Reference record for OID 1.3.6.1.4.1.232.3.2.5.2.1.15



parent
1.3.6.1.4.1.232.3.2.5.2.1 (cpqDaPhyDrvErrEntry)
node code
15
node name
cpqDaPhyDrvErrDesc
dot oid
1.3.6.1.4.1.232.3.2.5.2.1.15
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) cpqDriveArray(3) cpqDaComponent(2) cpqDaPhyDrv(5) cpqDaPhyDrvErrTable(2) cpqDaPhyDrvErrEntry(1) cpqDaPhyDrvErrDesc(15)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) cpqDriveArray(3) cpqDaComponent(2) cpqDaPhyDrv(5) cpqDaPhyDrvErrTable(2) cpqDaPhyDrvErrEntry(1) cpqDaPhyDrvErrDesc(15)}
  • ...skipped...
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) cpqDriveArray(3) cpqDaComponent(2) cpqDaPhyDrv(5) cpqDaPhyDrvErrTable(2) cpqDaPhyDrvErrEntry(1) cpqDaPhyDrvErrDesc(15)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) cpqDriveArray(3) cpqDaComponent(2) cpqDaPhyDrv(5) cpqDaPhyDrvErrTable(2) cpqDaPhyDrvErrEntry(1) cpqDaPhyDrvErrDesc(15)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) cpqDriveArray(3) cpqDaComponent(2) cpqDaPhyDrv(5) cpqDaPhyDrvErrTable(2) cpqDaPhyDrvErrEntry(1) cpqDaPhyDrvErrDesc(15)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) cpqDriveArray(3) cpqDaComponent(2) cpqDaPhyDrv(5) cpqDaPhyDrvErrTable(2) cpqDaPhyDrvErrEntry(1) cpqDaPhyDrvErrDesc(15)}
  • ...skipped...
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) cpqDriveArray(3) cpqDaComponent(2) cpqDaPhyDrv(5) cpqDaPhyDrvErrTable(2) cpqDaPhyDrvErrEntry(1) cpqDaPhyDrvErrDesc(15)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) cpqDriveArray(3) cpqDaComponent(2) cpqDaPhyDrv(5) cpqDaPhyDrvErrTable(2) cpqDaPhyDrvErrEntry(1) cpqDaPhyDrvErrDesc(15)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/cpqDriveArray/cpqDaComponent/cpqDaPhyDrv/cpqDaPhyDrvErrTable/cpqDaPhyDrvErrEntry/cpqDaPhyDrvErrDesc
  • /iso/identified-organization/dod/internet/private/enterprise/hp/cpqDriveArray/cpqDaComponent/cpqDaPhyDrv/cpqDaPhyDrvErrTable/cpqDaPhyDrvErrEntry/cpqDaPhyDrvErrDesc
  • ...skipped...
  • /iso/org/dod/internet/private/enterprise/compaq/cpqDriveArray/cpqDaComponent/cpqDaPhyDrv/cpqDaPhyDrvErrTable/cpqDaPhyDrvErrEntry/cpqDaPhyDrvErrDesc
  • /iso/org/dod/internet/private/enterprise/hp/cpqDriveArray/cpqDaComponent/cpqDaPhyDrv/cpqDaPhyDrvErrTable/cpqDaPhyDrvErrEntry/cpqDaPhyDrvErrDesc
  • /iso/org/dod/internet/private/enterprises/compaq/cpqDriveArray/cpqDaComponent/cpqDaPhyDrv/cpqDaPhyDrvErrTable/cpqDaPhyDrvErrEntry/cpqDaPhyDrvErrDesc
  • /iso/org/dod/internet/private/enterprises/hp/cpqDriveArray/cpqDaComponent/cpqDaPhyDrv/cpqDaPhyDrvErrTable/cpqDaPhyDrvErrEntry/cpqDaPhyDrvErrDesc
  • ...skipped...
  • /iso/iso-identified-organization/dod/internet/private/enterprises/compaq/cpqDriveArray/cpqDaComponent/cpqDaPhyDrv/cpqDaPhyDrvErrTable/cpqDaPhyDrvErrEntry/cpqDaPhyDrvErrDesc
  • /iso/iso-identified-organization/dod/internet/private/enterprises/hp/cpqDriveArray/cpqDaComponent/cpqDaPhyDrv/cpqDaPhyDrvErrTable/cpqDaPhyDrvErrEntry/cpqDaPhyDrvErrDesc
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/232/3/2/5/2/1/15

    Description by mibdepot

    The index used to display an error associated with a physical drive.

