Each entry corresponds to a single span configuration
profile. Each profile contains a set of span configuration
parameters. The configuration parameters in a profile are
applied to those lines referencing that profile (see the
hdsl2ShdslSpanConfProfile object). Profiles may be
created/deleted only by the system.
Parsed from file mibhdsl2shdsl.mib.txt
Company: bintec
Module: BIANCA-BRICK-HDSL2SHDSL-MIB
Vendor: Bintec
Module: BIANCA-BRICK-HDSL2SHDSL-MIB (mibhdsl2shdsl.mib)
Type: ENTRY
Access: not-accessible
Syntax: Hdsl2ShdslSpanConfProfileEntry
Automatically extracted from www.mibdepot.com
hdsl2ShdslSpanConfProfileEntry OBJECT-TYPE SYNTAX Hdsl2ShdslSpanConfProfileEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry corresponds to a single span configuration profile. Each profile contains a set of span configuration parameters. The configuration parameters in a profile are applied to those lines referencing that profile (see the hdsl2ShdslSpanConfProfile object). Profiles may be created/deleted only by the system." INDEX { hdsl2ShdslSpanConfProfileName } ::= { hdsl2ShdslSpanConfProfileTable 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.272.4.35.1.1.10.1.1 | hdsl2ShdslSpanConfProfileName | 0 | 0 | This object is the unique index associated with this profile. Entries in this table are referenced via the object hdsl2ShdslSpanC… |
1.3.6.1.4.1.272.4.35.1.1.10.1.2 | hdsl2ShdslSpanConfWireInterface | 0 | 0 | This object configures the two-wire or optional four-wire operation for SHDSL Lines. |
1.3.6.1.4.1.272.4.35.1.1.10.1.3 | hdsl2ShdslSpanConfMinLineRate | 0 | 0 | This object configures the minimum transmission rate for the associated SHDSL Line in bits-per-second (bps). If the minimum line… |
1.3.6.1.4.1.272.4.35.1.1.10.1.4 | hdsl2ShdslSpanConfMaxLineRate | 0 | 0 | This object configures the maximum transmission rate for the associated SHDSL Line in bits-per-second (bps). If the minimum line… |
1.3.6.1.4.1.272.4.35.1.1.10.1.5 | hdsl2ShdslSpanConfPSD | 0 | 0 | This object configures use of symmetric/asymmetric PSD (Power Spectral Density) Mask for the associated SHDSL Line. Support for … |
1.3.6.1.4.1.272.4.35.1.1.10.1.6 | hdsl2ShdslSpanConfTransmissionMode | 0 | 0 | hdsl2ShdslSpanConftransmissionMode |
1.3.6.1.4.1.272.4.35.1.1.10.1.7 | hdsl2ShdslSpanConfRemoteEnabled | 0 | 0 | This object enables/disables support for remote management of the units in a SHDSL line from the STU-R via the EOC. |
1.3.6.1.4.1.272.4.35.1.1.10.1.9 | hdsl2ShdslSpanConfCurrCondTargetMarginDown | 0 | 0 | This object specifies the downstream current condition target SNR margin for a SHDSL line. The SNR margin is the difference betw… |
1.3.6.1.4.1.272.4.35.1.1.10.1.10 | hdsl2ShdslSpanConfWorstCaseTargetMarginDown | 0 | 0 | This object specifies the downstream worst case target SNR margin for a SHDSL line. The SNR margin is the difference between the… |
1.3.6.1.4.1.272.4.35.1.1.10.1.11 | hdsl2ShdslSpanConfCurrCondTargetMarginUp | 0 | 0 | This object specifies the upstream current condition target SNR margin for a SHDSL line. The SNR margin is the difference betwee… |
1.3.6.1.4.1.272.4.35.1.1.10.1.12 | hdsl2ShdslSpanConfWorstCaseTargetMarginUp | 0 | 0 | This object specifies the upstream worst case target SNR margin for a SHDSL line. The SNR margin is the difference between the d… |
1.3.6.1.4.1.272.4.35.1.1.10.1.13 | hdsl2ShdslSpanConfUsedTargetMargins | 0 | 0 | Contains indicates whether a target SNR margin is enabled or disabled. This is a bit-map of possible settings. The various bit … |
1.3.6.1.4.1.272.4.35.1.1.10.1.14 | hdsl2ShdslSpanConfReferenceClock | 0 | 0 | This object configures the clock reference for the STU-C in a SHDSL Line. |
1.3.6.1.4.1.272.4.35.1.1.10.1.15 | hdsl2ShdslSpanConfLineProbeEnable | 0 | 0 | This object enables/disables support for Line Probe of the units in a SHDSL line. When Line Probe is enabled, the system perform… |