Reference record for OID 1.3.6.1.4.1.232.22.2.4.1.1.1.37



parent
1.3.6.1.4.1.232.22.2.4.1.1.1 (cpqRackServerBladeEntry)
node code
37
node name
cpqRackServerBladePendingBootOrderChange
dot oid
1.3.6.1.4.1.232.22.2.4.1.1.1.37
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) cpqRackInfo(22) cpqRackComponent(2) cpqRackServer(4) cpqRackServerBlade(1) cpqRackServerBladeTable(1) cpqRackServerBladeEntry(1) cpqRackServerBladePendingBootOrderChange(37)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) cpqRackInfo(22) cpqRackComponent(2) cpqRackServer(4) cpqRackServerBlade(1) cpqRackServerBladeTable(1) cpqRackServerBladeEntry(1) cpqRackServerBladePendingBootOrderChange(37)}
  • ...skipped...
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) cpqRackInfo(22) cpqRackComponent(2) cpqRackServer(4) cpqRackServerBlade(1) cpqRackServerBladeTable(1) cpqRackServerBladeEntry(1) cpqRackServerBladePendingBootOrderChange(37)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) cpqRackInfo(22) cpqRackComponent(2) cpqRackServer(4) cpqRackServerBlade(1) cpqRackServerBladeTable(1) cpqRackServerBladeEntry(1) cpqRackServerBladePendingBootOrderChange(37)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) cpqRackInfo(22) cpqRackComponent(2) cpqRackServer(4) cpqRackServerBlade(1) cpqRackServerBladeTable(1) cpqRackServerBladeEntry(1) cpqRackServerBladePendingBootOrderChange(37)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) cpqRackInfo(22) cpqRackComponent(2) cpqRackServer(4) cpqRackServerBlade(1) cpqRackServerBladeTable(1) cpqRackServerBladeEntry(1) cpqRackServerBladePendingBootOrderChange(37)}
  • ...skipped...
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) cpqRackInfo(22) cpqRackComponent(2) cpqRackServer(4) cpqRackServerBlade(1) cpqRackServerBladeTable(1) cpqRackServerBladeEntry(1) cpqRackServerBladePendingBootOrderChange(37)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) cpqRackInfo(22) cpqRackComponent(2) cpqRackServer(4) cpqRackServerBlade(1) cpqRackServerBladeTable(1) cpqRackServerBladeEntry(1) cpqRackServerBladePendingBootOrderChange(37)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/cpqRackInfo/cpqRackComponent/cpqRackServer/cpqRackServerBlade/cpqRackServerBladeTable/cpqRackServerBladeEntry/cpqRackServerBladePendingBootOrderChange
  • /iso/identified-organization/dod/internet/private/enterprise/hp/cpqRackInfo/cpqRackComponent/cpqRackServer/cpqRackServerBlade/cpqRackServerBladeTable/cpqRackServerBladeEntry/cpqRackServerBladePendingBootOrderChange
  • ...skipped...
  • /iso/org/dod/internet/private/enterprise/compaq/cpqRackInfo/cpqRackComponent/cpqRackServer/cpqRackServerBlade/cpqRackServerBladeTable/cpqRackServerBladeEntry/cpqRackServerBladePendingBootOrderChange
  • /iso/org/dod/internet/private/enterprise/hp/cpqRackInfo/cpqRackComponent/cpqRackServer/cpqRackServerBlade/cpqRackServerBladeTable/cpqRackServerBladeEntry/cpqRackServerBladePendingBootOrderChange
  • /iso/org/dod/internet/private/enterprises/compaq/cpqRackInfo/cpqRackComponent/cpqRackServer/cpqRackServerBlade/cpqRackServerBladeTable/cpqRackServerBladeEntry/cpqRackServerBladePendingBootOrderChange
  • /iso/org/dod/internet/private/enterprises/hp/cpqRackInfo/cpqRackComponent/cpqRackServer/cpqRackServerBlade/cpqRackServerBladeTable/cpqRackServerBladeEntry/cpqRackServerBladePendingBootOrderChange
  • ...skipped...
  • /iso/iso-identified-organization/dod/internet/private/enterprises/compaq/cpqRackInfo/cpqRackComponent/cpqRackServer/cpqRackServerBlade/cpqRackServerBladeTable/cpqRackServerBladeEntry/cpqRackServerBladePendingBootOrderChange
  • /iso/iso-identified-organization/dod/internet/private/enterprises/hp/cpqRackInfo/cpqRackComponent/cpqRackServer/cpqRackServerBlade/cpqRackServerBladeTable/cpqRackServerBladeEntry/cpqRackServerBladePendingBootOrderChange
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/232/22/2/4/1/1/1/37

    Description by mibdepot

    Blade server pending boot order setting change state.