    This number refers to an entry in a list of error strings
    enumerating the possible physical drive errors associated with
    a particular physical disk drive.

    The valid values are:

    DriveFailure (1)
    The Management Station should display the following string:
    'Drive Failure'.

    CommFailure(2)
    The Management Station should display the following string:
    'Communication Failure'.

    DriveIOError(3)
    The Management Station should display the following string:
    'Drive I/O Error'.

    SCSICommError(4)
    The Management Station should display the following string:
    'SCSI Communication Error'.

    CompaqUpgradeRequired(5)
    The Management Station should display the following string:
    'Compaq EISA Configuration Utility or OS upgrade required'.

    DriveWriteProtected(6)
    The Management Station should display the following string:
    'Drive Write Protected - Check Drive Jumpers'.

    InvalidRequest(7)
    The Management Station should display the following string:
    'Invalid Request'.

    SCSIMessageError(8)
    The Management Station should display the following string:
    'SCSI Message Error'.

    ControllerFailure(9)
    The Management Station should display the following string:
    'Controller Failure'.

    InternalExternalConflict(10)
    The Management Station should display the following string:
    'Internal/External Conflict on Port 1'.

    InternalDriveFailure(11)
    The Management Station should display the following string:
    'Internal Drive Failure'.

    SCSIErrorOutOfRange(12)
    The Management Station should display the following string:
    'SCSI Error, Sense Code = %xh' where %x is the value of the
    cpqDaPhyDrvSenseCode object. This index will only be provided
    if the specified object exceeds the valid range.

    CAMErrorOutOfRange(13)
    The Management Station should display the following string:
    'CAM Error, CAM status =%xh' where %x is the value of the
    cpqDaPhyDrvCamStatus object. This index will only be provided
    if the specified object exceeds the valid range.

    ErrorTypeOutOfRange(14)
    The Management Station should display the following string:
    'Error type =%xh' where %x is the value of the
    cpqDaPhyDrvErrType object. This index will only be provided
    if the specified object exceeds the valid range.

    Parsed from file CPQIDA2.MIB.txt
    Company: None
    Module: CPQIDA-MIB

    Description by circitor

    The index used to display an error associated with a physical drive.

    This number refers to an entry in a list of error strings
    enumerating the possible physical drive errors associated with
    a particular physical disk drive.

    The valid values are:

    DriveFailure (1)
    The Management Station should display the following string:
    'Drive Failure'.

    CommFailure(2)
    The Management Station should display the following string:
    'Communication Failure'.

    DriveIOError(3)
    The Management Station should display the following string:
    'Drive I/O Error'.

    SCSICommError(4)
    The Management Station should display the following string:
    'SCSI Communication Error'.

    UpgradeRequired(5)
    The Management Station should display the following string:
    'Configuration Utility or OS upgrade required'.

    DriveWriteProtected(6)
    The Management Station should display the following string:
    'Drive Write Protected - Check Drive Jumpers'.

    InvalidRequest(7)
    The Management Station should display the following string:
    'Invalid Request'.

    SCSIMessageError(8)
    The Management Station should display the following string:
    'SCSI Message Error'.

    ControllerFailure(9)
    The Management Station should display the following string:
    'Controller Failure'.

    InternalExternalConflict(10)
    The Management Station should display the following string:
    'Internal/External Conflict on Port 1'.

    InternalDriveFailure(11)
    The Management Station should display the following string:
    'Internal Drive Failure'.

    SCSIErrorOutOfRange(12)
    The Management Station should display the following string:
    'SCSI Error, Sense Code = %xh' where %x is the value of the
    cpqDaPhyDrvSenseCode object. This index will only be provided
    if the specified object exceeds the valid range.

    CAMErrorOutOfRange(13)
    The Management Station should display the following string:
    'CAM Error, CAM status =%xh' where %x is the value of the
    cpqDaPhyDrvCamStatus object. This index will only be provided
    if the specified object exceeds the valid range.

    ErrorTypeOutOfRange(14)
    The Management Station should display the following string:
    'Error type =%xh' where %x is the value of the
    cpqDaPhyDrvErrType object. This index will only be provided
    if the specified object exceeds the valid range.

