A change in the value of certain MIB objects could be service affecting. Henceforth,
such objects are called restricted objects. The object umc1RestrictedAccess is
used to control a SET operation on the restricted objects. A SET to the
umc1RestrictedAccess object (set to enable) must precede a SET to restricted objects
in the same PDU. Further, a SET to the umc1RestrictedAccess object (set
to disable) must follow a SET to restricted objects in the same PDU.
A GET operation to read its value shall always return the value disable.
Parsed from file umc1000.mib.txt
Company: None
Module: UMC1000-MIB
A change in the value of certain MIB objects could be service affecting. Henceforth,
such objects are called restricted objects. The object umc1RestrictedAccess is
used to control a SET operation on the restricted objects. A SET to the
umc1RestrictedAccess object (set to enable) must precede a SET to restricted objects
in the same PDU. Further, a SET to the umc1RestrictedAccess object (set
to disable) must follow a SET to restricted objects in the same PDU.
A GET operation to read its value shall always return the value disable.
Parsed from file UMC1000-MIB.mib
Module: UMC1000-MIB
Child arc 0 is used to translate between SNMPv1 and SNMPv2 notification parameters as explained in IETF RFC 2576, section 3.
umc1RestrictedAccess OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "A change in the value of certain MIB objects could be service affecting. Henceforth, such objects are called restricted objects. The object umc1RestrictedAccess is used to control a SET operation on the restricted objects. A SET to the umc1RestrictedAccess object (set to enable) must precede a SET to restricted objects in the same PDU. Further, a SET to the umc1RestrictedAccess object (set to disable) must follow a SET to restricted objects in the same PDU. A GET operation to read its value shall always return the value disable." ::= { umc1System 6 }
umc1RestrictedAccess OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "A change in the value of certain MIB objects could be service affecting. Henceforth, such objects are called restricted objects. The object umc1RestrictedAccess is used to control a SET operation on the restricted objects. A SET to the umc1RestrictedAccess object (set to enable) must precede a SET to restricted objects in the same PDU. Further, a SET to the umc1RestrictedAccess object (set to disable) must follow a SET to restricted objects in the same PDU. A GET operation to read its value shall always return the value disable." ::= { umc1System 6 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.2067.1.1.2.1.6.0 | umc1RestrictedAccess | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.2067.1.1.2.1.1 | umc1SystemDateTime | 1 | 1 | The system date and time is accessible as follows: octet[0] Timezone (0 through 24) octet[1] High-order 8-bits (MSB) of Year o… |
1.3.6.1.4.1.2067.1.1.2.1.2 | umc1SystemSysProv | 11 | 30 | None |
1.3.6.1.4.1.2067.1.1.2.1.3 | umc1SystemPitProv | 10 | 48 | None |
1.3.6.1.4.1.2067.1.1.2.1.4 | umc1CpuSoftwareFeatures | 1 | 1 | This object lists the features built into the UMC system. The list information required by the IPMI and EMS to determine the type… |
1.3.6.1.4.1.2067.1.1.2.1.5 | umc1SystemRelearnTrapSeqNum | 1 | 1 | A sequence number used to indicate the number of times the ACO operation has been performed since the agent last restarted. When… |
1.3.6.1.4.1.2067.1.1.2.1.7 | umc1Service | 6 | 33 | None |
1.3.6.1.4.1.2067.1.1.2.1.8 | umc1XConnect | 3 | 10 | None |
1.3.6.1.4.1.2067.1.1.2.1.9 | umc1SystemAllSeqNbr | 1 | 1 | This object encapsulates all sequence numbers. The format of this object is: Octet[0] contains version, 0x01 for this relea… |
1.3.6.1.4.1.2067.1.1.2.1.10 | umc1AtmProtTableChangeSeqNum | 1 | 1 | A sequence number used to indicate that the ATM Protection group provisioning Table, umc1AtmProtGrpTable, has been modified and … |
1.3.6.1.4.1.2067.1.1.2.1.11 | umc1AtmProtGrpTable | 1 | 3 | A Management Station uses this table to read, modify, create or delete a ATM Protection Group in the UMC system. The MIB Table h… |
1.3.6.1.4.1.2067.1.1.2.1.12 | umc1AtmProtGrpChgTable | 1 | 3 | The EMS uses this table to synchronize its internal representation of the ATM Protection Group Provisioning data with that manag… |
1.3.6.1.4.1.2067.1.1.2.1.13 | umc1PortProfTableChangeSeqNum | 1 | 1 | umc1PortProftableChangeSeqNum |
1.3.6.1.4.1.2067.1.1.2.1.14 | umc1PortProfTable | 1 | 3 | umc1PortProftable |
1.3.6.1.4.1.2067.1.1.2.1.15 | umc1PortProfChgTable | 1 | 3 | The EMS uses this table to synchronize its internal representation of the Port Profile Provisioning data with that managed by th… |
1.3.6.1.4.1.2067.1.1.2.1.16 | umc1MyAgentSoftwareFeatures | 1 | 1 | This object lists the features built into this load of IPMI software. Octet[0] represents the version of the packed format of … |
1.3.6.1.4.1.2067.1.1.2.1.17 | umc1Security | 3 | 10 | None |
1.3.6.1.4.1.2067.1.1.2.1.18 | umc1SystemGenericDbProv | 3 | 10 | None |
1.3.6.1.4.1.2067.1.1.2.1.19 | umc1MibVersion | 1 | 1 | This object gives Version of MIB supported by this load of IPMI software. Octet[0] represents the version of the packed format… |
1.3.6.1.4.1.2067.1.1.2.1.20 | umc1DbRecordChangeTrapHandleMask | 1 | 1 | This object describes how Db Record Change Trap for a given Db Record Type is being handle by IPMI. For the Db Record Type liste… |
1.3.6.1.4.1.2067.1.1.2.1.21 | umc1SystemAutonomousEvent | 2 | 6 | None |