Physical Drive Error Log User Description.
This is a string built by the agent which contains the Reference
Time (cpqDaPhyDrvTime) and a brief description of the disk error
associated with the particular error log entry. This field is
being deprecated, and future management station applications
should be aware that this field may not contain ASCII
string data.
Parsed from file CPQIDA2.MIB.txt
Company: None
Module: CPQIDA-MIB
Physical Drive Error Log User Description.
This is a string built by the agent which contains the Reference
Time (cpqDaPhyDrvTime) and a brief description of the disk error
associated with the particular error log entry. This field is
being deprecated, and future management station applications
should be aware that this field may not contain ASCII
string data.
Parsed from file CPQIDA-MIB.mib
Module: CPQIDA-MIB
cpqDaPhyDrvUserDesc OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS deprecated DESCRIPTION "Physical Drive Error Log User Description. This is a string built by the agent which contains the Reference Time (cpqDaPhyDrvTime) and a brief description of the disk error associated with the particular error log entry. This field is being deprecated, and future management station applications should be aware that this field may not contain ASCII string data." ::= { cpqDaPhyDrvErrEntry 14 }
Vendor: Compaq
Module: CPQIDA-MIB
[Automatically extracted from oidview.com]
cpqDaPhyDrvUserDesc OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS deprecated DESCRIPTION "Physical Drive Error Log User Description. This is a string built by the agent which contains the Reference Time (cpqDaPhyDrvTime) and a brief description of the disk error associated with the particular error log entry. This field is being deprecated, and future management station applications should be aware that this field may not contain ASCII string data." ::= { cpqDaPhyDrvErrEntry 14 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.232.3.2.5.2.1.1 | cpqDaPhyDrvErrCntlrIndex | 0 | 0 | Drive Array Physical Drive Error Log Controller Index. This index maps the physical drive back to the controller to which it is a… |
1.3.6.1.4.1.232.3.2.5.2.1.2 | cpqDaPhyDrvErrIDIndex | 0 | 0 | Drive Array Physical Drive Error Log Index. This index is used for selecting the physical drive table entry. This number, along w… |
1.3.6.1.4.1.232.3.2.5.2.1.3 | cpqDaPhyDrvErrIndex | 0 | 0 | Drive Array Physical Drive Error Log Index. This index is used for selecting the physical drive table entry. This number, along w… |
1.3.6.1.4.1.232.3.2.5.2.1.4 | cpqDaPhyDrvErrType | 0 | 0 | Physical Drive Error Log Error Type. The type of error in the error log. The valid types are: Other (1) Indicates that the instru… |
1.3.6.1.4.1.232.3.2.5.2.1.5 | cpqDaPhyDrvScsiOp | 0 | 0 | Physical Drive Error Log SCSI Operation. This is the SCSI Command Operation Code byte associated with the error log entry. For f… |
1.3.6.1.4.1.232.3.2.5.2.1.6 | cpqDaPhyDrvScsiStatus | 0 | 0 | Physical Drive Error Log SCSI Status. This is the SCSI Status Code byte associated with the error log entry. For further specifi… |
1.3.6.1.4.1.232.3.2.5.2.1.7 | cpqDaPhyDrvCamStatus | 0 | 0 | Physical Drive Error Log CAM Status. This is the SCSI CAM Status byte associated with the error log entry. For further specifica… |
1.3.6.1.4.1.232.3.2.5.2.1.8 | cpqDaPhyDrvSenseKey | 0 | 0 | Physical Drive Error Log Sense Key. This is the SCSI Sense Key byte associated with the error log entry. For further specificati… |
1.3.6.1.4.1.232.3.2.5.2.1.9 | cpqDaPhyDrvQualifier | 0 | 0 | Physical Drive Error Log Qualifier. This is the SCSI Additional Sense Code Qualifier byte (as returned by the Request Sense comma… |
1.3.6.1.4.1.232.3.2.5.2.1.10 | cpqDaPhyDrvSenseCode | 0 | 0 | Physical Drive Error Log Sense Code. This is the SCSI Sense Code associated with the error log entry. For further specifications … |
1.3.6.1.4.1.232.3.2.5.2.1.11 | cpqDaPhyDrvBlockValid | 0 | 0 | Physical Drive Error Log Block Address Is Valid. The valid values are: False (1) Indicates that the Block Address object (cpqDaPhy… |
1.3.6.1.4.1.232.3.2.5.2.1.12 | cpqDaPhyDrvBlock | 0 | 0 | Physical Drive Error Log Block Address. This is the SCSI Block Address (as returned by the Request Sense Command) associated with… |
1.3.6.1.4.1.232.3.2.5.2.1.13 | cpqDaPhyDrvTime | 0 | 0 | Physical Drive Error Log Reference Time. This gives a relative time stamp as to when the error log entry occurred. The Reference… |
1.3.6.1.4.1.232.3.2.5.2.1.15 | cpqDaPhyDrvErrDesc | 0 | 0 | The index used to display an error associated with a physical drive. This number refers to an entry in a list of error strings en… |