    Parsed from file CPQIDA-MIB.mib
    Module: CPQIDA-MIB

    Information by mibdepot

    cpqDaPhyDrvErrDesc OBJECT-TYPE SYNTAX INTEGER { driveFailure(1), commFailure(2), driveIOError(3), scsiCommError(4), compaqUpgradeRequired(5), driveWriteProtected(6), invalidRequest(7), scsiMessageError(8), controllerFailure(9), internExternConflict(10), internalDriveFailure(11), scsiErrorOutOfRange(12), camErrorOutOfRange(13), errorTypeOutOfRange(14) } ACCESS read-only STATUS mandatory DESCRIPTION "The index used to display an error associated with a physical drive. This number refers to an entry in a list of error strings enumerating the possible physical drive errors associated with a particular physical disk drive. The valid values are: DriveFailure (1) The Management Station should display the following string: 'Drive Failure'. CommFailure(2) The Management Station should display the following string: 'Communication Failure'. DriveIOError(3) The Management Station should display the following string: 'Drive I/O Error'. SCSICommError(4) The Management Station should display the following string: 'SCSI Communication Error'. CompaqUpgradeRequired(5) The Management Station should display the following string: 'Compaq EISA Configuration Utility or OS upgrade required'. DriveWriteProtected(6) The Management Station should display the following string: 'Drive Write Protected - Check Drive Jumpers'. InvalidRequest(7) The Management Station should display the following string: 'Invalid Request'. SCSIMessageError(8) The Management Station should display the following string: 'SCSI Message Error'. ControllerFailure(9) The Management Station should display the following string: 'Controller Failure'. InternalExternalConflict(10) The Management Station should display the following string: 'Internal/External Conflict on Port 1'. InternalDriveFailure(11) The Management Station should display the following string: 'Internal Drive Failure'. SCSIErrorOutOfRange(12) The Management Station should display the following string: 'SCSI Error, Sense Code = %xh' where %x is the value of the cpqDaPhyDrvSenseCode object. This index will only be provided if the specified object exceeds the valid range. CAMErrorOutOfRange(13) The Management Station should display the following string: 'CAM Error, CAM status =%xh' where %x is the value of the cpqDaPhyDrvCamStatus object. This index will only be provided if the specified object exceeds the valid range. ErrorTypeOutOfRange(14) The Management Station should display the following string: 'Error type =%xh' where %x is the value of the cpqDaPhyDrvErrType object. This index will only be provided if the specified object exceeds the valid range. " ::= { cpqDaPhyDrvErrEntry 15 }

    Information by oid_info

    Vendor: Compaq
    Module: CPQIDA-MIB

    [Automatically extracted from oidview.com]

    Information by circitor

    cpqDaPhyDrvErrDesc OBJECT-TYPE SYNTAX INTEGER { driveFailure(1), commFailure(2), driveIOError(3), scsiCommError(4), compaqUpgradeRequired(5), driveWriteProtected(6), invalidRequest(7), scsiMessageError(8), controllerFailure(9), internExternConflict(10), internalDriveFailure(11), scsiErrorOutOfRange(12), camErrorOutOfRange(13), errorTypeOutOfRange(14) } ACCESS read-only STATUS mandatory DESCRIPTION "The index used to display an error associated with a physical drive. This number refers to an entry in a list of error strings enumerating the possible physical drive errors associated with a particular physical disk drive. The valid values are: DriveFailure (1) The Management Station should display the following string: 'Drive Failure'. CommFailure(2) The Management Station should display the following string: 'Communication Failure'. DriveIOError(3) The Management Station should display the following string: 'Drive I/O Error'. SCSICommError(4) The Management Station should display the following string: 'SCSI Communication Error'. UpgradeRequired(5) The Management Station should display the following string: 'Configuration Utility or OS upgrade required'. DriveWriteProtected(6) The Management Station should display the following string: 'Drive Write Protected - Check Drive Jumpers'. InvalidRequest(7) The Management Station should display the following string: 'Invalid Request'. SCSIMessageError(8) The Management Station should display the following string: 'SCSI Message Error'. ControllerFailure(9) The Management Station should display the following string: 'Controller Failure'. InternalExternalConflict(10) The Management Station should display the following string: 'Internal/External Conflict on Port 1'. InternalDriveFailure(11) The Management Station should display the following string: 'Internal Drive Failure'. SCSIErrorOutOfRange(12) The Management Station should display the following string: 'SCSI Error, Sense Code = %xh' where %x is the value of the cpqDaPhyDrvSenseCode object. This index will only be provided if the specified object exceeds the valid range. CAMErrorOutOfRange(13) The Management Station should display the following string: 'CAM Error, CAM status =%xh' where %x is the value of the cpqDaPhyDrvCamStatus object. This index will only be provided if the specified object exceeds the valid range. ErrorTypeOutOfRange(14) The Management Station should display the following string: 'Error type =%xh' where %x is the value of the cpqDaPhyDrvErrType object. This index will only be provided if the specified object exceeds the valid range. " ::= { cpqDaPhyDrvErrEntry 15 }

