Enhanced Operational mode the switch currently has
booted and will remain the same unitl the next reboot.
Parsed from file rapid_city-accelar.mib.txt
Company: rapidcity
Module: RAPID-CITY
rcChasEnhancedOperMode OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Enhanced Operational mode the switch currently has booted and will remain the same unitl the next reboot." ::= { rcChassis 24 }
Vendor: Rapid City Communication
Module: RAPID-CITY
[Automatically extracted from oidview.com]
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.2272.1.4.24.0 | rcChasEnhancedOperMode | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.2272.1.4.1 | rcChasType | 1 | 1 | Chassis Type |
1.3.6.1.4.1.2272.1.4.2 | rcChasSerialNumber | 1 | 1 | Unique serial number for this chassis. |
1.3.6.1.4.1.2272.1.4.3 | rcChasHardwareRevision | 1 | 1 | Device hardware revision level |
1.3.6.1.4.1.2272.1.4.4 | rcChasNumSlots | 1 | 1 | The number of slots in the chassis available for plug-in cards. |
1.3.6.1.4.1.2272.1.4.5 | rcChasNumPorts | 1 | 1 | The total number of ports currently installed in the chassis. |
1.3.6.1.4.1.2272.1.4.6 | rcChasTestResult | 1 | 1 | Chassis start-up diagnostic tests. |
1.3.6.1.4.1.2272.1.4.7 | rcChasFan | 1 | 6 | None |
1.3.6.1.4.1.2272.1.4.8 | rcChasPowerSupply | 2 | 15 | None |
1.3.6.1.4.1.2272.1.4.9 | rcCard | 1 | 10 | None |
1.3.6.1.4.1.2272.1.4.10 | rcPort | 11 | 196 | None |
1.3.6.1.4.1.2272.1.4.11 | rcPortLock | 2 | 4 | None |
1.3.6.1.4.1.2272.1.4.12 | rcChasAruMode | 1 | 1 | The ARU mode the chassis is operating in. |
1.3.6.1.4.1.2272.1.4.13 | rcChasQuidMode | 1 | 1 | The Quid mode the chassis is operating in. |
1.3.6.1.4.1.2272.1.4.14 | rcChasEocModeAdminStatus | 1 | 1 | Used to specify the Enforce Operational Configuration Mode(EOC) of the system. When a device is configured with hardware of diff… |
1.3.6.1.4.1.2272.1.4.15 | rcChasEocModeOperStatus | 1 | 1 | Used to indicate the Enforce Operational Configuration Mode(EOC) of the system. |
1.3.6.1.4.1.2272.1.4.16 | rcAgentTable | 1 | 4 | Agents in a chassis table |
1.3.6.1.4.1.2272.1.4.17 | rcChasBrouterPorts | 1 | 1 | Used to indicate which ports in the system are configured as Brouter ports. |
1.3.6.1.4.1.2272.1.4.18 | rcChasGlobalFilterEnable | 1 | 1 | Used to enable/disable global filters in the system. This variable is currently not supported. |
1.3.6.1.4.1.2272.1.4.19 | rcChasVlanBySrcMacEnable | 1 | 1 | Used to enable/disable source MAC based VLANs in the system. |
1.3.6.1.4.1.2272.1.4.20 | rcChasDiffServEcnCompatibilityEnable | 1 | 1 | Used to enable/disable the Explicit Congestion Notification(ECN) compatibility feature. When set to FALSE , the system will mask … |
1.3.6.1.4.1.2272.1.4.21 | rcChasNewEnhancedOperMode | 1 | 1 | Enhanced operational mode. |
1.3.6.1.4.1.2272.1.4.22 | rcChasNewEMMode | 1 | 1 | This configuration is for enabling/disabling 128K mode. The change will take effect upon reboot. |
1.3.6.1.4.1.2272.1.4.23 | rcChasEmModeError | 1 | 1 | Used to indicate the Em-mode error status |
1.3.6.1.4.1.2272.1.4.25 | rcChasEMMode | 1 | 1 | EM mode the switch currently has booted and will remain the same unitl the next reboot. |
1.3.6.1.4.1.2272.1.4.26 | rcChasFtpDaemonInSecondaryCpu | 1 | 1 | Used to enable/disable FTP daemon in 2nd cpu. |
1.3.6.1.4.1.2272.1.4.27 | rcChasSmltOnSingleCpEnable | 1 | 1 | Enable SMLT on single CP feature in the switch |
1.3.6.1.4.1.2272.1.4.28 | rcChasNewVlanOptmMode | 1 | 1 | Vlan Optimization mode. |
1.3.6.1.4.1.2272.1.4.29 | rcChasVlanOptmMode | 1 | 1 | Vlan Optimization mode the switch currently has booted and will remain the same unitl the next reboot. |
1.3.6.1.4.1.2272.1.4.30 | rcLaunchPad | 0 | 0 | None |
1.3.6.1.4.1.2272.1.4.31 | rcChasNaapEnable | 1 | 1 | To enable/disbale to napp feature. |
1.3.6.1.4.1.2272.1.4.32 | rcChasGlobalFilterOrderingEnable | 1 | 1 | Used to enable/disable global filter ordering in the system. |
