Reference record for OID 1.3.6.1.4.1.18.3.5.9.5.4.1.8



parent
1.3.6.1.4.1.18.3.5.9.5.4.1 (wfAtmPlcpEntry)
node code
8
node name
wfAtmPlcpSeconds
dot oid
1.3.6.1.4.1.18.3.5.9.5.4.1.8
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) wellfleet(18) wfSwSeries7(3) wfApplication(5) wfWanGroup(9) wfAtmGroup(5) wfAtmPlcpTable(4) wfAtmPlcpEntry(1) wfAtmPlcpSeconds(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) wellfleet(18) wfSwSeries7(3) wfApplication(5) wfWanGroup(9) wfAtmGroup(5) wfAtmPlcpTable(4) wfAtmPlcpEntry(1) wfAtmPlcpSeconds(8)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) wellfleet(18) wfSwSeries7(3) wfApplication(5) wfWanGroup(9) wfAtmGroup(5) wfAtmPlcpTable(4) wfAtmPlcpEntry(1) wfAtmPlcpSeconds(8)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) wellfleet(18) wfSwSeries7(3) wfApplication(5) wfWanGroup(9) wfAtmGroup(5) wfAtmPlcpTable(4) wfAtmPlcpEntry(1) wfAtmPlcpSeconds(8)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) wellfleet(18) wfSwSeries7(3) wfApplication(5) wfWanGroup(9) wfAtmGroup(5) wfAtmPlcpTable(4) wfAtmPlcpEntry(1) wfAtmPlcpSeconds(8)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) wellfleet(18) wfSwSeries7(3) wfApplication(5) wfWanGroup(9) wfAtmGroup(5) wfAtmPlcpTable(4) wfAtmPlcpEntry(1) wfAtmPlcpSeconds(8)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/wellfleet/wfSwSeries7/wfApplication/wfWanGroup/wfAtmGroup/wfAtmPlcpTable/wfAtmPlcpEntry/wfAtmPlcpSeconds
  • /iso/identified-organization/dod/internet/private/enterprises/wellfleet/wfSwSeries7/wfApplication/wfWanGroup/wfAtmGroup/wfAtmPlcpTable/wfAtmPlcpEntry/wfAtmPlcpSeconds
  • /iso/org/dod/internet/private/enterprise/wellfleet/wfSwSeries7/wfApplication/wfWanGroup/wfAtmGroup/wfAtmPlcpTable/wfAtmPlcpEntry/wfAtmPlcpSeconds
  • /iso/org/dod/internet/private/enterprises/wellfleet/wfSwSeries7/wfApplication/wfWanGroup/wfAtmGroup/wfAtmPlcpTable/wfAtmPlcpEntry/wfAtmPlcpSeconds
  • /iso/iso-identified-organization/dod/internet/private/enterprise/wellfleet/wfSwSeries7/wfApplication/wfWanGroup/wfAtmGroup/wfAtmPlcpTable/wfAtmPlcpEntry/wfAtmPlcpSeconds
  • /iso/iso-identified-organization/dod/internet/private/enterprises/wellfleet/wfSwSeries7/wfApplication/wfWanGroup/wfAtmGroup/wfAtmPlcpTable/wfAtmPlcpEntry/wfAtmPlcpSeconds
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/18/3/5/9/5/4/1/8

    Description by mibdepot

    The count of seconds elapsed since event counting
    began or since the counters were last cleared. The
    implementation may optionally allow this variable to
    be set. If set, the set value is ignored, and this
    variable and all other event counters for this
    object are reset to zero.

    Parsed from file atm.mib.txt
    Company: None
    Module: Wellfleet-ATM-MIB

    Description by circitor

    The count of seconds elapsed since event counting
    began or since the counters were last cleared. The
    implementation may optionally allow this variable to
    be set. If set, the set value is ignored, and this
    variable and all other event counters for this
    object are reset to zero.