    Brothers (14)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.232.3.2.5.2.1.1 cpqDaPhyDrvErrCntlrIndex 0 0 Drive Array Physical Drive Error Log Controller Index.

    This index maps the physical drive back to the controller to
    which it is a…
    1.3.6.1.4.1.232.3.2.5.2.1.2 cpqDaPhyDrvErrIDIndex 0 0 Drive Array Physical Drive Error Log Index.

    This index is used for selecting the physical drive table entry.
    This number, along w…
    1.3.6.1.4.1.232.3.2.5.2.1.3 cpqDaPhyDrvErrIndex 0 0 Drive Array Physical Drive Error Log Index.

    This index is used for selecting the physical drive table entry.
    This number, along w…
    1.3.6.1.4.1.232.3.2.5.2.1.4 cpqDaPhyDrvErrType 0 0 Physical Drive Error Log Error Type.

    The type of error in the error log. The valid types are:

    Other (1)
    Indicates that the instru…
    1.3.6.1.4.1.232.3.2.5.2.1.5 cpqDaPhyDrvScsiOp 0 0 Physical Drive Error Log SCSI Operation.

    This is the SCSI Command Operation Code byte associated with the
    error log entry. For f…
    1.3.6.1.4.1.232.3.2.5.2.1.6 cpqDaPhyDrvScsiStatus 0 0 Physical Drive Error Log SCSI Status.

    This is the SCSI Status Code byte associated with the error log
    entry. For further specifi…
    1.3.6.1.4.1.232.3.2.5.2.1.7 cpqDaPhyDrvCamStatus 0 0 Physical Drive Error Log CAM Status.

    This is the SCSI CAM Status byte associated with the error log
    entry. For further specifica…
    1.3.6.1.4.1.232.3.2.5.2.1.8 cpqDaPhyDrvSenseKey 0 0 Physical Drive Error Log Sense Key.

    This is the SCSI Sense Key byte associated with the error log
    entry. For further specificati…
    1.3.6.1.4.1.232.3.2.5.2.1.9 cpqDaPhyDrvQualifier 0 0 Physical Drive Error Log Qualifier.

    This is the SCSI Additional Sense Code Qualifier byte (as returned
    by the Request Sense comma…
    1.3.6.1.4.1.232.3.2.5.2.1.10 cpqDaPhyDrvSenseCode 0 0 Physical Drive Error Log Sense Code.

    This is the SCSI Sense Code associated with the error log entry.
    For further specifications …
    1.3.6.1.4.1.232.3.2.5.2.1.11 cpqDaPhyDrvBlockValid 0 0 Physical Drive Error Log Block Address Is Valid.

    The valid values are:

    False (1)
    Indicates that the Block Address object (cpqDaPhy…
    1.3.6.1.4.1.232.3.2.5.2.1.12 cpqDaPhyDrvBlock 0 0 Physical Drive Error Log Block Address.

    This is the SCSI Block Address (as returned by the Request Sense
    Command) associated with…
    1.3.6.1.4.1.232.3.2.5.2.1.13 cpqDaPhyDrvTime 0 0 Physical Drive Error Log Reference Time.

    This gives a relative time stamp as to when the error log entry
    occurred. The Reference…
    1.3.6.1.4.1.232.3.2.5.2.1.14 cpqDaPhyDrvUserDesc 0 0 Physical Drive Error Log User Description.

    This is a string built by the agent which contains the Reference
    Time (cpqDaPhyDrvTime…