Used to enable/disable the Explicit Congestion
Notification(ECN) compatibility feature.
When set to FALSE , the system will mask the ECN bits
in the DS field while re-marking DSCP and will not match
on ECN capable flows if filter is set on DSmatch.
When set to TRUE, it will preserve the ECN bits in the DS
field while re-marking and will match on full 8-bit DS field.
Parsed from file rapid_city-accelar.mib.txt
Company: None
Module: RAPID-CITY
Used to enable/disable the Explicit Congestion
Notification(ECN) compatibility feature.
When set to FALSE , the system will mask the ECN bits
in the DS field while re-marking DSCP and will not match
on ECN capable flows if filter is set on DSmatch.
When set to TRUE, it will preserve the ECN bits in the DS
field while re-marking and will match on full 8-bit DS field.
Parsed from file RAPID-CITY.mib
Module: RAPID-CITY
rcChasDiffServEcnCompatibilityEnable OBJECT-TYPE SYNTAX TruthValue ACCESS read-write STATUS mandatory DESCRIPTION "Used to enable/disable the Explicit Congestion Notification(ECN) compatibility feature. When set to FALSE , the system will mask the ECN bits in the DS field while re-marking DSCP and will not match on ECN capable flows if filter is set on DSmatch. When set to TRUE, it will preserve the ECN bits in the DS field while re-marking and will match on full 8-bit DS field." DEFVAL { false } ::= { rcChassis 20 }
Vendor: Rapid City Communication
Module: RAPID-CITY
[Automatically extracted from oidview.com]
rcChasDiffServEcnCompatibilityEnable OBJECT-TYPE SYNTAX TruthValue ACCESS read-write STATUS mandatory DESCRIPTION "Used to enable/disable the Explicit Congestion Notification(ECN) compatibility feature. When set to FALSE , the system will mask the ECN bits in the DS field while re-marking DSCP and will not match on ECN capable flows if filter is set on DSmatch. When set to TRUE, it will preserve the ECN bits in the DS field while re-marking and will match on full 8-bit DS field." DEFVAL { false } ::= { rcChassis 20 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.2272.1.4.20.0 | rcChasDiffServEcnCompatibilityEnable | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.2272.1.4.1 | rcChasType | 1 | 1 | Chassis Type |
1.3.6.1.4.1.2272.1.4.2 | rcChasSerialNumber | 1 | 1 | Unique serial number for this chassis. |
1.3.6.1.4.1.2272.1.4.3 | rcChasHardwareRevision | 1 | 1 | Device hardware revision level |
1.3.6.1.4.1.2272.1.4.4 | rcChasNumSlots | 1 | 1 | The number of slots in the chassis available for plug-in cards. |
1.3.6.1.4.1.2272.1.4.5 | rcChasNumPorts | 1 | 1 | The total number of ports currently installed in the chassis. |
1.3.6.1.4.1.2272.1.4.6 | rcChasTestResult | 1 | 1 | Chassis start-up diagnostic tests. |
1.3.6.1.4.1.2272.1.4.7 | rcChasFan | 1 | 6 | None |
1.3.6.1.4.1.2272.1.4.8 | rcChasPowerSupply | 2 | 15 | None |
1.3.6.1.4.1.2272.1.4.9 | rcCard | 1 | 10 | None |
1.3.6.1.4.1.2272.1.4.10 | rcPort | 11 | 196 | None |
1.3.6.1.4.1.2272.1.4.11 | rcPortLock | 2 | 4 | None |
1.3.6.1.4.1.2272.1.4.12 | rcChasAruMode | 1 | 1 | The ARU mode the chassis is operating in. |
