The server blade contains fuses.
This will be true(2) is the server blade contains fuses.
The cpqRackCommonEnclosureFuseTable will contain the fuse
specific information.
Match the cpqRackServerBladeEnclosureSerialNum in this table to the
serial number in the cpqRackCommonEnclosureFanTable to get complete
information on the fuses.
Parsed from file CPQRACK.MIB.txt
Company: None
Module: CPQRACK-MIB
The server blade contains fuses.
This will be true(2) is the server blade contains fuses.
The cpqRackCommonEnclosureFuseTable will contain the fuse
specific information.
Match the cpqRackServerBladeEnclosureSerialNum in this table to the
serial number in the cpqRackCommonEnclosureFanTable to get complete
information on the fuses.
Parsed from file CPQRACK-MIB.mib
Module: CPQRACK-MIB
cpqRackServerBladeHasFuses OBJECT-TYPE SYNTAX INTEGER { false(1), true(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The server blade contains fuses. This will be true(2) is the server blade contains fuses. The cpqRackCommonEnclosureFuseTable will contain the fuse specific information. Match the cpqRackServerBladeEnclosureSerialNum in this table to the serial number in the cpqRackCommonEnclosureFanTable to get complete information on the fuses." ::= { cpqRackServerBladeEntry 13 }
Vendor: Compaq
Module: CPQRACK-MIB
[Automatically extracted from oidview.com]
cpqRackServerBladeHasFuses OBJECT-TYPE SYNTAX INTEGER { false(1), true(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The server blade contains fuses. This will be true(2) is the server blade contains fuses. The cpqRackCommonEnclosureFuseTable will contain the fuse specific information. Match the cpqRackServerBladeEnclosureSerialNum in this table to the serial number in the cpqRackCommonEnclosureFanTable to get complete information on the fuses." ::= { cpqRackServerBladeEntry 13 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.232.22.2.4.1.1.1.1 | cpqRackServerBladeRack | 0 | 0 | A number that uniquely specifies this rack. |
1.3.6.1.4.1.232.22.2.4.1.1.1.2 | cpqRackServerBladeChassis | 0 | 0 | A number that uniquely specifies this enclosure in the rack. |
1.3.6.1.4.1.232.22.2.4.1.1.1.3 | cpqRackServerBladeIndex | 0 | 0 | A number that uniquely specifies this server blade within the enclosure. |
1.3.6.1.4.1.232.22.2.4.1.1.1.4 | cpqRackServerBladeName | 0 | 0 | The name of the server blade. The string will be empty if it could not be determined. |
1.3.6.1.4.1.232.22.2.4.1.1.1.5 | cpqRackServerBladeEnclosureName | 0 | 0 | The name of the enclosure which contains the blade. The string will be empty if the enclosure does not report the name or it coul… |
1.3.6.1.4.1.232.22.2.4.1.1.1.6 | cpqRackServerBladePartNumber | 0 | 0 | The part number of the server blade. The string will be empty if the part number could not be determined. |
1.3.6.1.4.1.232.22.2.4.1.1.1.7 | cpqRackServerBladeSparePartNumber | 0 | 0 | The spare part number of the server blade. The string will be empty if the part number could not be determined. |
1.3.6.1.4.1.232.22.2.4.1.1.1.8 | cpqRackServerBladePosition | 0 | 0 | The position or slot number of the server blade within the server enclosure. This will be -1 if the server enclosure does not rep… |
1.3.6.1.4.1.232.22.2.4.1.1.1.9 | cpqRackServerBladeHeight | 0 | 0 | The height dimension of the rack space taken by the server blade expressed in millimeters. This will be -1 if the rack does not r… |
1.3.6.1.4.1.232.22.2.4.1.1.1.10 | cpqRackServerBladeWidth | 0 | 0 | The width dimension of the rack space taken by the server blade expressed in millimeters. This will be -1 if the rack does not re… |
1.3.6.1.4.1.232.22.2.4.1.1.1.11 | cpqRackServerBladeDepth | 0 | 0 | The depth dimension of the rack space taken by the server blade expressed in millimeters. This will be -1 if the rack does not re… |
1.3.6.1.4.1.232.22.2.4.1.1.1.12 | cpqRackServerBladePresent | 0 | 0 | This specifies if the server blade described is present in the enclosure. |
1.3.6.1.4.1.232.22.2.4.1.1.1.14 | cpqRackServerBladeEnclosureSerialNum | 0 | 0 | The serial number of the enclosure which contains the blade. The string will be empty if the enclosure does not report the serial… |
1.3.6.1.4.1.232.22.2.4.1.1.1.15 | cpqRackServerBladeSlotsUsed | 0 | 0 | The number of slot positions occupied by this server blade. This is used to indicate a server blade which may obscure an adjace… |
1.3.6.1.4.1.232.22.2.4.1.1.1.16 | cpqRackServerBladeSerialNum | 0 | 0 | The serial number of the server blade. The string will be empty if the system does not report the serial number function. |
1.3.6.1.4.1.232.22.2.4.1.1.1.17 | cpqRackServerBladeProductId | 0 | 0 | The product id string of the server blade. The string will be empty if the system does not report the product id function. |