    This value will be one of the following:

    other(1) - Unknown or cannot be determined
    none(2) - No Changes
    firstPXE(3) - Boot To Pre-Boot eXecution (PXE) First
    firstHDD(4) - First Boot To Local HD
    firstRBSU(5) - First Boot To ROM Based Setup Utility
    oncePXE(6) - Boot To Pre-Boot eXecution (PXE) Once
    onceHDD(7) - Boot To Local HD Once
    onceRBSU(8) - Boot To ROM Based Setup Utility Once
    alwaysPXE(9) - Always Boot To Pre-Boot eXecution (PXE)
    alwaysHDD(10) - Always Boot To Local HD
    alwaysRBSU(11) - Always Boot To ROM Based Setup Utility

    This will be other(1) if the rack does not report this information or if it could not be determined.

    Parsed from file CPQRACK.MIB.txt
    Company: None
    Module: CPQRACK-MIB

    Description by circitor

    Blade server pending boot order setting change state.

    This value will be one of the following:

    other(1) - Unknown or cannot be determined
    none(2) - No Changes
    firstPXE(3) - Boot To Pre-Boot eXecution (PXE) First
    firstHDD(4) - First Boot To Local HD
    firstRBSU(5) - First Boot To ROM Based Setup Utility
    oncePXE(6) - Boot To Pre-Boot eXecution (PXE) Once
    onceHDD(7) - Boot To Local HD Once
    onceRBSU(8) - Boot To ROM Based Setup Utility Once
    alwaysPXE(9) - Always Boot To Pre-Boot eXecution (PXE)
    alwaysHDD(10) - Always Boot To Local HD
    alwaysRBSU(11) - Always Boot To ROM Based Setup Utility

    This will be other(1) if the rack does not report this information or if it could not be determined.

    Parsed from file CPQRACK-MIB.mib
    Module: CPQRACK-MIB

    Information by mibdepot

    cpqRackServerBladePendingBootOrderChange OBJECT-TYPE SYNTAX INTEGER { other(1), none(2), firstPXE(3), firstHDD(4), firstRBSU(5), oncePXE(6), onceHDD(7), onceRBSU(8), alwaysPXE(9), alwaysHDD(10), alwaysRBSU(11) } ACCESS read-write STATUS optional DESCRIPTION "Blade server pending boot order setting change state. This value will be one of the following: other(1) - Unknown or cannot be determined none(2) - No Changes firstPXE(3) - Boot To Pre-Boot eXecution (PXE) First firstHDD(4) - First Boot To Local HD firstRBSU(5) - First Boot To ROM Based Setup Utility oncePXE(6) - Boot To Pre-Boot eXecution (PXE) Once onceHDD(7) - Boot To Local HD Once onceRBSU(8) - Boot To ROM Based Setup Utility Once alwaysPXE(9) - Always Boot To Pre-Boot eXecution (PXE) alwaysHDD(10) - Always Boot To Local HD alwaysRBSU(11) - Always Boot To ROM Based Setup Utility This will be other(1) if the rack does not report this information or if it could not be determined." ::= { cpqRackServerBladeEntry 37 }

    Information by oid_info

    Vendor: Compaq
    Module: CPQRACK-MIB

    [Automatically extracted from oidview.com]

    Information by circitor

    cpqRackServerBladePendingBootOrderChange OBJECT-TYPE SYNTAX INTEGER { other(1), none(2), firstPXE(3), firstHDD(4), firstRBSU(5), oncePXE(6), onceHDD(7), onceRBSU(8), alwaysPXE(9), alwaysHDD(10), alwaysRBSU(11) } ACCESS read-write STATUS optional DESCRIPTION "Blade server pending boot order setting change state. This value will be one of the following: other(1) - Unknown or cannot be determined none(2) - No Changes firstPXE(3) - Boot To Pre-Boot eXecution (PXE) First firstHDD(4) - First Boot To Local HD firstRBSU(5) - First Boot To ROM Based Setup Utility oncePXE(6) - Boot To Pre-Boot eXecution (PXE) Once onceHDD(7) - Boot To Local HD Once onceRBSU(8) - Boot To ROM Based Setup Utility Once alwaysPXE(9) - Always Boot To Pre-Boot eXecution (PXE) alwaysHDD(10) - Always Boot To Local HD alwaysRBSU(11) - Always Boot To ROM Based Setup Utility This will be other(1) if the rack does not report this information or if it could not be determined." ::= { cpqRackServerBladeEntry 37 }

