vci for this PVC. This value must be greater than or
equal to 32 since the first 32 vci code points have
been reserved by the ATM Forum.
Parsed from file mvstcpip.mi2.txt
Company: None
Module: IBMTCPIPMVS-MIB
vci for this PVC. This value must be greater than or
equal to 32 since the first 32 vci code points have
been reserved by the ATM Forum.
Parsed from file IBMTCPIPMVS-MIB.mib
Module: IBMTCPIPMVS-MIB
Vendor: IBM
Module: IBMTCPIPMVS-MIB
[Automatically extracted from oidview.com]
ibmMvsAtmOsasfPvcVci OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "vci for this PVC. This value must be greater than or equal to 32 since the first 32 vci code points have been reserved by the ATM Forum." ::= { osasfPvcEntry 10 }
ibmMvsAtmOsasfPvcVci OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "vci for this PVC. This value must be greater than or equal to 32 since the first 32 vci code points have been reserved by the ATM Forum." ::= { osasfPvcEntry 10 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.2.6.19.2.2.6.3.1.1 | ibmMvsAtmOsasfPvcName | 0 | 0 | PVC Name |
1.3.6.1.4.1.2.6.19.2.2.6.3.1.2 | ibmMvsAtmOsasfPvcBestEffort | 0 | 0 | Best Effort rate. 0 indicated that best effort delivery is not desired. 1 indicates that best effort delivery is desired. |
1.3.6.1.4.1.2.6.19.2.2.6.3.1.3 | ibmMvsAtmOsasfPvcFwdPeakCellRate | 0 | 0 | Forward peak cell rate specified as cells per second. Needed in order to set up either a best effort or a reserved bandwidth PVC.… |
1.3.6.1.4.1.2.6.19.2.2.6.3.1.4 | ibmMvsAtmOsasfPvcBwdPeakCellRate | 0 | 0 | Backward peak cell rate specified as cells per second. Needed in order to set up either a best effort or a reserved bandwidth PVC… |
1.3.6.1.4.1.2.6.19.2.2.6.3.1.5 | ibmMvsAtmOsasfPvcFwdsustainCellRate | 0 | 0 | Forward sustain cell rate specified as cells per second. If the best effort indicator is on, the value of this object is ignored.… |
1.3.6.1.4.1.2.6.19.2.2.6.3.1.6 | ibmMvsAtmOsasfPvcBwdsustainCellRate | 0 | 0 | Backward sustain cell rate specified as cells per second. If the best effort indicator is on, the value of this object is ignored… |
1.3.6.1.4.1.2.6.19.2.2.6.3.1.7 | ibmMvsAtmOsasfPvcFwdCellBurstSize | 0 | 0 | Forward cell burst size specified as number of cells. If the best effort indicator is on, the value of this object is ignored. Ot… |
1.3.6.1.4.1.2.6.19.2.2.6.3.1.8 | ibmMvsAtmOsasfPvcBwdCellBurstSize | 0 | 0 | Backward cell burst size specified as number of cells. If the best effort indicator is on, the value of this object is ignored. O… |
1.3.6.1.4.1.2.6.19.2.2.6.3.1.9 | ibmMvsAtmOsasfPvcVpi | 0 | 0 | vpi for this PVC |
1.3.6.1.4.1.2.6.19.2.2.6.3.1.11 | ibmMvsAtmOsasfPvcFwdMaxAal5PduSize | 0 | 0 | This field is used to setup the PVC. Units are in OCTETs and represents the largest PDU size for the AAL5 CPCS layer that can be … |
1.3.6.1.4.1.2.6.19.2.2.6.3.1.12 | ibmMvsAtmOsasfPvcBwdMaxAal5PduSize | 0 | 0 | This field is used to setup the PVC. Units are in OCTETs and represents the largest PDU size for the AAL5 CPCS layer that can be … |