1.3.6.1.4.1.232.22.2.4.1.1.1.18 | cpqRackServerBladeUid | 0 | 0 | The server blade unique identifier (UUID). The string will be empty if the blade does not report the UUID or if it could not be d… |
1.3.6.1.4.1.232.22.2.4.1.1.1.19 | cpqRackServerBladeSlotsUsedX | 0 | 0 | The number of slot positions in x-direction (from left to right) occupied by this server blade. This is used to indicate a serv… |
1.3.6.1.4.1.232.22.2.4.1.1.1.20 | cpqRackServerBladeSlotsUsedY | 0 | 0 | The number of slot positions in y-direction (from top to bottom) occupied by this server blade. This is used to indicate a serv… |
1.3.6.1.4.1.232.22.2.4.1.1.1.21 | cpqRackServerBladeStatus | 0 | 0 | The health status of the blade. This will be other(1) if the rack does not report the information or if it could not be determine… |
1.3.6.1.4.1.232.22.2.4.1.1.1.22 | cpqRackServerBladeFaultMajor | 0 | 0 | The major fault code of the blade fault reported by the enclosure manager. This will be -1 if the rack does not report the inform… |
1.3.6.1.4.1.232.22.2.4.1.1.1.23 | cpqRackServerBladeFaultMinor | 0 | 0 | The minor fault code of the blade fault reported by the enclosure manager. This will be -1 if the rack does not report the inform… |
1.3.6.1.4.1.232.22.2.4.1.1.1.24 | cpqRackServerBladeFaultDiagnosticString | 0 | 0 | The server blade fault diagnostic string. This will contain a probable cause and potential diagnostic action to be taken to rem… |
1.3.6.1.4.1.232.22.2.4.1.1.1.25 | cpqRackServerBladePowered | 0 | 0 | The power state of the blade. This will be other(1) if the rack does not report the information or if it could not be determined. |
1.3.6.1.4.1.232.22.2.4.1.1.1.26 | cpqRackServerBladeUIDState | 0 | 0 | The Unit Identifier LED. This value will be one of the following: other(1) The state of the LED could not be determined. Setting … |
1.3.6.1.4.1.232.22.2.4.1.1.1.27 | cpqRackServerBladeSystemBIOSRevision | 0 | 0 | The server blade system bios revision. The string will be empty if the blade does not report the system bios revision or if it co… |
1.3.6.1.4.1.232.22.2.4.1.1.1.28 | cpqRackServerBladeSystemBIOSFlashingStatus | 0 | 0 | Blade server system BIOS flashing / flash mode status indication. This will be other(1) if the rack does not report the informat… |
1.3.6.1.4.1.232.22.2.4.1.1.1.29 | cpqRackServerBladeHasManagementDevice | 0 | 0 | The blade server contains one or more management devices. This will be true(2) if the blade server contains managers and false (… |
1.3.6.1.4.1.232.22.2.4.1.1.1.30 | cpqRackServerBladeManagementDeviceFirmwareRevision | 0 | 0 | The server blade management device firwmware revision. The string will be empty if the blade does not report the management devic… |
1.3.6.1.4.1.232.22.2.4.1.1.1.31 | cpqRackServerBladeManagementDeviceFirmwareFlashingStatus | 0 | 0 | Blade server management device firwmware flashing / flash mode status indication. This will be other(1) if the rack does not rep… |
1.3.6.1.4.1.232.22.2.4.1.1.1.32 | cpqRackServerBladeDiagnosticAdaptorPresence | 0 | 0 | This specifies if a blade diagnostic adaptor is currently plugged into the system. |
1.3.6.1.4.1.232.22.2.4.1.1.1.33 | cpqRackServerBladeASREnabled | 0 | 0 | Indicates whether the target blade server has Automatic Service Recovery feature enabled. This will be true(2) if the blade serv… |
1.3.6.1.4.1.232.22.2.4.1.1.1.34 | cpqRackServerBladeFrontIOBlankingModeStatus | 0 | 0 | Indicates whether the target blade server has the front IO ports blanking feature enabled. This will be Active(3) if the blade s… |
1.3.6.1.4.1.232.22.2.4.1.1.1.35 | cpqRackServerBladePOSTStatus | 0 | 0 | Blade server power-on self test (POST) status. This value will be one of the following: other(1) The state of the blade POST could… |
1.3.6.1.4.1.232.22.2.4.1.1.1.36 | cpqRackServerBladePXEBootModeStatus | 0 | 0 | Indicates whether the target blade server is in PXE boot mode. This will be Active(3) if the blade server has this feature enble… |
1.3.6.1.4.1.232.22.2.4.1.1.1.37 | cpqRackServerBladePendingBootOrderChange | 0 | 0 | Blade server pending boot order setting change state. This value will be one of the following: other(1) - Unknown or cannot be de… |
1.3.6.1.4.1.232.22.2.4.1.1.1.38 | cpqRackServerBladeWattageMax | 0 | 0 | Maximum wattage the server has consumed during this power cycle. |
1.3.6.1.4.1.232.22.2.4.1.1.1.39 | cpqRackServerBladeWattageAvg | 0 | 0 | Average wattage the server is consuming, averaged over a period defined by the product. |
1.3.6.1.4.1.232.22.2.4.1.1.1.40 | cpqRackServerBladeWattageMin | 0 | 0 | Minimum wattage the server has consumed, computed from a period defined by the product. Value will be 0 if not supported, but o… |