Reference record for OID 1.3.6.1.4.1.231.7.1.2.1.1.4.2.12



parent
1.3.6.1.4.1.231.7.1.2.1.1.4.2 (xldv20CallP)
node code
12
node name
xldv20ContinuityCheckVcTable
dot oid
1.3.6.1.4.1.231.7.1.2.1.1.4.2.12
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) sni(231) siemensUnits(7) oenProductMibs(1) an(2) xld(1) onu(1) xldv20(4) xldv20CallP(2) xldv20ContinuityCheckVcTable(12)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) sni(231) siemensUnits(7) oenProductMibs(1) an(2) xld(1) onu(1) xldv20(4) xldv20CallP(2) xldv20ContinuityCheckVcTable(12)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) sni(231) siemensUnits(7) oenProductMibs(1) an(2) xld(1) onu(1) xldv20(4) xldv20CallP(2) xldv20ContinuityCheckVcTable(12)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) sni(231) siemensUnits(7) oenProductMibs(1) an(2) xld(1) onu(1) xldv20(4) xldv20CallP(2) xldv20ContinuityCheckVcTable(12)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) sni(231) siemensUnits(7) oenProductMibs(1) an(2) xld(1) onu(1) xldv20(4) xldv20CallP(2) xldv20ContinuityCheckVcTable(12)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) sni(231) siemensUnits(7) oenProductMibs(1) an(2) xld(1) onu(1) xldv20(4) xldv20CallP(2) xldv20ContinuityCheckVcTable(12)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/sni/siemensUnits/oenProductMibs/an/xld/onu/xldv20/xldv20CallP/xldv20ContinuityCheckVcTable
  • /iso/identified-organization/dod/internet/private/enterprises/sni/siemensUnits/oenProductMibs/an/xld/onu/xldv20/xldv20CallP/xldv20ContinuityCheckVcTable
  • /iso/org/dod/internet/private/enterprise/sni/siemensUnits/oenProductMibs/an/xld/onu/xldv20/xldv20CallP/xldv20ContinuityCheckVcTable
  • /iso/org/dod/internet/private/enterprises/sni/siemensUnits/oenProductMibs/an/xld/onu/xldv20/xldv20CallP/xldv20ContinuityCheckVcTable
  • /iso/iso-identified-organization/dod/internet/private/enterprise/sni/siemensUnits/oenProductMibs/an/xld/onu/xldv20/xldv20CallP/xldv20ContinuityCheckVcTable
  • /iso/iso-identified-organization/dod/internet/private/enterprises/sni/siemensUnits/oenProductMibs/an/xld/onu/xldv20/xldv20CallP/xldv20ContinuityCheckVcTable
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/231/7/1/2/1/1/4/2/12

    Description by mibdepot

    The continuity check configuration table for
    COC on VC level.
    Entries in this table are created when Vcl cross connects with
    enabled continuity check are created or
    when the continuity check is enabled via command.
    Entries are deleted when the continuity check is disabled
    (via xldv20ContinuityCheckControl) .

    Parsed from file xldv20.mib.txt
    Company: None
    Module: XLDV20-MIB

    Description by circitor

    The continuity check configuration table for
    COC on VC level.
    Entries in this table are created when Vcl cross connects with
    enabled continuity check are created or
    when the continuity check is enabled via command.
    Entries are deleted when the continuity check is disabled
    (via xldv20ContinuityCheckControl) .

    Parsed from file XLDV20-MIB.mib
    Module: XLDV20-MIB

    Information by oid_info

    Vendor: Fujitsu Siemens Computers
    Module: XLDV20-MIB

    [Automatically extracted from oidview.com]

    Information by mibdepot

    xldv20ContinuityCheckVcTable OBJECT-TYPE SYNTAX SEQUENCE OF Xldv20ContinuityCheckVcEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " The continuity check configuration table for COC on VC level. Entries in this table are created when Vcl cross connects with enabled continuity check are created or when the continuity check is enabled via command. Entries are deleted when the continuity check is disabled (via xldv20ContinuityCheckControl) . " ::= { xldv20CallP 12 }

    Information by circitor

    xldv20ContinuityCheckVcTable OBJECT-TYPE SYNTAX SEQUENCE OF Xldv20ContinuityCheckVcEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " The continuity check configuration table for COC on VC level. Entries in this table are created when Vcl cross connects with enabled continuity check are created or when the continuity check is enabled via command. Entries are deleted when the continuity check is disabled (via xldv20ContinuityCheckControl) . " ::= { xldv20CallP 12 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.231)

    Rothe Detlef

    Children (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.231.7.1.2.1.1.4.2.12.1 xldv20ContinuityCheckVcEntry 6 6 The entry represents the attributes of an enabled
    continuity check .
    Notifications : none.

    Brothers (11)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.231.7.1.2.1.1.4.2.1 xldv20AtmCcControl 46 92 None
    1.3.6.1.4.1.231.7.1.2.1.1.4.2.2 xldv20AtmCrossConnectTable 1 11 The ATM VP cross connect table.
    This managed entity is used to represent
    the cross-connect relationship between two Vpl terminati…
    1.3.6.1.4.1.231.7.1.2.1.1.4.2.3 xldv20VplTpTable 1 25 This table contains the entries for Vpl termination
    points (VplTp).
    1.3.6.1.4.1.231.7.1.2.1.1.4.2.4 xldv20VpcTpTable 1 31 This table contains the entries for VPC termination points.
    1.3.6.1.4.1.231.7.1.2.1.1.4.2.5 xldv20VccTpTable 1 14 VccTp table for VC termination points.
    Entries are created for Ethernet NTs
    when cross connects are created.
    Entries are deleted w…
    1.3.6.1.4.1.231.7.1.2.1.1.4.2.6 xldv20VcCrossConnectTable 1 13 The VC cross connect table for Virtual Channel
    point-to-point cross connections.
    This managed entity is used to represent
    the VC-c…
    1.3.6.1.4.1.231.7.1.2.1.1.4.2.7 xldv20VclTpTable 1 27 This table contains the entries for the VC links.
    1.3.6.1.4.1.231.7.1.2.1.1.4.2.10 xldv20EthernetConfigTable 1 8 The Ethernet Configuration Table.
    1.3.6.1.4.1.231.7.1.2.1.1.4.2.11 xldv20ContinuityCheckVpTable 1 7 The Continuity Check VP table.
    Holds entries for enabled continuity checks at VP level.
    Entries are created when Vpl cross connec…
    1.3.6.1.4.1.231.7.1.2.1.1.4.2.13 xldv20ContinuityCheckControl 8 16 None
    1.3.6.1.4.1.231.7.1.2.1.1.4.2.14 xldv20InbandTmn 4 8 None