Reference record for OID 1.3.6.1.4.1.223.10.6.17


parent
1.3.6.1.4.1.223.10.6 (unisysEnvMonitor)
node code
17
node name
uemSensorTable
dot oid
1.3.6.1.4.1.223.10.6.17
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) unisys(223) unisysOpen(10) unisysEnvMonitor(6) uemSensorTable(17)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) unisys(223) unisysOpen(10) unisysEnvMonitor(6) uemSensorTable(17)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) unisys(223) unisysOpen(10) unisysEnvMonitor(6) uemSensorTable(17)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) unisys(223) unisysOpen(10) unisysEnvMonitor(6) uemSensorTable(17)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) unisys(223) unisysOpen(10) unisysEnvMonitor(6) uemSensorTable(17)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) unisys(223) unisysOpen(10) unisysEnvMonitor(6) uemSensorTable(17)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/unisys/unisysOpen/unisysEnvMonitor/uemSensorTable
  • /iso/identified-organization/dod/internet/private/enterprises/unisys/unisysOpen/unisysEnvMonitor/uemSensorTable
  • /iso/org/dod/internet/private/enterprise/unisys/unisysOpen/unisysEnvMonitor/uemSensorTable
  • /iso/org/dod/internet/private/enterprises/unisys/unisysOpen/unisysEnvMonitor/uemSensorTable
  • /iso/iso-identified-organization/dod/internet/private/enterprise/unisys/unisysOpen/unisysEnvMonitor/uemSensorTable
  • /iso/iso-identified-organization/dod/internet/private/enterprises/unisys/unisysOpen/unisysEnvMonitor/uemSensorTable
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/223/10/6/17

    Description by mibdepot

    All fan, temperature and voltage sensors are collected in this table.
    All these devices are similar in that they monitor 5 value ranges:
    low critical, low warning, normal, high warning, high critical.
    Notifications (trap messages) are sent whenever the monitored value moves
    from one value range to another. The guard points defining the 5 monitored
    regions (or range of values) are read-write allowing remote configuration
    by an SNMP management console.

    There may be zero or more rows in this table. Each row in the table contains
    information about a single sensor. One column, uemSensorType, identifies
    the type of sensor as fan, temp or voltage. Another column, uemSensorStatus,
    identifies where in the 5 possible ranges the monitored device is currently
    operating within. Each row is linked to a parent EnvMonitor row to further
    identify its location within the server.

    Parsed from file VisiNet2_mib.txt
    Company: None
    Module: VISINET2-MIB

    Description by circitor

    All fan, temperature and voltage sensors are collected in this table.
    All these devices are similar in that they monitor 5 value ranges:
    low critical, low warning, normal, high warning, high critical.
    Notifications (trap messages) are sent whenever the monitored value moves
    from one value range to another. The guard points defining the 5 monitored
    regions (or range of values) are read-write allowing remote configuration
    by an SNMP management console.

    There may be zero or more rows in this table. Each row in the table contains
    information about a single sensor. One column, uemSensorType, identifies
    the type of sensor as fan, temp or voltage. Another column, uemSensorStatus,
    identifies where in the 5 possible ranges the monitored device is currently
    operating within. Each row is linked to a parent EnvMonitor row to further
    identify its location within the server.

    Parsed from file VISINET2-MIB.mib
    Module: VISINET2-MIB

    Information by oid_info

    Vendor: Unisys_Corp
    Module: VISINET2-MIB

    [Automatically extracted from oidview.com]

    Information by mibdepot

    uemSensorTable OBJECT-TYPE SYNTAX SEQUENCE OF UemSensorTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "All fan, temperature and voltage sensors are collected in this table. All these devices are similar in that they monitor 5 value ranges: low critical, low warning, normal, high warning, high critical. Notifications (trap messages) are sent whenever the monitored value moves from one value range to another. The guard points defining the 5 monitored regions (or range of values) are read-write allowing remote configuration by an SNMP management console. There may be zero or more rows in this table. Each row in the table contains information about a single sensor. One column, uemSensorType, identifies the type of sensor as fan, temp or voltage. Another column, uemSensorStatus, identifies where in the 5 possible ranges the monitored device is currently operating within. Each row is linked to a parent EnvMonitor row to further identify its location within the server." ::= { unisysEnvMonitor 17 }

    Information by circitor

    uemSensorTable OBJECT-TYPE SYNTAX SEQUENCE OF UemSensorTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "All fan, temperature and voltage sensors are collected in this table. All these devices are similar in that they monitor 5 value ranges: low critical, low warning, normal, high warning, high critical. Notifications (trap messages) are sent whenever the monitored value moves from one value range to another. The guard points defining the 5 monitored regions (or range of values) are read-write allowing remote configuration by an SNMP management console. There may be zero or more rows in this table. Each row in the table contains information about a single sensor. One column, uemSensorType, identifies the type of sensor as fan, temp or voltage. Another column, uemSensorStatus, identifies where in the 5 possible ranges the monitored device is currently operating within. Each row is linked to a parent EnvMonitor row to further identify its location within the server." ::= { unisysEnvMonitor 17 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.223)

    Brow Lawrence

    Children (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.223.10.6.17.1 uemSensorTableEntry 16 16 None

    Brothers (11)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.223.10.6.1 uemTrapConfigurationChange 0 0 None
    1.3.6.1.4.1.223.10.6.2 uemAgentRevMajor 1 1 Major version of the Unisys Environmental Monitoring Agent.
    1.3.6.1.4.1.223.10.6.3 uemTrapSensorWarning, uemAgentRevMinor 1 1 Minor version of the Unisys Environmental Monitoring Agent.
    1.3.6.1.4.1.223.10.6.4 uemMibRevMajor 1 1 The Major Revision level of this MIB.
    A change in the major revision level represents a possible
    compatibility problem with older…
    1.3.6.1.4.1.223.10.6.5 uemTrapSwitchAlert, uemMibRevMinor 1 1 The minor revision level of this MIB. A change in the
    minor revision level may represent some minor additional
    support, changes…
    1.3.6.1.4.1.223.10.6.6 uemTrapSwitchNormal 0 0 None
    1.3.6.1.4.1.223.10.6.7 uemSystemDescription 1 1 Text describing this system such as manufacturer and model number.
    1.3.6.1.4.1.223.10.6.8 uemTrapsEnabled 1 1 All Environmental Monitoring traps can be globally disabled
    by setting this FALSE.
    1.3.6.1.4.1.223.10.6.9 uemTrapSeverity 1 1 Additional information delivered with sensor and switch trap messages.
    Advanced management applications can make use of this inf…
    1.3.6.1.4.1.223.10.6.16 uemEnvMonitorTable 1 8 An entry for each Monitor device on this host that is
    actively reporting environmental data via the SNMP Agent.
    There may ofen on…
    1.3.6.1.4.1.223.10.6.18 uemSwitchTable 1 8 uemSwitchtable