    Brothers (39)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.232.22.2.4.1.1.1.1 cpqRackServerBladeRack 0 0 A number that uniquely specifies this rack.
    1.3.6.1.4.1.232.22.2.4.1.1.1.2 cpqRackServerBladeChassis 0 0 A number that uniquely specifies this enclosure in the rack.
    1.3.6.1.4.1.232.22.2.4.1.1.1.3 cpqRackServerBladeIndex 0 0 A number that uniquely specifies this server blade within the enclosure.
    1.3.6.1.4.1.232.22.2.4.1.1.1.4 cpqRackServerBladeName 0 0 The name of the server blade.

    The string will be empty if it could not be determined.
    1.3.6.1.4.1.232.22.2.4.1.1.1.5 cpqRackServerBladeEnclosureName 0 0 The name of the enclosure which contains the blade.

    The string will be empty if the enclosure does not report the
    name or it coul…
    1.3.6.1.4.1.232.22.2.4.1.1.1.6 cpqRackServerBladePartNumber 0 0 The part number of the server blade.

    The string will be empty if the part number could not be
    determined.
    1.3.6.1.4.1.232.22.2.4.1.1.1.7 cpqRackServerBladeSparePartNumber 0 0 The spare part number of the server blade.

    The string will be empty if the part number could not be
    determined.
    1.3.6.1.4.1.232.22.2.4.1.1.1.8 cpqRackServerBladePosition 0 0 The position or slot number of the server blade within the
    server enclosure.

    This will be -1 if the server enclosure does not rep…
    1.3.6.1.4.1.232.22.2.4.1.1.1.9 cpqRackServerBladeHeight 0 0 The height dimension of the rack space taken by the server
    blade expressed in millimeters.

    This will be -1 if the rack does not r…
    1.3.6.1.4.1.232.22.2.4.1.1.1.10 cpqRackServerBladeWidth 0 0 The width dimension of the rack space taken by the server
    blade expressed in millimeters.

    This will be -1 if the rack does not re…
    1.3.6.1.4.1.232.22.2.4.1.1.1.11 cpqRackServerBladeDepth 0 0 The depth dimension of the rack space taken by the server
    blade expressed in millimeters.

    This will be -1 if the rack does not re…
    1.3.6.1.4.1.232.22.2.4.1.1.1.12 cpqRackServerBladePresent 0 0 This specifies if the server blade described is present in the
    enclosure.
    1.3.6.1.4.1.232.22.2.4.1.1.1.13 cpqRackServerBladeHasFuses 0 0 The server blade contains fuses.

    This will be true(2) is the server blade contains fuses.
    The cpqRackCommonEnclosureFuseTable wil…
    1.3.6.1.4.1.232.22.2.4.1.1.1.14 cpqRackServerBladeEnclosureSerialNum 0 0 The serial number of the enclosure which contains the blade.

    The string will be empty if the enclosure does not report the
    serial…
    1.3.6.1.4.1.232.22.2.4.1.1.1.15 cpqRackServerBladeSlotsUsed 0 0 The number of slot positions occupied by this server blade. This
    is used to indicate a server blade which may obscure an adjace…
    1.3.6.1.4.1.232.22.2.4.1.1.1.16 cpqRackServerBladeSerialNum 0 0 The serial number of the server blade.

    The string will be empty if the system does not report the
    serial number function.
    1.3.6.1.4.1.232.22.2.4.1.1.1.17 cpqRackServerBladeProductId 0 0 The product id string of the server blade.

    The string will be empty if the system does not report the
    product id function.
    1.3.6.1.4.1.232.22.2.4.1.1.1.18 cpqRackServerBladeUid 0 0 The server blade unique identifier (UUID).

    The string will be empty if the blade does not report the
    UUID or if it could not be d…
    1.3.6.1.4.1.232.22.2.4.1.1.1.19 cpqRackServerBladeSlotsUsedX 0 0 The number of slot positions in x-direction (from left to right)
    occupied by this server blade. This is used to indicate a serv…
    1.3.6.1.4.1.232.22.2.4.1.1.1.20 cpqRackServerBladeSlotsUsedY 0 0 The number of slot positions in y-direction (from top to bottom)
    occupied by this server blade. This is used to indicate a serv…
    1.3.6.1.4.1.232.22.2.4.1.1.1.21 cpqRackServerBladeStatus 0 0 The health status of the blade.