1.3.6.1.4.1.2272.1.4.13 | rcChasQuidMode | 1 | 1 | The Quid mode the chassis is operating in. |
1.3.6.1.4.1.2272.1.4.14 | rcChasEocModeAdminStatus | 1 | 1 | Used to specify the Enforce Operational Configuration Mode(EOC) of the system. When a device is configured with hardware of diff… |
1.3.6.1.4.1.2272.1.4.15 | rcChasEocModeOperStatus | 1 | 1 | Used to indicate the Enforce Operational Configuration Mode(EOC) of the system. |
1.3.6.1.4.1.2272.1.4.16 | rcAgentTable | 1 | 4 | Agents in a chassis table |
1.3.6.1.4.1.2272.1.4.17 | rcChasBrouterPorts | 1 | 1 | Used to indicate which ports in the system are configured as Brouter ports. |
1.3.6.1.4.1.2272.1.4.18 | rcChasGlobalFilterEnable | 1 | 1 | Used to enable/disable global filters in the system. This variable is currently not supported. |
1.3.6.1.4.1.2272.1.4.19 | rcChasVlanBySrcMacEnable | 1 | 1 | Used to enable/disable source MAC based VLANs in the system. |
1.3.6.1.4.1.2272.1.4.21 | rcChasNewEnhancedOperMode | 1 | 1 | Enhanced operational mode. |
1.3.6.1.4.1.2272.1.4.22 | rcChasNewEMMode | 1 | 1 | This configuration is for enabling/disabling 128K mode. The change will take effect upon reboot. |
1.3.6.1.4.1.2272.1.4.23 | rcChasEmModeError | 1 | 1 | Used to indicate the Em-mode error status |
1.3.6.1.4.1.2272.1.4.24 | rcChasEnhancedOperMode | 1 | 1 | Enhanced Operational mode the switch currently has booted and will remain the same unitl the next reboot. |
1.3.6.1.4.1.2272.1.4.25 | rcChasEMMode | 1 | 1 | EM mode the switch currently has booted and will remain the same unitl the next reboot. |
1.3.6.1.4.1.2272.1.4.26 | rcChasFtpDaemonInSecondaryCpu | 1 | 1 | Used to enable/disable FTP daemon in 2nd cpu. |
1.3.6.1.4.1.2272.1.4.27 | rcChasSmltOnSingleCpEnable | 1 | 1 | Enable SMLT on single CP feature in the switch |
1.3.6.1.4.1.2272.1.4.28 | rcChasNewVlanOptmMode | 1 | 1 | Vlan Optimization mode. |
1.3.6.1.4.1.2272.1.4.29 | rcChasVlanOptmMode | 1 | 1 | Vlan Optimization mode the switch currently has booted and will remain the same unitl the next reboot. |
1.3.6.1.4.1.2272.1.4.30 | rcLaunchPad | 0 | 0 | None |
1.3.6.1.4.1.2272.1.4.31 | rcChasNaapEnable | 1 | 1 | To enable/disbale to napp feature. |
1.3.6.1.4.1.2272.1.4.32 | rcChasGlobalFilterOrderingEnable | 1 | 1 | Used to enable/disable global filter ordering in the system. |
1.3.6.1.4.1.2272.1.4.33 | rcChasNewGlobalFilterOrderingEnable | 1 | 1 | This configuration is for enabling/disabling global filter ordering. The change will take effect upon reboot. |
1.3.6.1.4.1.2272.1.4.34 | rcChasWsmDirectMode | 1 | 1 | This is for enabling/disabling configuration of same community strings on the WSM and 8600. This if for allowing users to connec… |
1.3.6.1.4.1.2272.1.4.35 | rcChasRspMode | 1 | 1 | This configuration is for enabling/disabling 256K mode. The change will take effect upon reboot. |
1.3.6.1.4.1.2272.1.4.36 | rcChasRspOperMode | 1 | 1 | R-mode the switch currently has booted and will remain the same until the next reboot. |
1.3.6.1.4.1.2272.1.4.37 | rcChasRspModeError | 1 | 1 | Used to indicate the r-mode error status |