    Parsed from file Wellfleet-ATM-MIB.mib
    Module: Wellfleet-ATM-MIB

    Information by oid_info

    Vendor: Wellfleet
    Module: Wellfleet-ATM-MIB

    [Automatically extracted from oidview.com]

    Information by mibdepot

    wfAtmPlcpSeconds OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The count of seconds elapsed since event counting began or since the counters were last cleared. The implementation may optionally allow this variable to be set. If set, the set value is ignored, and this variable and all other event counters for this object are reset to zero." ::= { wfAtmPlcpEntry 8 }

    Information by circitor

    wfAtmPlcpSeconds OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The count of seconds elapsed since event counting began or since the counters were last cleared. The implementation may optionally allow this variable to be set. If set, the set value is ignored, and this variable and all other event counters for this object are reset to zero." ::= { wfAtmPlcpEntry 8 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.18)

    Caralyn Brown

    Brothers (19)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.18.3.5.9.5.4.1.1 wfAtmPlcpCct 0 0 Identifies the DS1 or DS3 PLCP port for which this entry
    contains information. This corresponds to the Wellfleet
    circuit number
    1.3.6.1.4.1.18.3.5.9.5.4.1.2 wfAtmPlcpPhysical 0 0 Identifies the OID of the first object in the standard
    DS1 or DS3 MIB
    1.3.6.1.4.1.18.3.5.9.5.4.1.3 wfAtmPlcpLof 0 0 True if Loss of Frame has been detected
    1.3.6.1.4.1.18.3.5.9.5.4.1.4 wfAtmPlcpLofCFA 0 0 True if Loss of Frame has been detected over the CFA time
    period
    1.3.6.1.4.1.18.3.5.9.5.4.1.5 wfAtmPlcpYellow 0 0 True if PLCP Yellow (Remote Alarm Indication) has been detected
    1.3.6.1.4.1.18.3.5.9.5.4.1.6 wfAtmPlcpYellowCFA 0 0 True if PLCP Yellow (Remote Alarm Indication) has been detected
    over the CFA time period
    1.3.6.1.4.1.18.3.5.9.5.4.1.7 wfAtmPlcpStatus 0 0 The value of this variable indicates the PLCP
    status as indicated by the three-bit PLCP LSS
    code received from the remote end. C…
    1.3.6.1.4.1.18.3.5.9.5.4.1.9 wfAtmPlcpBipErrors 0 0 The count of PLCP Bit Interleaved Parity (BIP)
    errors detected.
    1.3.6.1.4.1.18.3.5.9.5.4.1.10 wfAtmPlcpBipESecs 0 0 BIP Errored Seconds. The count of seconds during
    which one or more BIP errors were detected.
    1.3.6.1.4.1.18.3.5.9.5.4.1.11 wfAtmPlcpBipSESecs 0 0 BIP Severely Errored Seconds. The count of seconds
    during which five (5) or more BIP errors were detected.
    1.3.6.1.4.1.18.3.5.9.5.4.1.12 wfAtmPlcpFebes 0 0 The count of PLCP Far End Block Errors (FEBE)
    detected.
    1.3.6.1.4.1.18.3.5.9.5.4.1.13 wfAtmPlcpFebeESecs 0 0 FEBE Errored Seconds. The count of seconds during
    which one or more FEBE errors were detected.
    1.3.6.1.4.1.18.3.5.9.5.4.1.14 wfAtmPlcpFebeSESecs 0 0 FEBE Severely Errored Seconds. The count of seconds
    during which five (5) or more FEBE errors were detected.
    1.3.6.1.4.1.18.3.5.9.5.4.1.15 wfAtmPlcpFrameErrors 0 0 The count of PLCP Frame bit errors detected.
    1.3.6.1.4.1.18.3.5.9.5.4.1.16 wfAtmPlcpSevereFrameErrors 0 0 The count of PLCP Severe Frame errors (aka Out Of
    Frame Events) detected.
    1.3.6.1.4.1.18.3.5.9.5.4.1.17 wfAtmPlcpSEFS 0 0 Severely Errored Framing Seconds. The count of
    seconds during which one or more PLCP Severe Frame
    errors were detected.
    1.3.6.1.4.1.18.3.5.9.5.4.1.18 wfAtmPlcpUAS 0 0 Unavailable Seconds. The count of seconds during
    which the PLCP service was declared to be unavailable.
    1.3.6.1.4.1.18.3.5.9.5.4.1.19 wfAtmPlcpLineNumber 0 0 Instance identifier. This value corresponds to the line number
    of the Wellfleet router.
    1.3.6.1.4.1.18.3.5.9.5.4.1.20 wfAtmPlcpLLIndex 0 0 Instance identifier. This value corresponds to the port's
    llindex. The Lower layer index uniquely identifies the lower
    layer in c…