This variable defines automatic fan control.
In mode 'auto' the fans are automatically adjusted
depending on the current temperature.
In mode 'high' all fans remain at maximum speed.
Parsed from file mibsysxl.mib.txt
Company: bintec
Module: BIANCA-XL-MIBSYS-MIB
Child arc 0 is used to translate between SNMPv1 and SNMPv2 notification parameters as explained in IETF RFC 2576, section 3.
sysConfigFanControl OBJECT-TYPE SYNTAX INTEGER { auto(1), high(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This variable defines automatic fan control. In mode 'auto' the fans are automatically adjusted depending on the current temperature. In mode 'high' all fans remain at maximum speed." ::= { sysConfig 8 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.272.4.15.8.0 | sysConfigFanControl | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.272.4.15.1 | sysConfigLcdBrightness | 1 | 1 | This variable allows to control the brightness of the LCD display. Lower values mean less, higher values mean more brightness. Ze… |
1.3.6.1.4.1.272.4.15.2 | sysConfigLcdContrast | 1 | 1 | This variable allows to control the contrast of the LCD display. Lower values mean less, higher values mean more contrast. Zero m… |
1.3.6.1.4.1.272.4.15.3 | sysConfigLcdConfigure | 1 | 1 | This variable determines whether it is possible to configure the brick by using the LCD display and the buttons. |
1.3.6.1.4.1.272.4.15.4 | sysConfigTemperature | 1 | 1 | This variable shows the actual system temperature measured inside the brick in the units Fahrenheit or Celsius. |
1.3.6.1.4.1.272.4.15.5 | sysConfigTempUnit | 1 | 1 | This variable defines the unit of sysConfigTemperature, either Celsius or Fahrenheit. |
1.3.6.1.4.1.272.4.15.6 | sysConfigTempAlarmTrap | 1 | 1 | If the system temperature raises above this threshold, a alarm trap is generated every 60 seconds. |
1.3.6.1.4.1.272.4.15.7 | sysConfigTempAlarmRelay | 1 | 1 | If the system temperature raises above this threshold, the alarm relay is activated. It is deactivated again when the system temp… |
1.3.6.1.4.1.272.4.15.9 | sysConfigFan1 | 1 | 1 | This variable shows, whether the fan is turning or not. |
1.3.6.1.4.1.272.4.15.10 | sysConfigFan2 | 1 | 1 | This variable shows, whether the fan is turning or not. |
1.3.6.1.4.1.272.4.15.11 | sysConfigFan3 | 1 | 1 | This variable shows, whether the fan is turning or not. |
1.3.6.1.4.1.272.4.15.12 | sysConfigFan4 | 1 | 1 | This variable shows, whether the fan is turning or not. |