1.3.6.1.4.1.2272.1.4.33 | rcChasNewGlobalFilterOrderingEnable | 1 | 1 | This configuration is for enabling/disabling global filter ordering. The change will take effect upon reboot. |
1.3.6.1.4.1.2272.1.4.34 | rcChasWsmDirectMode | 1 | 1 | This is for enabling/disabling configuration of same community strings on the WSM and 8600. This if for allowing users to connec… |
1.3.6.1.4.1.2272.1.4.35 | rcChasRspMode | 1 | 1 | This configuration is for enabling/disabling 256K mode. The change will take effect upon reboot. |
1.3.6.1.4.1.2272.1.4.36 | rcChasRspOperMode | 1 | 1 | R-mode the switch currently has booted and will remain the same until the next reboot. |
1.3.6.1.4.1.2272.1.4.37 | rcChasRspModeError | 1 | 1 | Used to indicate the r-mode error status |
1.3.6.1.4.1.2272.1.4.38 | rcChasPOE | 4 | 8 | None |
1.3.6.1.4.1.2272.1.4.39 | rcRepeater | 1 | 8 | None |
1.3.6.1.4.1.2272.1.4.40 | rcAtmPortLecExt, rcChasMcastCheckPktEnable | 2 | 12 | Used to enable/disable Multicast check packet in the system. This change will take effect upon reboot. |
1.3.6.1.4.1.2272.1.4.41 | rcChasSystemMonitorEnable | 1 | 1 | Enable/Disable System monitoring in the switch |
1.3.6.1.4.1.2272.1.4.42 | rcChasSysMonMonitoringEnable | 1 | 1 | Dyanamically Enable/Disable SystemMonitor monitoring engine in the switch |
1.3.6.1.4.1.2272.1.4.43 | rcChasSysMonDetectionTime | 1 | 1 | System Monitor Detection time in seconds |
1.3.6.1.4.1.2272.1.4.44 | rcChasNewMulticastResourceReservation | 1 | 1 | Used to reserve MGIDs for IP Multicast. The change will take effect upon reboot. |
1.3.6.1.4.1.2272.1.4.45 | rcChasMulticastResourceReservation | 1 | 1 | MGIDs the switch currently has reserved for IP Multicast; will remain the same until the next reboot. |
1.3.6.1.4.1.2272.1.4.46 | rcChasNewMaxVlanResourceReservation | 1 | 1 | A mode where all MGIDs are reserved for VLAN use only; no IPMC. The change will take effect upon reboot. |
1.3.6.1.4.1.2272.1.4.47 | rcChasMaxVlanResourceReservation | 1 | 1 | Tells if all MGIDs are reserved for VLAN use. Will remain the same until the next reboot. |
1.3.6.1.4.1.2272.1.4.48 | rcChasMgidUsageVlanCurrent | 1 | 1 | Number of MGIDs currently used for VLAN, including SMLT |
1.3.6.1.4.1.2272.1.4.49 | rcChasMgidUsageVlanRemaining | 1 | 1 | Number of MGIDs remaining allocated for VLAN |
1.3.6.1.4.1.2272.1.4.50 | rcChasMgidUsageMulticastCurrent | 1 | 1 | Number of MGIDs currently used for IPMC |
1.3.6.1.4.1.2272.1.4.51 | rcChasMgidUsageMulticastRemaining | 1 | 1 | Number of MGIDs remaining allocated for IPMC |
1.3.6.1.4.1.2272.1.4.52 | rcChasPowerManagementEnable | 1 | 1 | Turn on or off Chassis Power Management. The configuration will take effect upon reboot |
1.3.6.1.4.1.2272.1.4.53 | rcChasForceTopologyIpFlagEnable | 1 | 1 | Used to enable/disable flag which is used to set the CLIP-ip as topology ip |
1.3.6.1.4.1.2272.1.4.54 | rcChasCircuitlessIpId | 1 | 1 | The Clip-Id set by the user to be used as Topology-ip |
1.3.6.1.4.1.2272.1.4.55 | rcChasPowerManagementOriginalEnable | 1 | 1 | On or off value of Chassis Power Management which the switch has currently booted. It will remain the same until the next reboot. |
1.3.6.1.4.1.2272.1.4.56 | rcChasPowerManagementFanCheck | 1 | 1 | Turn on or off the Fan Check functionility of Chassis Power Management. The value takes effect only on reboot. |
1.3.6.1.4.1.2272.1.4.57 | rcChasPowerManagementFanCheckOriginalState | 1 | 1 | The on or off value of fan check which the switch has booted with. The value does not take effect till the next reboot. |
1.3.6.1.4.1.2272.1.4.58 | rcChasEsmHashIndex | 1 | 1 | This is for enabling/disabling hashing on the upper 24 bits of the UNI for ESM card |
1.3.6.1.4.1.2272.1.4.59 | rcChasSwitchFabricRedundancy | 1 | 1 | Turn on or off 2:1 Redundancy for 8011co Chassis |