1.3.6.1.4.1.2272.1.4.38 | rcChasPOE | 4 | 8 | None |
1.3.6.1.4.1.2272.1.4.39 | rcRepeater | 1 | 8 | None |
1.3.6.1.4.1.2272.1.4.40 | rcAtmPortLecExt, rcChasMcastCheckPktEnable | 2 | 12 | Used to enable/disable Multicast check packet in the system. This change will take effect upon reboot. |
1.3.6.1.4.1.2272.1.4.41 | rcChasSystemMonitorEnable | 1 | 1 | Enable/Disable System monitoring in the switch |
1.3.6.1.4.1.2272.1.4.42 | rcChasSysMonMonitoringEnable | 1 | 1 | Dyanamically Enable/Disable SystemMonitor monitoring engine in the switch |
1.3.6.1.4.1.2272.1.4.43 | rcChasSysMonDetectionTime | 1 | 1 | System Monitor Detection time in seconds |
1.3.6.1.4.1.2272.1.4.44 | rcChasNewMulticastResourceReservation | 1 | 1 | Used to reserve MGIDs for IP Multicast. The change will take effect upon reboot. |
1.3.6.1.4.1.2272.1.4.45 | rcChasMulticastResourceReservation | 1 | 1 | MGIDs the switch currently has reserved for IP Multicast; will remain the same until the next reboot. |
1.3.6.1.4.1.2272.1.4.46 | rcChasNewMaxVlanResourceReservation | 1 | 1 | A mode where all MGIDs are reserved for VLAN use only; no IPMC. The change will take effect upon reboot. |
1.3.6.1.4.1.2272.1.4.47 | rcChasMaxVlanResourceReservation | 1 | 1 | Tells if all MGIDs are reserved for VLAN use. Will remain the same until the next reboot. |
1.3.6.1.4.1.2272.1.4.48 | rcChasMgidUsageVlanCurrent | 1 | 1 | Number of MGIDs currently used for VLAN, including SMLT |
1.3.6.1.4.1.2272.1.4.49 | rcChasMgidUsageVlanRemaining | 1 | 1 | Number of MGIDs remaining allocated for VLAN |
1.3.6.1.4.1.2272.1.4.50 | rcChasMgidUsageMulticastCurrent | 1 | 1 | Number of MGIDs currently used for IPMC |
1.3.6.1.4.1.2272.1.4.51 | rcChasMgidUsageMulticastRemaining | 1 | 1 | Number of MGIDs remaining allocated for IPMC |
1.3.6.1.4.1.2272.1.4.52 | rcChasPowerManagementEnable | 1 | 1 | Turn on or off Chassis Power Management. The configuration will take effect upon reboot |
1.3.6.1.4.1.2272.1.4.53 | rcChasForceTopologyIpFlagEnable | 1 | 1 | Used to enable/disable flag which is used to set the CLIP-ip as topology ip |
1.3.6.1.4.1.2272.1.4.54 | rcChasCircuitlessIpId | 1 | 1 | The Clip-Id set by the user to be used as Topology-ip |
1.3.6.1.4.1.2272.1.4.55 | rcChasPowerManagementOriginalEnable | 1 | 1 | On or off value of Chassis Power Management which the switch has currently booted. It will remain the same until the next reboot. |
1.3.6.1.4.1.2272.1.4.56 | rcChasPowerManagementFanCheck | 1 | 1 | Turn on or off the Fan Check functionility of Chassis Power Management. The value takes effect only on reboot. |
1.3.6.1.4.1.2272.1.4.57 | rcChasPowerManagementFanCheckOriginalState | 1 | 1 | The on or off value of fan check which the switch has booted with. The value does not take effect till the next reboot. |
1.3.6.1.4.1.2272.1.4.58 | rcChasEsmHashIndex | 1 | 1 | This is for enabling/disabling hashing on the upper 24 bits of the UNI for ESM card |
1.3.6.1.4.1.2272.1.4.59 | rcChasSwitchFabricRedundancy | 1 | 1 | Turn on or off 2:1 Redundancy for 8011co Chassis |