Timer_KEEP-ALIVE as defined in the Q.2110 Specification.
This timer is started when entering the transient phase.
Parsed from file atmmib21.mib.txt
Company: ibm
Module: ATM-SWITCHING-NODE-MIB
Vendor: IBM
Module: ATM-SWITCHING-NODE-MIB
[Automatically extracted from oidview.com]
atmSaalTimerKeepAlive OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Timer_KEEP-ALIVE as defined in the Q.2110 Specification. This timer is started when entering the transient phase." ::= { atmSaalConfEntry 6 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.2.6.33.1.9.2.1.1.1 | atmSaalConfIndex | 0 | 0 | The ifIndex value of the ATM interface which, with the signalling channel defined by its Vpi/Vci values, uniquely identifies this… |
1.3.6.1.4.1.2.6.33.1.9.2.1.1.2 | atmSaalConfSiVpi | 0 | 0 | The Vpi value which, with the Vci value specified in atmSaalConfSiVci, defines the signalling channel for this entry. Usually, the… |
1.3.6.1.4.1.2.6.33.1.9.2.1.1.3 | atmSaalConfSiVci | 0 | 0 | The Vci value which, with the Vpi value specified in atmSaalConfSiVpi, defines the signalling channel for this entry. Usually, the… |
1.3.6.1.4.1.2.6.33.1.9.2.1.1.4 | atmSaalState | 0 | 0 | The state of the SAAL for this interface as defined in the Q.2110 Specification, Chapter 7.3. |
1.3.6.1.4.1.2.6.33.1.9.2.1.1.5 | atmSaalTimerPoll | 0 | 0 | Timer_POLL as defined in the Q.2110 Specification. This timer is running in the active phase to assure that the peer receiver is … |
1.3.6.1.4.1.2.6.33.1.9.2.1.1.7 | atmSaalTimerNoResponse | 0 | 0 | Timer_NO-RESPONSE as defined in the Q.2110 Specification. This timer indicates the maximum time interval during which at least on… |
1.3.6.1.4.1.2.6.33.1.9.2.1.1.8 | atmSaalTimerCC | 0 | 0 | Timer_CC as defined in the Q.2110 Specification. Transmission of PDUs is protected by this timer during establishment and release… |
1.3.6.1.4.1.2.6.33.1.9.2.1.1.9 | atmSaalTimerIdle | 0 | 0 | Timer_IDLE as defined in the Q.2110 Specification. This timer is started upon receipt of a STAT PDU when entering the idle phase … |
1.3.6.1.4.1.2.6.33.1.9.2.1.1.10 | atmSaalMaxCC | 0 | 0 | MaxCC as defined in the Q.2110 Specification. This is the maximum value for the state variable VT(CC), corresponding to the maxim… |
1.3.6.1.4.1.2.6.33.1.9.2.1.1.11 | atmSaalMaxPD | 0 | 0 | MaxPD as defined in the Q.2110 Specification. This is the maximum iacceptable value for the state variable VT(PD) before sending … |
1.3.6.1.4.1.2.6.33.1.9.2.1.1.12 | atmSaalMaxStat | 0 | 0 | MaxSTAT as defined in the Q.2110 Specification. This is the maximum number of list elements placed in a STAT PDU. |