | 0 | 0 | The count of PLCP Far End Block Errors (FEBE) detected. |
1.3.6.1.4.1.18.3.5.9.5.4.1.13 | wfAtmPlcpFebeESecs | 0 | 0 | FEBE Errored Seconds. The count of seconds during which one or more FEBE errors were detected. |
1.3.6.1.4.1.18.3.5.9.5.4.1.14 | wfAtmPlcpFebeSESecs | 0 | 0 | FEBE Severely Errored Seconds. The count of seconds during which five (5) or more FEBE errors were detected. |
1.3.6.1.4.1.18.3.5.9.5.4.1.15 | wfAtmPlcpFrameErrors | 0 | 0 | The count of PLCP Frame bit errors detected. |
1.3.6.1.4.1.18.3.5.9.5.4.1.16 | wfAtmPlcpSevereFrameErrors | 0 | 0 | The count of PLCP Severe Frame errors (aka Out Of Frame Events) detected. |
1.3.6.1.4.1.18.3.5.9.5.4.1.17 | wfAtmPlcpSEFS | 0 | 0 | Severely Errored Framing Seconds. The count of seconds during which one or more PLCP Severe Frame errors were detected. |
1.3.6.1.4.1.18.3.5.9.5.4.1.18 | wfAtmPlcpUAS | 0 | 0 | Unavailable Seconds. The count of seconds during which the PLCP service was declared to be unavailable. |
1.3.6.1.4.1.18.3.5.9.5.4.1.19 | wfAtmPlcpLineNumber | 0 | 0 | Instance identifier. This value corresponds to the line number of the Wellfleet router. |
1.3.6.1.4.1.18.3.5.9.5.4.1.20 | wfAtmPlcpLLIndex | 0 | 0 | Instance identifier. This value corresponds to the port's llindex. The Lower layer index uniquely identifies the lower layer in c… |