    This will be other(1) if the rack does not report the information
    or if it could not be determine…
    1.3.6.1.4.1.232.22.2.4.1.1.1.22 cpqRackServerBladeFaultMajor 0 0 The major fault code of the blade fault
    reported by the enclosure manager.

    This will be -1 if the rack does not report the inform…
    1.3.6.1.4.1.232.22.2.4.1.1.1.23 cpqRackServerBladeFaultMinor 0 0 The minor fault code of the blade fault
    reported by the enclosure manager.

    This will be -1 if the rack does not report the inform…
    1.3.6.1.4.1.232.22.2.4.1.1.1.24 cpqRackServerBladeFaultDiagnosticString 0 0 The server blade fault diagnostic string. This will contain a probable
    cause and potential diagnostic action to be taken to rem…
    1.3.6.1.4.1.232.22.2.4.1.1.1.25 cpqRackServerBladePowered 0 0 The power state of the blade.

    This will be other(1) if the rack does not report the information or if it could not be determined.
    1.3.6.1.4.1.232.22.2.4.1.1.1.26 cpqRackServerBladeUIDState 0 0 The Unit Identifier LED.

    This value will be one of the following:

    other(1)
    The state of the LED could not be determined. Setting …
    1.3.6.1.4.1.232.22.2.4.1.1.1.27 cpqRackServerBladeSystemBIOSRevision 0 0 The server blade system bios revision.

    The string will be empty if the blade does not report the
    system bios revision or if it co…
    1.3.6.1.4.1.232.22.2.4.1.1.1.28 cpqRackServerBladeSystemBIOSFlashingStatus 0 0 Blade server system BIOS flashing / flash mode status indication.

    This will be other(1) if the rack does not report the informat…
    1.3.6.1.4.1.232.22.2.4.1.1.1.29 cpqRackServerBladeHasManagementDevice 0 0 The blade server contains one or more management devices.

    This will be true(2) if the blade server contains managers and false (…
    1.3.6.1.4.1.232.22.2.4.1.1.1.30 cpqRackServerBladeManagementDeviceFirmwareRevision 0 0 The server blade management device firwmware revision.

    The string will be empty if the blade does not report the
    management devic…
    1.3.6.1.4.1.232.22.2.4.1.1.1.31 cpqRackServerBladeManagementDeviceFirmwareFlashingStatus 0 0 Blade server management device firwmware flashing / flash mode status indication.

    This will be other(1) if the rack does not rep…
    1.3.6.1.4.1.232.22.2.4.1.1.1.32 cpqRackServerBladeDiagnosticAdaptorPresence 0 0 This specifies if a blade diagnostic adaptor is currently plugged into the system.
    1.3.6.1.4.1.232.22.2.4.1.1.1.33 cpqRackServerBladeASREnabled 0 0 Indicates whether the target blade server has Automatic Service Recovery feature enabled.

    This will be true(2) if the blade serv…
    1.3.6.1.4.1.232.22.2.4.1.1.1.34 cpqRackServerBladeFrontIOBlankingModeStatus 0 0 Indicates whether the target blade server has the front IO ports blanking feature enabled.

    This will be Active(3) if the blade s…
    1.3.6.1.4.1.232.22.2.4.1.1.1.35 cpqRackServerBladePOSTStatus 0 0 Blade server power-on self test (POST) status.

    This value will be one of the following:

    other(1)
    The state of the blade POST could…
    1.3.6.1.4.1.232.22.2.4.1.1.1.36 cpqRackServerBladePXEBootModeStatus 0 0 Indicates whether the target blade server is in PXE boot mode.

    This will be Active(3) if the blade server has this feature enble…
    1.3.6.1.4.1.232.22.2.4.1.1.1.38 cpqRackServerBladeWattageMax 0 0 Maximum wattage the server has consumed during this power cycle.
    1.3.6.1.4.1.232.22.2.4.1.1.1.39 cpqRackServerBladeWattageAvg 0 0 Average wattage the server is consuming, averaged over a period defined by the product.
    1.3.6.1.4.1.232.22.2.4.1.1.1.40 cpqRackServerBladeWattageMin 0 0 Minimum wattage the server has consumed, computed from a period defined by the product. Value
    will be 0 if not supported, but o…