This object will determine the rate at which ICMP ping will be sent out
by the unit to ensure the IP Address remains in the ARP cache of
the unit's default gateway. This object is only useful if
nw2IPAutoDiscoveryState is set to -discover-. DURABLE
Parsed from file Compaq-Nws2000.mib.txt
Company: compaq
Module: NetWorth-Series-2000-MIB
Child arc 0 is used to translate between SNMPv1 and SNMPv2 notification parameters as explained in IETF RFC 2576, section 3.
nw2PingPacketRate OBJECT-TYPE SYNTAX INTEGER (55..65535) ACCESS read-write STATUS mandatory DESCRIPTION "This object will determine the rate at which ICMP ping will be sent out by the unit to ensure the IP Address remains in the ARP cache of the unit's default gateway. This object is only useful if nw2IPAutoDiscoveryState is set to -discover-. DURABLE" ::= { nw2NmmInfo 13 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.215.1.1.6.1.13.0 | nw2PingPacketRate | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.215.1.1.6.1.1 | nw2ModuleDescr | 1 | 1 | Text description of module. Includes firmware revision level. |
1.3.6.1.4.1.215.1.1.6.1.2 | nw2HwVer | 1 | 1 | The hardware version level. |
1.3.6.1.4.1.215.1.1.6.1.3 | nw2FwMajorVer | 1 | 1 | The major number of the firmware version. For example, if the firmware version is 2.12, the value of this object would be 2. |
1.3.6.1.4.1.215.1.1.6.1.4 | nw2FwMinorVer | 1 | 1 | The minor number of the firmware version. For example, if the firmware version is 2.12, the value of this object would be 12. |
1.3.6.1.4.1.215.1.1.6.1.5 | nw2ThisNmm | 1 | 1 | The stack index of the SNMP agent controlling this MIB. This corresponds to an entry in nw2StackTable. The topmost module in the… |
1.3.6.1.4.1.215.1.1.6.1.6 | nw2WriteCommunity | 1 | 1 | The write community name FOR ALL MODULES IN THE STACK. If the value is not public, the write community name is not returned for … |
1.3.6.1.4.1.215.1.1.6.1.7 | nw2WriteProtected | 1 | 1 | When set to readonly(2), the entire MIB, with the exception of this object is made read only. This may be used in conjunction wi… |
1.3.6.1.4.1.215.1.1.6.1.8 | nw2BootpRarpRequests | 1 | 1 | If the hub does not have an IP address assignment it periodically attempts to find one via the BOOTP and RARP protocols. Settin… |
1.3.6.1.4.1.215.1.1.6.1.9 | nw2IPFrameType | 1 | 1 | Except when the hub is booting up, it will communicate over IP using a single frame type defining the type of network that the I… |
1.3.6.1.4.1.215.1.1.6.1.10 | nw2IPXFrameType | 1 | 1 | The agent uses the frame to send SAP broadcasts, RIP requests, and IPX Traps. The default is ieee80222(3). |
1.3.6.1.4.1.215.1.1.6.1.11 | nw2IPXSAPBroadcast | 1 | 1 | The hub will generate SAP broadcasts over IPX. This allows the hub to be auto-discovered by NMS, Novell Management System and i… |
1.3.6.1.4.1.215.1.1.6.1.12 | nw2IPAutoDiscoveryState | 1 | 1 | This object will allow a user to enable the unit to send out periodic ICMP echo/request's to ensure that the unit's IP Address i… |
1.3.6.1.4.1.215.1.1.6.1.14 | nw2NVRAMStatus | 1 | 1 | This object provides status information of the non-volatile memory for the unit. If the value is error(2), all status infomatio… |
1.3.6.1.4.1.215.1.1.6.1.15 | nw2rptrReset | 1 | 1 | Setting this object to reset(2) causes the unit to restart, as if the unit was powered off then back on. All counters are destr… |