uemSwitchtable
View at oid-info.com
An entry for each switch in the monitored system.
Switches report true/false status and are useful for indicating
open doors, unlocked keys, etc. There may be zero or more rows in this table.
One column, uemSwitchContext, is a displayable string that reports
the meaning of the current true/false state of the switch such as
'Open', 'Closed', 'Locked', 'Unlocked' etc. Other columns allow access to the
actual true/false state and which state is expected in a properly
operating system.
Parsed from file VisiNet2_mib.txt
Company: None
Module: VISINET2-MIB
An entry for each switch in the monitored system.
Switches report true/false status and are useful for indicating
open doors, unlocked keys, etc. There may be zero or more rows in this table.
One column, uemSwitchContext, is a displayable string that reports
the meaning of the current true/false state of the switch such as
'Open', 'Closed', 'Locked', 'Unlocked' etc. Other columns allow access to the
actual true/false state and which state is expected in a properly
operating system.
Parsed from file VISINET2-MIB.mib
Module: VISINET2-MIB
Vendor: Unisys_Corp
Module: VISINET2-MIB
[Automatically extracted from oidview.com]
uemSwitchTable OBJECT-TYPE SYNTAX SEQUENCE OF UemSwitchTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry for each switch in the monitored system. Switches report true/false status and are useful for indicating open doors, unlocked keys, etc. There may be zero or more rows in this table. One column, uemSwitchContext, is a displayable string that reports the meaning of the current true/false state of the switch such as 'Open', 'Closed', 'Locked', 'Unlocked' etc. Other columns allow access to the actual true/false state and which state is expected in a properly operating system." ::= { unisysEnvMonitor 18 }
uemSwitchTable OBJECT-TYPE SYNTAX SEQUENCE OF UemSwitchTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry for each switch in the monitored system. Switches report true/false status and are useful for indicating open doors, unlocked keys, etc. There may be zero or more rows in this table. One column, uemSwitchContext, is a displayable string that reports the meaning of the current true/false state of the switch such as 'Open', 'Closed', 'Locked', 'Unlocked' etc. Other columns allow access to the actual true/false state and which state is expected in a properly operating system." ::= { unisysEnvMonitor 18 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.223.10.6.18.1 | uemSwitchTableEntry | 7 | 7 | uemSwitchtableEntry |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.223.10.6.1 | uemTrapConfigurationChange | 0 | 0 | None |
1.3.6.1.4.1.223.10.6.2 | uemAgentRevMajor | 1 | 1 | Major version of the Unisys Environmental Monitoring Agent. |
1.3.6.1.4.1.223.10.6.3 | uemTrapSensorWarning, uemAgentRevMinor | 1 | 1 | Minor version of the Unisys Environmental Monitoring Agent. |
1.3.6.1.4.1.223.10.6.4 | uemMibRevMajor | 1 | 1 | The Major Revision level of this MIB. A change in the major revision level represents a possible compatibility problem with older… |
1.3.6.1.4.1.223.10.6.5 | uemTrapSwitchAlert, uemMibRevMinor | 1 | 1 | The minor revision level of this MIB. A change in the minor revision level may represent some minor additional support, changes… |
1.3.6.1.4.1.223.10.6.6 | uemTrapSwitchNormal | 0 | 0 | None |
1.3.6.1.4.1.223.10.6.7 | uemSystemDescription | 1 | 1 | Text describing this system such as manufacturer and model number. |
1.3.6.1.4.1.223.10.6.8 | uemTrapsEnabled | 1 | 1 | All Environmental Monitoring traps can be globally disabled by setting this FALSE. |
1.3.6.1.4.1.223.10.6.9 | uemTrapSeverity | 1 | 1 | Additional information delivered with sensor and switch trap messages. Advanced management applications can make use of this inf… |
1.3.6.1.4.1.223.10.6.16 | uemEnvMonitorTable | 1 | 8 | An entry for each Monitor device on this host that is actively reporting environmental data via the SNMP Agent. There may ofen on… |
1.3.6.1.4.1.223.10.6.17 | uemSensorTable | 1 | 17 | All fan, temperature and voltage sensors are collected in this table. All these devices are similar in that they monitor 5 value… |